| | ELECTRICAL DATA | VOLTAGE CURRENT | |
| | Node Power | 24 VDC +/- 10% 0.120 amps. | |
| | Valve & Discrete I/O | 24 VDC +/- 10% 8 amps, maximum | |
| | | | |
| | Communication Connector | 5 pin reverse key female (Micro) connector | |
| | LED's | Processor status, Network status, Industrial fuse integrity & Aux power status | |
| | OPERATING DATA | |
| | Temperature Range | -10' to +115' F (-23' to +46' C) | |
| | Humidity | 95% relative humidity, non-condensing | |
| | Moisture | Designed to meet NEMA 4 / IP65 requirements | |
| | CONFIGURATION DATA | |
| | | Contains all communication electronics as well as short circuit protected driver circuitry for up to 32 valve solenoids. | |
| | Manual Configuration Module (MCM) | Module containing DIP and rotary switches for setting device configuration data. To order without MCM, use option G20 in NX model number. Optional only when using a Class 2 Profibus DP Master. (Note: see ordering options page 27) | |
| | Maximum Valve Solenoid Outputs | 32 | |
| | Maximum Discrete I/O Points | Manual configurable with MCM (standard): Various combinations of 160 outputs & 96 Inputs Software configurable (optional): Various combination of 192 outputs and 96 inputs | |
| | NETWORK DATA | |
| | | Single reverse key 5 pin 12mm micro (female) | |
| | Diagnostics | Shorts & open load conditions from valve solenoid coils & discrete outputs are monitored | |
| | Special Features | Supports Class 2 Profibus DP Master with auto-configuration, and fail-safe device settings | |
| | | | |