PdWEREDGË
Applications and Specifications
Remote Wireless Monitoring
Streamline operations with fleet optimization, preventative maintenance and remote diagnosis.
Rugged Metallic Stack Architecture
For industrial duty. Resistant to vibration and shocks up to 20 G's.
Remanufacturable stack maximizes your investment.
Low pressure system for optimum efficiency.
What About Hydrogen?
Nuvera has also created
the PowerTap Hydrogen Generator and Hydrogen Station, which allow for
quick and easy indoor or outdoor refueling. The Total Power Solution, featuring PowerEdge along with the PowerTap Hydrogen Generator and
Hydrogen Station, is the first set of hydrogen
products designed for material handling.
With only one vendor for
both power systems and hydrogen infrastructure, TPS offers ease of installation and service.
Water Neutral
No need to add or remove water _
during regular operation.
Field Tested Hardwareand Software
Extensively tested and proven design offers you peace of mind.
Steel Hydrogen Tanks
Offers quickest refueling option.**
** when used with PowerTap™
CounieiudldMie
Sealed, Maintenance-Free AGM Batteries
Extended high-power performance, full regen capacity and out-of-fuel return to base capability.
Lead counterweight. Meets minimum weight requirements in most truck models.
Product Specifications
Rated Power (30 sec)
25 kW
25 kW
31 kW
Voltage
36 VDC 36VDC 48 VDC
Operating Current Range 1
-50A to 1150A -400A to 1150A -280A to 1150A
Energy Storage Capacity 2
19.1 kWh 35.7 kWh 36.5 kWh
Size - in. (mm)
35.0 in. x 26.3 in. x 23.7 in. 38.2 in. x 31.4 in. x 23.7 in. (889 mm x 667 mm x 602 mm) (970 mm x 798 mm x 602 mm)
Target Weight - lbs (kg)
1850 lbs (839 kg) 3100 lbs (1406 kg)
Refueling Time
60 sec 120 sec
Hydrogen Storage
0.5 kg 1.0 kg
Hydrogen Pressure
5075 psig (350 bar)
Hydrogen Port
SAE J-2600 H35, CE 0036
Ambient Operating Temperature 3 25 to 95oF (-4 to 35oC)
Environment
Indoor Use Only
Emissions
Water Vapor
0
NUVERA
FUEL CELLS
PDWEREDEE
For more information, contact: Gus Block
Director of Marketing Nuvera Fuel Cells, Inc. 617.245.7553 gblock@nuvera.com www.nuvera.com
Notes 1: Actual Lower Limit is dependent on truck upper voltage threshold (value shown based on 44V) 2: Based on LHV of H2 at 5075 psi (350 bar),15oC and 1 hr battery discharge rate 3: System must be stored and started above freezing conditions (4oC, 39oF minimum)
03/09

pageCatalog pdf di En 2012-05-22-31