Protector ® Echo™ Filtered Fume Hoods - 2

Protector Echo Filtered Fume Hoods ® Labconco has combined its patented* fullyfeatured, containment-enhancing Protector® Hood design with Erlab’s GreenFumeHood® (GFH) Filtration Technology to deliver a multi-use fume hood that requires no ducting. The Protector® Echo™ Filtered Fume Hood delivers safety, energy savings and adaptability to ever-changing lab spaces. The Protector Echo Benchtop Filtered Fume Hood uses from four to ten Neutrodine Carbon Filters, depending on the hood’s width. Two Neutrodine Filters are stacked in each filtration column. Optional HEPA Filters are available to...

Open the catalog to page 2
Protector ® Echo™ Filtered Fume Hoods - 3

Protector Echo Filtered Fume Hoods ® of a filtered hood compared to a traditional ducted hood in various configurations. The greatest savings of a filtered hood is illustrated by the make-up air cost—the Protector Echo has none! In addition, the Protector Echo eliminates air pollutant emissions into the atmosphere. The Neutrodine Filter is made of plant-based carbon materials impregnated with neutral non-toxic agents. Once expended, the filters may be incinerated for environmentally-safe disposal. that allow the sash to be closed completely when electrical cords are plugged into the side...

Open the catalog to page 3
Protector ® Echo™ Filtered Fume Hoods - 4

Protector Echo Benchtop Filtered Fume Hoods ® • Sensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature. • Audible/visual alarms for breakthrough detection, temperature ≥40° C (104° F), fan failure and high sash position opening. At ≥60° C (140° F), all fans stop. • Three radio frequency identification (RFID) cards included: 9580901 User Card, 9580900 Administrator Card, and 9580902 Maintenance Card. Additional cards available upon request. • Power cord with plug. Or, may be hard wired to top-mounted boxes. All models...

Open the catalog to page 4
Protector ® Echo™ Filtered Fume Hoods - 5

Ordering Information Protector Echo™ Benchtop Filtered Fume Hoods ® Use this key to configure the nine digit catalog number to order your Protector Echo Benchtop Filtered Fume Hood. For example, a 180410002 is a 4' Protector Echo Benchtop Filtered Fume Hood with solid walls, with 100-115 volt, 50/60 Hz electrical requirements, two service fixtures and one GFCI electrical duplex receptacle. NOTE: Neutrodine Filters are required for operation and sold separately. See page 11. STEP 3. Select the Electrical Requirements, Service Fixtures and GFCI Electrical Duplex Receptacle combination you...

Open the catalog to page 5
Protector ® Echo™ Filtered Fume Hoods - 6

Dimensional Data Protector Echo™ Benchtop Filtered Fume Hoods ® 2.5" ID (6.4 cm) Utility pass-through opening 2.3" (5.8 cm) 3.7" (9.4 cm) 1.9" (4.8 cm) Single point internal field wired box, one on each side C Filtration column, (Neutrodine Filters sold separately) TOP Neutrodine Filters (sold separately) Interior service access 66.2" panel (168.1 cm) (one on each side on models 37.5" without side (95.3 cm) windows) Visibility (Back Window Models only) (Side Window Models only) 6 2.5" ID (6.4 cm) Utility pass-through opening 8-Ft Hood 1.7" (4.3 cm) Overhang from front of base cabinet and...

Open the catalog to page 6
Protector ® Echo™ Filtered Fume Hoods - 7

SpillStopper™ Work Surfaces Use this key to configure the seven digit catalog number to order your SpillStopper Dished Solid Epoxy Work Surface. For example, a 9501610 is a 6' wide x 36" deep SpillStopper Work Surface, with a left rear cupsink cutout. 1 STEP 3. Select a left cupsink cutout option (cupsink is sold separately). See dimensional drawing. This number is the sixth digit of your catalog number. STEP 1. Select the nominal width of your filtered fume hood. This number is the fifth digit of your catalog number. Shipping weight is noted for each width. 4 = 4' 6 = 6' 120 lbs. (54 kg)...

Open the catalog to page 7
Protector ® Echo™ Filtered Fume Hoods - 8

Protector Echo Floor-Mounted Filtered Fume Hoods ® • Built-in exhaust fans: 2 each per 4' model, 3 each per 5' model, 4 each per 6' model, and 5 each per 8' model to maintain 60 fpm face velocity at 16" sash opening height. • Sound pressure of <60 dB(A) with sash at operating height and <48 dB(A) with sash closed. • Sensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature. • Audible/visual alarms for breakthrough detection, temperature ≥40° C (104° F), fan failure and high sash position opening. At ≥60° C (140° F), all...

Open the catalog to page 8
Protector ® Echo™ Filtered Fume Hoods - 9

Use this key to configure the nine digit catalog number to order your Protector Echo Floor-Mounted Filtered Fume Hood. For example, a 183410002 is a 4' Protector Echo Floor-Mounted Filtered Fume Hood, with 100-115 volt, 50/60 Hz electrical requirements, two service fixtures and one GFCI electrical duplex receptacle. NOTE: Neutrodine Filters are required for operation and sold separately. See page 11. STEP 1. Select the width of your fume hood. This number is the fourth digit of your catalog number. 4 = 4' (122 cm) 6 = 6' (183 cm) STEP 2. Select the exterior depth of your fume hood. This...

Open the catalog to page 9
Protector ® Echo™ Filtered Fume Hoods - 10

Dimensional Data Protector Echo Floor-Mounted Filtered Fume Hoods ® 2.5" ID (6.4 cm) Utility pass-through opening 2.3" (5.8 cm) 2.5" ID (6.4 cm) Utility pass-through opening Single 2.3" (5.8 cm) point 3.7" internal (9.4 cm) field Single wired point 3.7" box, one internal (9.4 cm) 1.9" on each field (4.8 cm) side wired box, one 1.9" on each (4.8 cm) side C Filtration column, C (Neutrodine Filtration Filters sold column, separately) (Neutrodine Filters sold separately) 13.2" (33.5 cm) Working height opening 64.0" (162.6 cm) Upper sash open 64.0" height (162.6 cm) 63.6" Upper sash open (161....

Open the catalog to page 10
Protector ® Echo™ Filtered Fume Hoods - 11

Neutrodine® Filters by Erlab® Revolving Filter System The Neutrodine Filter is a comprehensive molecular filter that allows the simultaneous handling of solvents, acids, bases, ammonia and formaldehyde. Neutrodine Filters don't simply filter the molecules, they transform them! Erlab scientists view filtration technology from a different perspective—it's not just about the carbon. Neutrodine filters utilize multiple layers of technology to transform molecules, allowing the simultaneous adsorption of solvents, acids, and bases. Each filter is designed with a unique filter frame that prevents...