G2-2 Electronics
DeviceNet
DeviceNet is an open protocol bus communication system developed by Allen-Bradley based on Controller Area Network (CAN) technology. The governing body for DeviceNet is the Open DeviceNet Vendors Association (ODVA). The ODVA controls the DeviceNet specification and oversees product conformance testing.
Numatics G2-2 DeviceNet nodes are capable of addressing up to 192 output/96 input. They have been tested and approved for conformance by the ODVA.
More information about DeviceNet and the ODVA can be obtained from the following WEB site:
Open DeviceNet Vendors Association (ODVA) www.odva.org
Technical Data
Manual Configuration Module (optional)
Bus connector 5 Pin Mini (Standard)
Bus Connector 5 Pin 12mm Micro (Optional consult factory)
ELECTRICAL DATA
VOLTAGE CURRENT
Node Power
24V ± 10% 0.040 amps.
BUS Power
11-25 VDC 0.025 amps.
Valve & Discrete I/O
24 VDC +/- 10% 8 amps, maximum
Single key 4 pin mini type (male)
Communication Connector
Single key 5 pin (Mini or Micro type) male
LED's
Module status, Network status, Industrial fuse integrity & Aux power status
OPERATING DATA
Temperature Range
-10' to +115' F (-23' to +46' C)
Humidity
95% relative humidity, non-condensing
Moisture
Designed to meet NEMA 4 / IP65 requirements
CONFIGURATION DATA
Communication Module
Contains all communication electronics as well as short circuit protected driver circuitry for up to 32 valve solenoids.
Manual Configuration Module (MCM)
Optional module containing DIP and rotary switches manufacturer for setting device configuration data. Note: Use option "G08" in "NX" model number
Maximum Valve Solenoid Outputs
32
Maximum Discrete I/O Points
Software configurable (standard): Various combinations of 192 outputs & 96 inputs
With optional manual configuration module: Various combinations of 160 outputs & 80 inputs
NETWORK DATA
Supported Baud Rates
125 K Baud, 250 K Baud, 500 K Baud with Auto-Baud detection
Supported Connection Types
Polled, Cyclic, Change of State (COS) and Combination Message Capability
Bus Connector
Single keyway 5 pin mini or 12mm micro types (male)
Diagnostics
Shorts & open load conditions from valve solenoid coils & outputs are monitored
Special Features
Supports Auto-Device Replacement (ADR)
Electronic Data Sheet (EDS) file and technical manuals are available in the download section of the Numatics, Inc. web site at: www.numatics.com/fieldbus
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
20
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-76
pdf-page pdf di En 2008-12-49-05