Catalogue 2005 Series - Directional Control Valve Catalogs - Featuring Circuit Board Technology
www.numation.com
print switch display
Page / 52
Make a request   
NUMATICS - 6315
/ 52
See other catalogues for NUMATICS
Text version of the page
nurnams
2005 Series
5 Ported, 2 and 3 position, 4-way, Spool & Sleeve Cv: 0.56
Dual 3-Way Pack Spool Cv:0.56
• Solenoid air pilot actuated
• Low wattage plug-in - 1.0 watt for DC application
• DC solenoids polarity insensitive with surge suppression
• Plug together circuit boards eliminate internal wiring
• Integral recessed gaskets
• Interchangeable Push-in fittings to accommodate various tube sizes
• Simple conversion from internal to external pilot supply
• Modular plug-together Fieldbus electronics
• NEMA 4/IP65
single solenoid air pilot 2 position 4-way
double solenoid air pilot 2 position 4-way
14
4 2 12
4 2
14
12
51 3
51 3
double solenoid air pilot double solenoid air pilot 3 position 4-way 3 position 4-way
open center closed center
42
14
12
14
12
42
513
51 3
(B) (A) (A)
2 4 14
Kv wJ
(B) 12
double solenoid
2 position dual 3-way
"14(A)" & "12(B)" NO
3 1 5
(EB) (P) (EA)
double solenoid
2 position dual 3-way
"14(A)" & "12(B)" NC
(B) 12
(B) (A) (A)
2 4 14
3 (EB)
1
(P)
5 (EA)
(B) 2
(A) 4
rr
<w w
~fT
3 CE
3 (EB)
i
(P)
5 (EA)
double solenoid
2 position dual 3-way
"14(A)" NC, "12(B)" NO
(A) 14
Technical Data
VALVE DATA
ENGLISH
METRIC
Cv
Flow Capacity
Operating Pressure Range
Operating Pressure Range - 3 Way
Pilot Pressure Range
Pilot Pressure Range - 3 Way
Pilot Pressure Vacuum
Temperature Range (Ambient)
Operating Data
0.56
26 SCFM @ 80 PSIG upstream pressure to atmosphere 28" Hg. Vacuum to 150 PSIG 22" Hg. Vacuum to 100 PSIG
26 to 120 PSIG
26 to 100 PSIG
50 to 100 PSIG
-10T to +115T
0.56
552 Nl/m @ 6 bar upstream to 5 bar downstream Vacuum to 10 bar Vacuum to 7 bar 1.8 to 8.2 bar 1.8 to 7 bar 3.5 to 7 bar -23'C to +46'C
ALL SOLENOIDS ARE CONTINUOUS DUTY RATED
110-120 VAC / 50/60 Hz.
Power (Watts)
1.0
3.7
Holding Current (Amps)
0.04
0.04
RESPONSE TIME IN SECONDS
ENERGIZE
DE-ENERGIZE
ENERGIZE
DE-ENERGIZE
2 - Position, Single, Spring Return
0.014
0.016
0.014
0.016
2 - Position, Double, Detented
0.013
N/A
0.013
N/A
3 - Position, Spring Centered
0.014
0.016
0.014
0.016
Dual 3 Way
0.014
0.016
0.014
0.016
Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com.
4
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-52
pdf-page pdf di En 2008-10-42-13