Thefollowing information may help in selecting the appropriate measuring device for your needs.

Accuracy

The precision of the instrument which can be reported in three ways.1.By quoting the guaranteed tolerance as a percentage of the reading or indicated value,(eg.0.5% of Reading). 2.By quoting the guaranteed tolerance as a percentage of the full scale value of the instrument,(eg.0.1% FS or 0.1% FSD).3.By quoting a class of device in accordance with BS7882:1997 Method for calibration and classification of torque industrial measuring devices.(See page 84).

Modes of Operation

First Peak of Torque

-when a click type industrial torque wrench signals that the set torque has been achieved,the applied torque will momentarily drop before climbing again.Generally the fastener stops rotating at point 1,and from a standstill,the breakaway torque to achieve further rotation of the fastener will be higher than point 3b.Only if the operator is very insensitive to the break point will the final tightening effort be incorrect.First Peak of Torque mode will detect the break point of the torque wrench,not thehighest torque applied. 1=Torque wrench activates2=Click heard 3a = Wrench released quickly 3b = Wrench released slowly

Peak Torque

-this mode of operation will record the highest torque applied.In thecase of a click type torque wrench this may be higher than the actual break point if thewrench continues to be loaded beyond the break.Consequently,Peak Torque is more useful for calibrating devices without a break signal such as dial or electronic wrenches.

Track

-this mode has no memoryat all.When the load is removed the display will return to zero.Track is used for calibrating the device itself or for monitoring a fluctuating torque.

Resolution

The smallest measurement interval that can be determined on the indicating device.This applies to analogue and digital devices.

Number of Digits

Digital displays are described as having a certain number of digits or active digits. Half digits can be used to increase the resolution of a device without the expense of going to an additional full active digit.Eg 1.1000 N.m displayed on a 4 digit system would read 1000 (resolution = 1 N.m). Eg 2.1000 N.m displayed on a 4
1
2 digit system would read 1000.0 (resolution = 0.1 N.m).Active digits change as the torque changes.Non active digits only assist in showing the magnitude of the torque.For example,10,000 N.m requires 5 digits to display its magnitude.Eg 3.With 4 activedigits (and 1 passivedigit),10,000 N.m would change in steps of 10 N.m. Eg 4.With 4
1
2 or 5 active digits,10,000 N.m would change in steps of 1 N.m.

Signal Processing

Electronic Circuitry falls broadly into two types,analogue and digital,with most electronic measurement systemscomprising a mixtureof the two.There are also whole analogue electronic systems,but these are rare in torque measurement.Most systems start with an analogue signal.The point at which the signal is converted defines the type.Analogue systems one in which the signal is processed before being converted to digital. Digital systems the original analogue signal is converted to digital before processing.

58

Norbar
-your key to torque control
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-12-49-05