Catalogue General Product Guide
www.nuovafima.com
print switch display
Page / 324
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
NUOVA FIMA - 149688, 2189, 208718, 4730
/ 324
See all the products NUOVA FIMA
Text version of the page

for bourdon tube pressure gauges,

MECHANICAL ELECTRIC CONTACTI

Magnetic Snap-Action Contacts

The electrical sliding contacts guarantee an accurate operationwithin a controlled hysteresis. However they are rather sensitiveto vibration, moreover, very slow pressure changes may cause an electric arc which can reduce its working life. This type of contact is universally used to guarantee the reliable operation of gauges under severe vibration. The magnetic action is guaranteed by a "click operation", which improves contactcapacity, life and is less sensitive to vibration. The required powerto overcome the magnetic resistance causes an hysteresis at set- point between 2% to 5% of full scale value.
Volt

Functional and constructive characteristics Functional and constructive characteristics

Set-point accuracy: 150% of instrument accuracy. Set-point accuracy:
100 mA200 mA 300 mA 400 mA120 mA240 mA 450 mA 600 mA65 mA130 mA 200 mA 250 mA 150% of instrument accuracy. Set-point hysteresys: 0,3% of full scale value. Set-point hysteresys: 2...5% of full scale value. Break rating: 10W/18VA. Break rating: 30W/50VA (20W/20VA for filled version). Maximum rating: 250Vac/0,7A (ohmic load). Maximum rating: 250Vac/1A (ohmic load). Contact material: Silver-Nickel 80/20%. Contact material: Silver-Nickel 80/20%. Contact setting:
Volt over an arc of 270 ° , by a fixed key fitted to thefront lens or by a removable key. Contact setting: over an arc of 270 ° , by a fixed key fitted to thefront lens or by a removable key. Electrical wiring: junction box as per VDE, see table at page 4. Electrical wiring: junction box as per VDE, see table at page 4.
Volt 22011048 24

LOAD RATINGS

40 mA80 mA120 mA 200 mA45 mA90 mA170 mA 350 mA25 mA45 mA 70 mA100 mA (1)

LOAD RATINGS

(1)
DCACInductive load DCACInductive load 22011048 24 Vdc Minimum values : 24Vdc/20mA. Vdc Minimum values : 24Vdc/20mA. liquid filled pressure gauges We recommand the use of control relays as they increase the working life of all types of contacts. For intrinsecally safe applications anapproppriate barrier must be used.
65 mA130 mA 190 mA 250 mA90 mA180 mA 330 mA 450 mA40 mA85 mA130 mA 150 mA CCCAInductive load 22011048 24 Vdc Minimum values : 24Vdc/20mA.(1) as per DIN 16085.

CONTROL RELAYS Sliding contacts -1-

ISO 9001 : 2000Cert. no. 0433/2
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-324
pdf-page pdf di En 2008-12-49-02