Catalogue Fieldbus Electronics and I/O
www.numatics.com
print switch display
Page / 76
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
NUMATICS - 85526, 42596
/ 76
See other catalogues for NUMATICS
Text version of the page
G2-1 Electronics
How to Order
1) Assembly Kit Selection
AKC
Electrical / Electronic-
Type & Location
STD = DRM = MUF = DWM= A01 =
D01 =
D03 =
F01 =
A17 =
Standard
DIN Rail Mounting (Std. 35mm)
Muffler in End Plates
DIN Rail with MUF
25 Pin Sub-D 16 Discrete
Outputs Sinking (NPN)
A01 + DRM
A01 + MUF
A01 + DRM + MUF
25 Pin Sub-D 16 I/O Points
Inputs Sourcing (PNP)
Outputs Sinking (NPN)
A17 + DRM
A17 + MUF
A17 + DRM + MUF
Valve Series-
6 = 2002 Series D= 2004 Series
Number of Valve Stations*
A
=
1
I =
9
Q =
17
B
=
2
J =
10
R =
18
c
=
3
K =
11
S =
19
D
=
4
L =
12
T =
20
E
=
en
M =
13
u =
21
TI
=
6
N =
14
v =
22
G
=
7
o =
15
w =
23
H
=
8
P =
16
x =
24
D18 D19 F07
Port Type
L = Push In
D = Barbed Fitting
* Maximum number of valve stations is determined by the combination of single and double Z-Boards types installed in the manifold sub-bases.
2) Valve Model Number Selection Valve model number with plug-in manifold base.
End Plate Port Size
1/4
8mm (5/16)
2 H
E02
3) Electronic Interface
Valve Series
6 = 2002 Series
D = 2004 Series
E02 = Separate Power
(Valve and I/O) G08 = With MCM if Not Standard (DN only) G20 = Without MCM if Not
Standard (PB & PT only)
Fieldbus Protocols DN = DeviceNet™ AB = Allen Bradley RIO PB = Profibus DP 1.5 MBps PT = Profibus DP 12 MBps DL = DeviceLogix
= 24 VDC
I/O Type
D = Digital
Number of-
Discrete Inputs**
Number of-
Discrete Outputs**
**4) I/O Per I/O Station - Electronic Interface Option Only (See I/O table below)
When ordering up to eight (8) I/O you must order one (1) Master I/O (which contains two (2) points I/O itself). The balance required is made up of Slaves, two (2) points per I/O station (total 3 Slave modules). A maximum of sixteen (16) I/O points can be configured by using two (2) Master modules and six (6) Slave modules. Total number of discrete inputs plus total number of discrete outputs must be less than or equal to 16. (See I/O table below).
Input master modules can be used with Output Slave Modules.
Output master Modules can be used with Input Slave Modules.
Sub-D outputs and I/O types do not require additional master modules when used alone
I/O Table: Note 2 I/O per station
SINKING (NPN) or SOURCING (PNP) INPUT
HOUSING TYPE
SINKING (NPN) OUTPUT
Master Kit No. Slave Kit No.
239-1800 239-1801
239-1802 239-1803
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
9
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages: