V60-63 Series - Norgren - #4

/ 20


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
Pages:


See other catalogues for Norgren

Text version of the page

V60-63

2 x 3/2 directional control valves, solenoid actuated

SymbolModelPort sizePilot exhaustPilot supplySolenoidvariantFlow (l/min)Operatingpressure (bar)Pilot pressure(bar)Dimensionaldrawing no.kg V60AA11A-Ax***G1/8 Internal Not collected 1 500 2 ... 8 – 0,34 7 V60AA11D-Cx13AG1/8 Internal Collected 2 500 2 ... 10 – 0,24 8
1441051102123 V61BA11A-Ax***G1/4 Internal Not collected 1 950 2 ... 8 – 0,43 7 V61BA11D-Cx13AG1/4 Internal Collected 2 950 2 ... 10 – 0,33 8 NC/NCNO/NONO/NC V62CA11A-Ax***G3/8 Internal Not collected 1 1900 2 ... 8 – 0,73 7 V62CA11D-Cx13AG3/8 Internal Collected 2 1900 2 ... 10 – 0,63 8 V60AB11A-Ax***G1/8 Internal Not collected 1 500 2 ... 8 – 0,34 7
1041451123210 V60AB11D-Cx13AG1/8 Internal Collected 2 500 2 ... 10 – 0,24 8 V61BB11A-Ax***G1/4 Internal Not collected 1 950 2 ... 8 – 0,43 7 V61BB11D-Cx13AG1/4 Internal Collected 2 950 2 ... 10 – 0,33 8 V62CB11A-Ax***G3/8 Internal Not collected 1 1900 2 ... 8 – 0,73 7 V62CB11D-Cx13AG3/8 Internal Collected 2 1900 2 ... 10 – 0,63 8 V60AC11A-Ax***G1/8 Internal Not collected 1 500 2 ... 8 – 0,34 7
1041451102123 V60AC11D-Cx13AG1/8 Internal Collected 2 500 2 ... 10 – 0,24 8 V61BC11A-Ax***G1/4 Internal Not collected 1 950 2 ... 8 – 0,43 7 V61BC11D-Cx13AG1/4 Internal Collected 2 950 2 ... 10 – 0,33 8 V62CC11A-Ax***G3/8 Internal Not collected 1 1900 2 ... 8 – 0,73 7 V62CC11D-Cx13AG3/8 Internal Collected 2 1900 2 ... 10 – 0,63 8
*** Insert coil code from table below or 000 for version without solenoid. For manual override options, substitute ‘x’ as follows: 1 = without manual override, 2 = push and lock, 3 = push only NC/NC = Both valves normally closed (port P) NO/NO = Both valves normally open (port P) NO/NC = 1 valve normally open, 1 valve normally closed (port P)

Coil & voltage codes

Solenoid variant 1 (solenoid rotates 4 x 90°)

22 mm coil DIN EN 175 301-803 (DIN 43650 B)22 mm coil industrial standard

Voltage Coil code Power inrush/holdModel Voltage Coil code Power inrush/holdModel 12 V d.c. 12L 2 W V10626-A12L 12 V d.c. 12J 2 W QM/48/12J/21 24 V d.c. 13L 2 W V10626-A13L 24 V d.c. 13J 2 W QM/48/13J/21 24 V 50/60 Hz 14L 4/2,5 VA V10626-A14L 24 V 50/60 Hz 14J 4/2,5 VA QM/48/14J/21 48 V 50/60 Hz 16L 4/2,5 VA V10626-A16L 48 V 50/60 Hz 16J 4/2,5 VA QM/48/16J/21 110/120 V 50/60 Hz 18L 4/2,5 VA V10626-A18L 110/120 V 50/60 Hz 18J 4/2,5 VA QM/48/18J/21 220/240 V 50/60 Hz 19L 6/5 VA V10626-A19L 220/240 V 50/60 Hz 19J 6/5 VA QM/48/19J/21

Solenoid variant 2

Double solenoid DIN EN 175 301-803 (DIN 43650 type C) 4 pin

Electrical detailsPlug configuration, valve side/twin pilot

Voltage Coil code Power inrush/holdManual overrideModel Voltage tolerance:±10% 24 V d.c. 13 A 2 W Push only 9031703900002400 Rating:100% E.D. 24 V d.c. 13 A 2 W Turn & lock 9031704900002400 Protection class:IP 65 with sealed plugs (ISO 6952) 24 V d.c. 13 A 2 W Without 9031705900002400 Connector plugs must be ordered separately – see page 16 Symbol Plug no. FunctionActuation 1(+)12 (Solenoid 2)
123 2(–)12 + 14 3(+)14 (Solenoid 1)

N/UK 5.4. 314.04

Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

5/02


pageCatalog pdf di En 2012-02-06-12