USB4000 Optical bench Options

Grating Efficiency Curves Predicted Ranges & Resolution

Below are the Grating Efficiency Curves for gratingswith groove densities of 600, 1200, 1800 and 2400 mm Here are a series of graphs to demonstrate the range and opticalresolution (FWHM) of your USB4000 Spectrometer with a 25 µm slit.See our website for additional graphs of ranges and resolutions for every slit size.

-1

. See curves for all of our gratings atOceanOptics.com/Technical/GratingCharts.asp.

-1
Grating and 25-µm Slit 1200 mm
8070 60 50 40 3020 680670 660 650 640 630 620 610 600 590580 1.361.34 1.32 1.30 1.28 1.26 1.24 1.221.20 Example : If the startingwavelength is
#1#2 #3 #4 #14 250 nm , thenthe range is ~667 nm ,providing a 250-917 nm wavelength range and
RESOLUTION (nm) RELATIVE EFFICIENCY SPECTRALRANGE (nm) 1.34 nm
200 400 600 800 1000 1200 200 300 400 500 600 700 800 900 1000 resolution.
WAVELENGTH (nm) STARTINGWAVELENGTH (nm) Efficiency Curves for Gratings 1, 2, 3, 4 and 14.
-1
Grating and 25-µm Slit 1800 mm
8070 60 50 40 3020 350330 310 290 270 250 230 210 190 170150 Example :
0.650.60 0.55 0.50 0.450.400.350.30 If the startingwavelength is 350 nm , thenthe range is
#5#6 #9 ~310 nm ,providing a 350-660 nm wavelength range and
RESOLUTION (nm) RELATIVE EFFICIENCY SPECTRALRANGE (nm) 0.63 nm
200 400 600 800 1000 1200 200 300 400 500 600 700 800 900 1000 resolution.
WAVELENGTH (nm) STARTINGWAVELENGTH (nm) Efficiency Curves for Gratings 5, 6 and 9.
Spectrometers
Gratings with Groove Density of 1800 Gratings with Groove Density of 2400 Gratings with Groove Density of 1200 Gratings with Groove Density of 600600 mm
-1
Grating and 25-µm Slit 2400 mm
8070 60 50 40 3020 240220 200 180 160 140 120100 Example :
0.450.40 0.35 0.30 0.250.20 If the startingwavelength is 400 nm , thenthe range is
#10#11 ~190 nm ,providing a 400-590 nm wavelength range and
RESOLUTION (nm) RELATIVE EFFICIENCY SPECTRALRANGE (nm) 0.38 nm
200 400 600 800 1000 1200 200 300 400 500 600 700 800 resolution.
WAVELENGTH (nm) STARTINGWAVELENGTH (nm) Efficiency Curves for Gratings 10 and 11.
-1
Grating and 25-µm Slit
8070 60 50 40 3020 160150 140 130 1201101009080 0.320.30 0.28 0.26 0.24 0.22 0.200.18 0.16 Example : If the startingwavelength is 300 nm , thenthe range is
#7 #12 ~140 nm ,providing a 300-440 nm wavelength range and
RESOLUTION (nm) RELATIVE EFFICIENCY SPECTRALRANGE (nm) 0.29 nm
200 400 600 800 1000 1200 200 300 400 500 600 resolution.
WAVELENGTH (nm) STARTINGWAVELENGTH (nm) Efficiency Curves for Gratings 7 and 12.

oo oo

For all your sensing needs, visit OceanOptics.com18
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-196
pdf-page pdf di En 2008-12-49-05