nurnams
G2-1 Electronics
DeviceLogix
DeviceLogix is a Rockwell Automation technology that allows a DeviceNet node to be programmed to execute a sequence independently from the control for the main PLC/IPC. A DeviceLogix enabled DeviceNet node can be used in conjunction with a standard DeviceNet network, providing simple distributed control functionality. Additionally, it can also be used in a standalone application, without a network connection or PLC/IPC, to sequence industrial pneumatic valves and control I/O. Numatics has integrated this licensed technology into its DeviceNet compatible valve manifold series, which combine the functionality of a modular pneumatic valve system with integrated I/O.
Programming of the DeviceLogix enabled node is done using the industry standard DeviceNet commissioning software tool RSNetworx for DeviceNet for Rockwell Automation. The programming software features an easily understandable graphics environment where the users can simply "drag and drop" logic function blocks (i.e. AND, NAND, OR, NOR, XOR, XNOR, RS LATCHES, COUNTERS and TIMERS) onto a page and interconnect them to develop the required sequence, or ladder logic programming can be used to develop a sequence. The programmed sequence is downloaded to the node via the standard DeviceNet communication connection, thus multiple nodes can be programmed simultaneously on the same network.
Technical Data
ELECTRICAL DATA
VOLTAGE CURRENT
BUS Power
11-25 VDC 0.025 amps.
Valve & Discrete I/O
24 VDC +/- 10% 4 amps, maximum
Single key 4 pin 12mm (Micro) connector
Communication Connector
Single key 5 pin 12 mm (Micro) connector
LED's
Module status, Network status, Ext fault & Aux power and logic enabled
OPERATING DATA
Temperature Range
+32' to +115' F (0' to +46' C)
Humidity
95% relative humidity, non-condensing
Moisture
Designed to meet NEMA 4 / IP65 requirements
CONFIGURATION DATA
Contains all communication electronics as well as short circuit protected driver circuitry for up to 24 valve solenoids. Supports auto-baud detection and auto-device replacement (ADR) feature.
Manual Configuration Module (MCM)
Optional module for use when a manual configuration method is preferred.
Maximum Valve Solenoid Outputs
24 (2002 Series)
Maximum Discrete I/O Points
16
Numatics' DeviceNet modules features Polled, Change of State (COS), Cyclic and combinations message capability.
Electronic Data Sheet (EDS) file and technical manuals are available in the download section of the Numatics, Inc. web site at: www.numatics.com/fieldbus
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
4
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-76
pdf-page pdf di En 2008-12-49-05