|
catalogue search
|
You may also be interested in
Power distribution cable, Wiring harness, Low-voltage cable, Medium voltage cable, Power distribution
Text version of the page
PoÄet a prĹŻĹez il(mm Tvarjádra PrĹŻmÄr inf.(mm) Hmotnost inf.(kg/km) PolomÄr ohybu(mm) Äinný odpor ( Ekvivalentnízkrat.proud(kA) Äasová otep-lovací konst.(sec) Zatiitelnostna vzduchu(A) IndukÄnost (mH/km) Min.pevnostjádra v tahu( Obsah Cu(kg/km)
2 ) ⌠/km) N ) No.of cores(mm Shape of the conductor Diameterappr.(mm) Cable massappr.(kg/km) Radius of bend(mm) Effect.resist.ofconductors( Short circuit current-equiv.(kA) Time heating constant(sec) Current carryingcap.in air (A) Inductivity(mH/km) Min.tensilestrength( Content Cu(kg/km) 2 ) ⌠/km) N ) 2x6RE15 4121803,0800,6808951730,290118 3x1,5RE13 24415612,1000,1703619270,34044 ĹĽ3x2,5RE14 2941687,4100,2806525360,31074 3x4RE16 3931924,6100,4508934460,310118 3x6RE17 4812043,0800,68012643580,290176 3x10RE18 6452161,8301,15018659780,270294 3x16RE20 8722401,1501,840272781010,260470 3x25+16RM+RE25 1 5133000,7202,8703661051320,270892 ĹĽ3x35+16RMV+RE27 1 8043240,5244,0204751291590,2601 186 3x50+25SM+RM31 2 3493720,3875,7006551571880,2601 715 3x70+35SM35 3 1174200,2688,0007991992320,2502 401 ĹĽ3x95+50SM39 4 1674680,19310,90010832462800,2503 283 ĹĽ3x120+70SM44 5 1905280,15313,80011452853180,2504 018 3x150+70SM47 6 1615640,12517,20013673263590,2405 096 3x185+95SM53 7 6736360,09921,20015803744060,2406 370 3x240+120SM59 9 8507080,07527,60018794454730,2408 232 4x1,5RE14 27816812,1000,1703619270,36059 4x2,5RE15 3401807,4100,2806525360,33098 4x4RE17 4602044,6100,4508934460,330157 4x6RE18 5702163,0800,68012743580,310235 4x10RE20 7752401,8301,15018659780,300392 ĹĽ4x16RE22 1 0722641,1501,840272781070,280627 ĹĽ4x25RM27 1 6323240,7202,8703661051320,270980 4x35SM27 1 9593240,5244,0204751291590,2701 372 4x50SM32 2 5953840,3875,7406551571880,2701 960 ĹĽ4x70SM36 3 4884320,2688,0407991992320,2602 744 4x95SM41 4 6374920,19310,9009632462800,2603 724 4x120SM43 5 6895160,15313,8001,1452853180,2504 704 4x150SM49 6 9735880,12517,2001,3673263590,2505 880 4x185SM54 8 6636480,09921,2001,5803744060,2507 252 4x240SM60 11 1407200,07527,6001,8794454730,2509 408 5x1,5RE15 31718012,1000,1703619270,40074 ĹĽ5x2,5RE16 3911927,4100,2806525360,380123 5x4RE18 5372164,6100,4508934460,370196 5x6RE19 6722283,0800,6804343580,360294 ĹĽ5x10RE21 9212521,8301,15018659780,340490 5x16RE24 1 2942881,1501,840272781010,320784 5x25RM29 2 0043480,7202,8703661051320,3201 225 ĹĽ5x35RMV30 2 5753600,5244,0204751291590,3101 715 5x50SM36 3 1934320,3875,7406551571880,3102 450 5x70SM40 4 3194800,2688,0407991992320,3003 430 5x95SM46 5 7835520,19310,9009632462800,3004 655 5x120SM50 7 0956000,15313,8001,1452853180,2905 880 Äiselné údaje jsou bez záruky a podléhaji zmÄnám bez pĹedchozího oznámení./ Numerical data are not guaranteed, and they are subject to changes without notification.Vliv na ivotní prostĹedí:Výrobek neovlivĹuje negativnÄ ivotní prostĹedí./ Influence on the environment:The product does not have any negative influance on the environment.U 1-ilových kabelĹŻ platí hodnota zatíitelnosti pro stejnosmÄrnou soustavu se vzdáleným zpÄtným vodiÄem.PĹi pouití v 3.fázové soustavÄ je tĹeba provéstpĹepoÄet podle uspoĹádání jednotlivých fázových kabelĹŻ. /Values indicating current carrying capacity for single-phase conductor are valid in DC system with remote conductor.When using this cable in 3-phase circuit a recalculation according to configuration of phase conductors have to be executed.Power cables - 17613 51 |