| | | G2-1 Electronics | | |
| | | |
| | | How to Order 1) Assembly Kit Selection | | |
| | | AKC | | |
| | | |
| | | |
| | | Electrical / Electronic- Type & Location | | |
| | | STD = DRM = MUF = DWM= A01 = D01 = D03 = F01 = A17 = | | Standard DIN Rail Mounting (Std. 35mm) Muffler in End Plates DIN Rail with MUF 25 Pin Sub-D 16 Discrete Outputs Sinking (NPN) A01 + DRM A01 + MUF A01 + DRM + MUF 25 Pin Sub-D 16 I/O Points Inputs Sourcing (PNP) Outputs Sinking (NPN) A17 + DRM A17 + MUF A17 + DRM + MUF | | |
| | | |
| | | Valve Series- 6 = 2002 Series D= 2004 Series Number of Valve Stations* | | |
| | | |
| | | | | | | | | | | | | | | A | = | 1 | I = | 9 | Q = | 17 | | | | B | = | 2 | J = | 10 | R = | 18 | | | | c | = | 3 | K = | 11 | S = | 19 | | | | D | = | 4 | L = | 12 | T = | 20 | | | | E | = | en | M = | 13 | u = | 21 | | | | TI | = | 6 | N = | 14 | v = | 22 | | | | G | = | 7 | o = | 15 | w = | 23 | | | | H | = | 8 | P = | 16 | x = | 24 | | | | | | | | | | | | | | |
| | | |
| | | D18 D19 F07 | | |
| | | |
| | | |
| | | Port Type L = Push In D = Barbed Fitting | | |
| | | * Maximum number of valve stations is determined by the combination of single and double Z-Boards types installed in the manifold sub-bases. 2) Valve Model Number Selection Valve model number with plug-in manifold base. | | |
| | | |
| | | End Plate Port Size | | |
| | | |
| | | 1/4 8mm (5/16) | | |
| | | 2 H | | |
| | | |
| | | |
| | | |
| | | E02 | | |
| | | 3) Electronic Interface | | |
| | | |
| | | |
| | | Valve Series 6 = 2002 Series D = 2004 Series | | |
| | | E02 = Separate Power (Valve and I/O) G08 = With MCM if Not Standard (DN only) G20 = Without MCM if Not Standard (PB & PT only) | | |
| | | |
| | | Fieldbus Protocols DN = DeviceNet™ AB = Allen Bradley RIO PB = Profibus DP 1.5 MBps PT = Profibus DP 12 MBps DL = DeviceLogix | | |
| | | |
| | | = 24 VDC I/O Type D = Digital | | |
| | | |
| | | Number of- Discrete Inputs** | | |
| | | |
| | | |
| | | Number of- Discrete Outputs** **4) I/O Per I/O Station - Electronic Interface Option Only (See I/O table below) When ordering up to eight (8) I/O you must order one (1) Master I/O (which contains two (2) points I/O itself). The balance required is made up of Slaves, two (2) points per I/O station (total 3 Slave modules). A maximum of sixteen (16) I/O points can be configured by using two (2) Master modules and six (6) Slave modules. Total number of discrete inputs plus total number of discrete outputs must be less than or equal to 16. (See I/O table below). Input master modules can be used with Output Slave Modules. Output master Modules can be used with Input Slave Modules. Sub-D outputs and I/O types do not require additional master modules when used alone | | |
| | | |
| | | I/O Table: Note 2 I/O per station | | |
| | | |
| | | SINKING (NPN) or SOURCING (PNP) INPUT | | |
| | | HOUSING TYPE | | SINKING (NPN) OUTPUT | | |
| | | |
| | | |
| | | |
| | | Master Kit No. Slave Kit No. | | |
| | | 239-1800 239-1801 | | 239-1802 239-1803 | | |
| | | |
| | | Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com. | | |