| | ELECTRICAL DATA | VOLTAGE CURRENT | |
| | Node Power | 24V ± 10% 0.040 amps. | |
| | BUS Power | 11-25 VDC 0.025 amps. | |
| | Valve & Discrete I/O | 24 VDC +/- 10% 8 amps, maximum | |
| | | Single key 4 pin mini type (male) | |
| | Communication Connector | Single key 5 pin (Mini or Micro type) male | |
| | LED's | Module status, Network status, Industrial fuse integrity & Aux power status | |
| | OPERATING DATA | |
| | Temperature Range | -10' to +115' F (-23' to +46' C) | |
| | Humidity | 95% relative humidity, non-condensing | |
| | Moisture | Designed to meet NEMA 4 / IP65 requirements | |
| | CONFIGURATION DATA | |
| | Communication Module | Contains all communication electronics as well as short circuit protected driver circuitry for up to 32 valve solenoids. | |
| | Manual Configuration Module (MCM) | Optional module containing DIP and rotary switches manufacturer for setting device configuration data. Note: Use option "G08" in "NX" model number | |
| | Maximum Valve Solenoid Outputs | 32 | |
| | Maximum Discrete I/O Points | Software configurable (standard): Various combinations of 192 outputs & 96 inputs With optional manual configuration module: Various combinations of 160 outputs & 80 inputs | |
| | NETWORK DATA | |
| | Supported Baud Rates | 125 K Baud, 250 K Baud, 500 K Baud with Auto-Baud detection | |
| | Supported Connection Types | Polled, Cyclic, Change of State (COS) and Combination Message Capability | |
| | Bus Connector | Single keyway 5 pin mini or 12mm micro types (male) | |
| | Diagnostics | Shorts & open load conditions from valve solenoid coils & outputs are monitored | |
| | Special Features | Supports Auto-Device Replacement (ADR) | |
| | | | |