ANDROMEDA™ - Nuvera Fuel Cells - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for Nuvera Fuel Cells

Text version of the page
ANDRDMEOű
Product Specification*
i \
Passenger Cars and Trucks
Fleet Vehicles
Buses
Taxis
SpcClfiCdllOns
Stack Peak Power Stack Continuous Power Stack Operating Voltage Transient Response Stack Dimensions Stack Weight Stack Power Density
100kW ± 5(low pressure), 125kW ± 5(high pressure)
85kW ± 5(low pressure), 95kW ± 5(high pressure)
384 - 240V ± 15
10% - 90% < 2 sec
< 210 (height) x 550 x 900 mm
140kg ± 5kg
1,3 kW/l, 0.7 kW/kg @ peak power (low pressure) 1,6 kW/l, 1.0 kW/kg @ peak power (high pressure)
Type
Conductivity Flow Rate
Pressure Drop @ Rated Power Max Pressure T In Max T Out Max
Demi water or non-conductive heat transfer fluid*
< 5 pS/cm
148 1pm ± 10
600 mbar ± 100
4 bar absolute
62o C ± 2
70o C ± 2
NUVERA
FUEL CELLS
Type RH% In H2 Pressure
H2 Pressure Drop @ Rated Power
Oxidant
Hydrogen 5.5 Dry Hydrogen Input** 1,1 - 1,8 bar absolute 600 mbar ± 50
ANDROMEDA™
HCS-575 PEM Fuel Cell Stack Series
Type
RH% In Air Pressure
Air Pressure Drop @ Rated Power
Air
Dry Air
1,1 - 1,6 ± 100 mbar absolute 600 mbar ± 100
* Nuvera to verify fluid compatibility with stack materials ** Requires use of hydrogen recirculation pump
All specifications are specified at beginning of operational life. Specifications and descriptions in this document were in effect at the time of publication. Nuvera Fuel Cells, Inc. reserves the right to change specifications, product appearance, or product availability at any time.
Nuvera® is a registered trademark of Nuvera Fuel Cells, Inc. ©2007 Nuvera Fuel Cells, Inc.
For more information, contact:
William L. Mitchell
Nuvera Fuel Cells, Inc. mitchell.w@nuvera.com
www.nuvera.com
12/06

pageCatalog pdf di En 2012-05-22-31