See other catalogues for
Numatics Motion Control
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | G Series Rodless Cylinders | | |
| | | |
| | | G Series - G1 & G2 Locking Unit This is a spring to hold and air to release locking unit. After the cylinder has achieved the desired position, exhaust the air release signal and the locking force will be applied. If a greater locking force is required an air assist supply may be applied to the unit. | | |
| | | |
| | | Model Number Selection Chart | | |
| | | |
| | | MODEL NUMBER | | |
| | | BORE | | |
| | | |
| | | 25mm 32mm 40mm 50mm | | MKS1501A MKS1501A MKS2001A MKS2001A | | |
| | | |
| | | |
| | | Dimensions | | |
| | | |
| | | G1 SERIES | | G2 SERIES | | |
| | | BORE DIAMETER | | |
| | | |
| | | hw e h w e Note: For single rail 40 & 50 series bores, top and bottom plates are same as G2 | | |
| | | |
| | | |
| | | | | | | | | | | | | | 3.24 | 5.12 | 0.26 | 3.24 | 5.51 | 0.77 | | | | (82.3) | (130.0) | (6.7) | (82.3) | (140.0) | (19.5) | | | | 3.56 | 5.12 | 0.26 | 3.56 | 5.51 | 0.77 | | | | (90.5) | (130.0) | (6.7) | (90.5) | (140.0) | (19.5) | | | | 4.55 | 8.46 | 0.63 | 4.55 | 8.46 | 0.63 | | | | (115.5) | (215.0) | (16.0) | (115.5) | (215.0) | (16.0) | | | | 5.36 | 8.46 | 0.63 | 5.36 | 8.46 | 0.63 | | | | (136.2) | (215.0) | (16.0) | (136.2) | (215.0) | (16.0) | | | | | | | | | | | | | |
| | | 25mm 32mm 40mm 50mm | | |
| | | Gl | | |
| | | M5 FILTER | | |
| | | |
| | | |
| | | |
| | | |
| | | "E" | | |
| | | |
| | | BORE SPRING FORCE ONLY SPRING PLUS AIR SUPPLY FORCE | | |
| | | |
| | | 25mm 32mm 40mm 50mm | | 90 lbs (400 N) 90 lbs (400 N) 135 lbs (600 N) 135 lbs (600 N) | | 225 lbs (1000 N) @ 87 PSI (6 Bar) 225 lbs (1000 N) @ 87 PSI (6 Bar) 337 lbs (1500 N) @ 87 PSI (6 Bar) 337 lbs (1500 N) @ 87 PSI (6 Bar) | | |
| | | G2 | | |
| | | |
| | | |
| | | |
| | | Plus Connection: by use of a 5/3 valve plus connection is made by removing M5 Alter and replacing with second connection Air Requirements: Clean lubricated air supply opening pressure 80PSI (5.5) Bar. Max pressure 87PSI (6) Bar Note: To connect the air signal for additional holding force remove the factory installed vent/filter plug and replace with a holding pressure supply. The holding pressure supply should be present only when the unit is in the desired position and the release signal is exhausted. Locking units are a static device not dynamic. Locking units are not a load unit with use of locking unit long carriage cylinders will have medium carriage loads Installation Locking units are factory installed and utilize the G1 or G2 Series long carriage. The locking unit is installed in place of the middle bearing slider. Ordering Information Select the appropriate bore size in the G1 or G2 Series Rodless cylinder with a long carriage and insert one of the following suffixes in the 13th and 14th "Options" spaces. OL Locking Unit only ML Locking unit and Switch Magnets | | |
| | | |
| | | Information subject to change without notice. For ordering information or regarding your local sales office visit www.numatics.com. | | |
| | | 19 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |