| | Technical Data | |
| | ELECTRICAL DATA | VOLTAGE CURRENT | |
| | BUS Power | 11-25 VDC 0.025 amps. | |
| | Valve & Discrete I/O | 24 VDC +/- 10% 4 amps, maximum | |
| | | Single key 4 pin 12mm (Micro) connector | |
| | Communication Connector | Single key 5 pin 12 mm (Micro) connector | |
| | LED's | Module status, Network status, Ext fault & Aux power | |
| | OPERATING DATA | |
| | Temperature Range | +32' to +115' F (0' to +46' C) | |
| | Humidity | 95% relative humidity, non-condensing | |
| | Moisture | Designed to meet NEMA 4 / IP65 requirements | |
| | CONFIGURATION DATA | |
| | | Contains all communication electronics as well as short circuit protected driver circuitry for up to 24 valve solenoids. Supports auto-baud detection and auto-device replacement (ADR) feature. | |
| | Manual Configuration Module (MCM) | Optional module for use when a manual configuration method is preferred. | |
| | Maximum Valve Solenoid Outputs | 24 (2002 Series), 16 (2004 Series) | |
| | Maximum Discrete I/O Points | 16 | |
| | Numatics' DeviceNet modules features Polled, Change of State (COS), Cyclic and combinations message capability. | |
| | Electronic Data Sheet (EDS) file and technical manuals are available in the download section of the Numatics, Inc. web site at: www.numatics.com/fieldbus | |
| | | | |