for bourdon tube industrial pressure gauges, ELECTRONIC CONTACTS

direct wiring to PLC / PC direct input andto trigger optoelectronic coupler.Also they are the best preference for oil filled instruments to beinstalled in the most severe operating conditions created by theambient environments.

Electronic contacts with PNP output

Switching accuracy: 1,5 times the instrument accuracy. Switching hysteresis: 0,3...1% of full scale value. Adjustement: over an arc of 270 ° , through the knob placed onfront lens or through removable key. Open contactClosed contact Supply: 10...30 Vdc. Switching current: max 100 mA Temperature range: -25...+65 ° C Electronic contacts are equipped with electrical distancesensors (proximity sensors). The output signal is governedby the presence or absence of a control vane moved by the actual value pointer in the magnetic field of the proximity sensor.The switching behaviour of the PNP switches used in thesecontacts is normally defined as a “closer” (opposite to the inductive contacts). Due to their proximity type of switching, respect to the traditionalsliding contact they offer better switching accuracy and extended service life.They are properly designed to switch small DC load and soparticularly suitable for a WIRING SCHEME

(The numbers shown are the same as thoseindicated on the junction box)

FOR SINGLE CONTACTS... FOR DOUBLE CONTACTS... EX-CONTACT CODETHE PRESSURE RAISING MEANS...

- +- + +- 3 1 2

Opening contact

+- +- 3 1 2

Closing contact

E2E1E11 E22E12E21

+-
1 ° 2 °
-- 3 + + +- 3 4 1 2

Opening contact 1 ° Opening contact 2 °

(each contact must not exceed the next one)

+-
1 ° 2 °
-+- + +- 4 1 2

Opening contact 1 ° Closing contact 2 °

(each contact must not exceed the next one)

+-
1 ° 2 °
- 3 +- + +-

Closing contact 1 °

3 4 1 2

Opening contact 2 °

(each contact must not exceed the next one)

+-
1 ° 2 °
+- +- +- 4 1 2

Closing contact o 1 ° Closing contact 2 °

(each contact must not exceed the next one)

+-

-1-

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-324
pdf-page pdf di En 2008-12-49-02