You may also be interested in
Air filter, Blow gun, Rotary cylinder, Diaphragm solenoid valve, Pneumatic fitting
Text version of the page
V60-632 x 3/2 directional control valves, solenoid actuatedSymbolModelPort sizePilot exhaustPilot supplySolenoidvariantFlow (l/min)Operatingpressure (bar)Pilot pressure(bar)Dimensionaldrawing no.kg V60AA11A-Ax***G1/8 Internal Not collected 1 500 2 ... 8 0,34 7 V60AA11D-Cx13AG1/8 Internal Collected 2 500 2 ... 10 0,24 81441051102123 V61BA11A-Ax***G1/4 Internal Not collected 1 950 2 ... 8 0,43 7 V61BA11D-Cx13AG1/4 Internal Collected 2 950 2 ... 10 0,33 8 NC/NCNO/NONO/NC V62CA11A-Ax***G3/8 Internal Not collected 1 1900 2 ... 8 0,73 7 V62CA11D-Cx13AG3/8 Internal Collected 2 1900 2 ... 10 0,63 8 V60AB11A-Ax***G1/8 Internal Not collected 1 500 2 ... 8 0,34 7 1041451123210 V60AB11D-Cx13AG1/8 Internal Collected 2 500 2 ... 10 0,24 8 V61BB11A-Ax***G1/4 Internal Not collected 1 950 2 ... 8 0,43 7 V61BB11D-Cx13AG1/4 Internal Collected 2 950 2 ... 10 0,33 8 V62CB11A-Ax***G3/8 Internal Not collected 1 1900 2 ... 8 0,73 7 V62CB11D-Cx13AG3/8 Internal Collected 2 1900 2 ... 10 0,63 8 V60AC11A-Ax***G1/8 Internal Not collected 1 500 2 ... 8 0,34 7 1041451102123 V60AC11D-Cx13AG1/8 Internal Collected 2 500 2 ... 10 0,24 8 V61BC11A-Ax***G1/4 Internal Not collected 1 950 2 ... 8 0,43 7 V61BC11D-Cx13AG1/4 Internal Collected 2 950 2 ... 10 0,33 8 V62CC11A-Ax***G3/8 Internal Not collected 1 1900 2 ... 8 0,73 7 V62CC11D-Cx13AG3/8 Internal Collected 2 1900 2 ... 10 0,63 8 *** Insert coil code from table below or 000 for version without solenoid. For manual override options, substitute x as follows: 1 = without manual override, 2 = push and lock, 3 = push only NC/NC = Both valves normally closed (port P) NO/NO = Both valves normally open (port P) NO/NC = 1 valve normally open, 1 valve normally closed (port P) Coil & voltage codesSolenoid variant 1 (solenoid rotates 4 x 90°)22 mm coil DIN EN 175 301-803 (DIN 43650 B)22 mm coil industrial standardVoltage Coil code Power inrush/holdModel Voltage Coil code Power inrush/holdModel 12 V d.c. 12L 2 W V10626-A12L 12 V d.c. 12J 2 W QM/48/12J/21 24 V d.c. 13L 2 W V10626-A13L 24 V d.c. 13J 2 W QM/48/13J/21 24 V 50/60 Hz 14L 4/2,5 VA V10626-A14L 24 V 50/60 Hz 14J 4/2,5 VA QM/48/14J/21 48 V 50/60 Hz 16L 4/2,5 VA V10626-A16L 48 V 50/60 Hz 16J 4/2,5 VA QM/48/16J/21 110/120 V 50/60 Hz 18L 4/2,5 VA V10626-A18L 110/120 V 50/60 Hz 18J 4/2,5 VA QM/48/18J/21 220/240 V 50/60 Hz 19L 6/5 VA V10626-A19L 220/240 V 50/60 Hz 19J 6/5 VA QM/48/19J/21Solenoid variant 2Double solenoid DIN EN 175 301-803 (DIN 43650 type C) 4 pinElectrical detailsPlug configuration, valve side/twin pilotVoltage Coil code Power inrush/holdManual overrideModel Voltage tolerance:±10% 24 V d.c. 13 A 2 W Push only 9031703900002400 Rating:100% E.D. 24 V d.c. 13 A 2 W Turn & lock 9031704900002400 Protection class:IP 65 with sealed plugs (ISO 6952) 24 V d.c. 13 A 2 W Without 9031705900002400 Connector plugs must be ordered separately see page 16 Symbol Plug no. FunctionActuation 1(+)12 (Solenoid 2)123 2()12 + 14 3(+)14 (Solenoid 1) N/UK 5.4. 314.04Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.5/02 |
|