UNIVERSAL Worm gear units Technical Explanations
info
NORD AC Motors
The motors of the IEC AC motor modules are fan-cooled 4-pole squirrel cage rotor motors with a three phase design. Theyare suitable for mains operation as well as for inverter operation. The AC motors have standard IEC-B14 flanges.
Upon request, B5 flange, single phase motors, 2, 6, 8-pole motors, pole-changing motors, integrated rotaryencoder, forced cooling fan, ATEX and CUS/UL conforming motors and others are also available. Please request the motor catalogue M7000.
Motors that fall under the specifcation area of CEMEP agreement fulfill efficiencyclass EFF2. The following standards are used by NORD AC motors.
Technical Data of the IEC AC Motor Module with 400V/50Hz
Type
p1
[kW]
ni [min 1]
IN
[A]
cos (p
MN
[Nm]
MA/MN
M^Mn
IA/IN
J
[gm2]
63S/4 63L/4
0.12 0.18
1335 1350
0.50 0.62
0.89 0.80
0.86 1.30
1.8 1.8
1.9 1.9
2.5 2.6
0.21 0.28
71S/4 71L/4
0.25 0.37
1380 1380
0.76 1.10
0.77 0.75
1.73 2.60
2.2 2.1
2.1 2.3
3.3 3.2
0.63 0.76
80S/4 80L/4
0.55
0.75
1375 1375
1.52 2.10
0.73 0.74
3.82 5.21
1.9 2.0
2.0 2.1
3.3 3.5
1.28 1.65
90S/4 90L/4
1.10 1.50
1395 1395
2.81 3.55
0.74 0.78
7.53 10.30
3.2 3.1
3.4 3.6
5.0 5.4
2.82 3.60
100L/4
100LA4
2.20 3.00
1440 1415
5.22 6.54
0.74 0.80
14.60 20.20
2.3 2.5
3.0 2.9
5.1 5.4
4.50 6.00
I12M/4
4.00
1445
8.30
0.80
26.40
2.3
2.8
5.3
11.90
IEC 60 034-1 (DIN EN 60 034-1) IEC 60 034-5 (DIN EN 60 034-5) IEC 60 034-6 (DIN EN 60 034-6) IEC 60 034-8 (DIN EN 60 034-8)
IEC 60 034-9 (DIN EN 60 034-9) IEC 60 034-11 (DIN EN 60 034-11 )
IEC 60 034-14 (DIN EN 60 034-14) IEC 60 038 (DIN EN 60 038)
■ General terms and conditions
■ Enclosures
■ Types of cooling
■ Connection name & rotation direction
■ Noise limit value
■ Built-in thermal contacts Protection
■ Mechanical vibration
■ IEC standard voltage
Operating Mode: Enclosure: Insulation Material
Class:
Voltages:
S1 (continuous operation)
IP 55 F
A230V/Y400V at 50Hz and Y460V at 60Hz
A400V/Y690V at 50Hz and 460V at 60Hz P1: Rated Power; n1: Rated Speed;
lN : Rated Current; MN: Rated Torque;
MA: Start-up Torque; MK: Stalling Torque;
cos cp: Power Factor; J: Mass Moments of Inertia
NORD
There are also motors of the IEC AC motor module with brakes. The brake motors are marked with the symbol £T} in the selection list and in the dimension section. The NORD brake motors are NORD AC motors with integrated electromagnetic spring force brakes. The brake release is performed bythe DC electro­magnets, and in case there is power failure because of the pressure springs, the application of the brakes is carried out. The ring setting gauge enables a stepless reduction of the braking torque of up to 50%.
The standard brake coil current is 205V and 180V DC. Consequently, the built-in rectifier in the terminal box allows the brake to connect to the AC motor power supply A230V/Y400V AC or A400V/Y690V AC.
Upon request, other coil voltages, other brake torques, higher enclosures, dust protection rings, stainless steel friction plates, manual release levers and other options are available. Please request the motor catalogue M7000.
Motors
Technical Data for Brake Motor Brakes
Type
MB
P20
Wmax
a
[Nm]
[W]
[J]
[mm]
63S/4 BRE5
5
22
3000
0.2
63L/4 BRE5
71S/4 BRE5
LO
22
3000
0.2
71L/4 BRE5
80S/4 BRE5
5
22
3000
0.2
80L/4 BRE10
10
28
6000
0.2
90S/4 BRE10
10
28
6000
0.2
90L/4 BRE20
20
39
12000
0.2
100L/4BRE20
20
39
12000
0.2
I00LA/4BRE40
40
42
25000
0.3
I12M/4BRE40
40
42
25000
0.3
Enclosure:
IP 55
Coil voltage: 205V DC suitable for A230V/Y400V AC
180V DC suitable for 400V/Y690V AC
MB: Brake Torque; P20: Coil Power;
Wmax: max. friction work for each clearance at n = ca. 1400 min-1; a: Nominal Clearance
G 1035 www.nord.com
13
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-106
pdf-page pdf di En 2008-12-49-05