V60-63
3/2 directional control valves, solenoid actuated
Symbol
Model
Port size Pilot supply
Pilot exhaust
Solenoid
Flow (l/min)
Operating
Pilot pressure
kg
Dimensional
variant
pressure (bar)
(bar)
drawing no.
12 2,
V60A413A-AX***
G1/8
Internal
Not collected
750
2 ... 8
-
0,22
M> LM .
V60A423A-AX***
G1/8
External
Not collected
750
-0,9 ... 8
3 ... 8
0,22
3 1
V60A413D-CX13A
G1/8
Internal
Collected
750
2 ... 10
-
0,21
V60A423D-CX13A
G1/8
External
Collected
750
-0,9 ... 10
3 ... 10
0,21
NC
V61B413A-AX***
G1/4
Internal
Not collected
1300
2 ... 8
-
0,29
V61B423A-AX***
G1/4
External
Not collected
1300
-0,9 ... 8
3 ... 8
0,29
V61B413D-CX13A
G1/4
Internal
Collected
1300
2 ... 10
-
0,27
V61B423D-CX13A
G1/4
External
Collected
1300
-0,9 ... 10
3 ... 10
0,27
V62C413A-AX***
G3/8
Internal
Not collected
2600
2 ... 8
-
0,52
V62C423A-AX***
G3/8
External
Not collected
2600
-0,9 ... 8
3 ... 8
0,52
V62C413D-CX13A
G3/8
Internal
Collected
2600
2 ... 10
-
0,50
4
V62C423D-CX13A
G3/8
External
Collected
2600
-0,9 ... 10
3 ... 10
0,50
4
V63D413A-AX***
G1/2
Internal
Not collected
4200
2 ... 8
-
0,78
5
V63D423A-AX***
G1/2
External
Not collected
4200
-0,9 ... 8
3 ... 8
0,78
5
V60A313A-AX***
G1/8
Internal
Not collected
750
2 ... 8
-
0,22
2
HTT
B -
V60A323A-AX***
G1/8
External
Not collected
750
-0,9 ... 8
3 ... 8
0,22
2
3
V60A313D-CX13A
G1/8
Internal
Collected
750
2 ... 10
-
0,21
4
V60A323D-CX13A
G1/8
External
Collected
750
-0,9 ... 10
3 ... 10
0,21
4
NO
V61B313A-AX***
G1/4
Internal
Not collected
1300
2 ... 8
-
0,29
2
V61B323A-AX***
G1/4
External
Not collected
1300
-0,9 ... 8
3 ... 8
0,29
2
V61B313D-CX13A
G1/4
Internal
Collected
1300
2 ... 10
-
0,27
4
V61B323D-CX13A
G1/4
External
Collected
1300
-0,9 ... 10
3 ... 10
0,27
4
V62C313A-AX***
G3/8
Internal
Not collected
2600
2 ... 8
-
0,52
2
V62C323A-AX***
G3/8
External
Not collected
2600
-0,9 ... 8
3 ... 8
0,52
2
V62C313D-CX13A
G3/8
Internal
Collected
2600
2 ... 10
-
0,50
4
V62C323D-CX13A
G3/8
External
Collected
2600
-0,9 ... 10
3 ... 10
0,50
4
V63D313A-AX***
G1/2
Internal
Not collected
4200
2 ... 8
-
0,78
5
V63D323A-AX***
G1/2
External
Not collected
4200
-0,9 ... 8
3 ... 8
0,78
5
10
V60A411A-AX***
G1/8
Internal
Not collected
750
1,5 ... 8
-
0,30
3
333"
V60A422A-AX***
G1/8
External
Not collected
750
-0,9 ... 8
3 ... 8
0,30
3
3
- -1
V60A411D-CX13A
G1/8
Internal
Collected
750
1,5 ... 10
-
0,20
4
V60A422D-CX13A
G1/8
External
Collected
750
-0,9 ... 10
3 ... 10
0,20
4
V61B411A-AX***
G1/4
Internal
Not collected
1300
1,5 ... 8
-
0,38
3
V61B422A-AX***
G1/4
External
Not collected
1300
-0,9 ... 8
3 ... 8
0,38
3
V61B411D-CX13A
G1/4
Internal
Collected
1300
1,5 ... 10
-
0,27
4
V61B422D-CX13A
G1/4
External
Collected
1300
-0,9 ... 10
3 ... 10
0,27
4
V62C411A-AX***
G3/8
Internal
Not collected
2600
1,5 ... 8
-
0,61
3
V62C422A-AX***
G3/8
External
Not collected
2600
-0,9 ... 8
3 ... 8
0,61
3
V62C411D-CX13A
G3/8
Internal
Collected
2600
1,5 ... 10
-
0,50
4
V62C422D-CX13A
G3/8
External
Collected
2600
-0,9 ... 10
3 ... 10
0,50
4
V63D411A-AX***
G1/2
Internal
Not collected
4200
1,5 ... 8
-
0,87
6
V63D422A-AX***
G1/2
External
Not collected
4200
-0,9 ... 8
3 ... 8
0,87
6
*** Insert coil code from table below or 000 for version without solenoid. For manual override options, substitute 'x' as follows: 1 = without manual override, 2 = push and lock, 3
= push only
Coil & voltage codes
NC = Normally closed
NO = Normally open
Solenoid variant 1 (solenoid rotates 4 x 90°)
22 mm coil DIN EN 175 301-803 (DIN 43650 B)
22 mm coil industrial standard
Voltage
Coil code
Power inrush/hold Model
Voltage
Coil code
Power inrush/hold
Model
12 V d.c.
12L
2 W
V10626-A12L
12 V d.c.
12J
2 W
QM/48/12J/21
24 V d.c.
13L
2 W
V10626-A13L
24 V d.c.
13J
2 W
QM/48/13J/21
24 V 50/60 Hz
14L
4/2,5 VA
V10626-A14L
24 V 50/60 Hz
14J
4/2,5 VA
QM/48/14J/21
48 V 50/60 Hz
16L
4/2,5 VA
V10626-A16L
48 V 50/60 Hz
16J
4/2,5 VA
QM/48/16J/21
110/120 V 50/60 Hz
18L
4/2,5 VA
V10626-A18L
110/120 V 50/60 Hz
18J
4/2,5 VA
QM/48/18J/21
220/240 V 50/60 Hz
19L
6/5 VA
V10626-A19L
220/240 V 50/60 Hz
19J
6/5 VA
QM/48/19J/21
Solenoid variant 2
Double solenoid DIN EN 175 301-803 (DIN 43650 type C) 4 pin
Electrical details
Voltage
Coil code
Power inrush/hold
Manual override
Model
24 V d.c.
13 A
2 W
Push only
9031703900002400
24 V d.c.
13 A
2 W
Turn & lock
9031704900002400
24 V d.c.
13 A
2 W
Without
9031705900002400
Voltage tolerance: ±10%
Rating:
100% E.D.
Protection class: IP 65 with sealed plugs (ISO 6952)_
Plug configuration, valve side/twin pilot
Symbol Plug no. Function Actuation
1 (+) 12 (Solenoid 2)
Connection plugs must be ordered separately - see page 16
\\2 0 1\\
2
(-)
12 + 14
3
(+)
14 (Solenoid 1)
N/UK 5.4.314.02
5/02
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.