| | | AIK onfloor installation trunking systems Ackermann I OBO | | |
| | | |
| | | 3ETTERMANN | | |
| | | |
| | | | | | | | | | | | | AIK onfloor installation trunking | | | | Preparations for installation | | Preparation of trunking base | | Connection of the trunking base | | | | | | | | | | | | |
| | | |
| | | The trunking is mounted on the existing floor, before the industrial floor covering is applied. The mounting surface must be clean and flat, in order to provide an interlocking connection of the trunking joints. Protective measure | | The trunking bases are completed by pushing onto the side profiles before fixing on the floor. | | For this, connect the joints by moving the side profiles so that they interlock. (Earth conductor clamp not contained in scope of delivery). Internal corner | | |
| | | |
| | | Direction changes | | |
| | | | |
| | | |
| | | For the protective measures, it is necessary to connect the individual trunking bases and side profiles using sufficiently dimensioned cables and earth conductor clamps. On insertion, the trunking divider automatically contacts with the base. External corner | | If there are right-angled directional changes in the course of the trunking, then the trunking basis must be adjusted to the appropriate angle situation. In the case of non-right-angled direction changes, the trun-king lids must also be modified. T-junction | | Right-angled trunking route as internal corner. | | |
| | | |
| | | T-junction with connection trunking | | |
| | | |
| | | With the T-junction, the trunking base is not included in the width of the junction trunking, although the rear side profile must completely bridge the reverse interruption. The junction trunking (AIK-F..), with the one-sided slope, is covered using internal corner lids. Floor covering work | | For junction trunking with a slope on both sides (AIK-A..), the AIKF/D-T lids are used together with the AIKA-AD connection lids. | | |
| | | Right-angled trunking route as external corner. | | |
| | | |
| | | |
| | | о о CL LU | | |
| | | Nominal trunking size 350 | | | Floor covering work, mounting lid | | |
| | | |
| | | |
| | | о о ÇN Й g о | | |
| | | |
| | | _ | | |
| | | |
| | | When laying the floor covering, ensure that it joins the trunking base. Cover the surface of the trunking lids completely with the floor covering. Pierce the floor covering on the lid fixing holes. Insert screws here and screw the lid to the trunking base. | | |
| | | For nominal trunking sizes of 350, support the lids with the TWL trunking divider. | | | For lids with installation or setup openings, the protective mounting lids are removed and, after application of the floor covering, the mounting openings are cut out cleanly. | | |
| | | |
| | | СО О | | |
| | | |
| | | |
| | | |
| | | Always indicate the article number when ordering. | | |
| | | UFS 129 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |