|
catalogue search
|
You may also be interested in
Wiring harness, Power distribution cable, Medium voltage cable, Power distribution, High-voltage cable
Text version of the page
1-CYKYDYCeloplastové kabely / PVC Insulated CablesKabely s Cu jádrem a Fe pancíĹemKonstrukce: / Cables with Cu-Conductor and Fe-Armouring Pouití: 1.MÄdÄné jádro4.PVC pláĹĽ vnitĹníĹĽ2.PVC izolace5.PancíĹ z ocelových ĹĽ3.VýplĹový obalpozink.kulatých drátĹŻ6.PVC pláĹĽ1.Copper conductor4.PVC inner sheathĹĽ2.PVC insulation5.Armouring of galvanized ĹĽ3.Beddingsteel wires6.PVC sheath Construction: 6 5 4 3 2 1 Technická specifikaceTP-KK-133/01 Min.teplota pokládky a manipulace s kabelem ( C) -5 / Standard / Min.temperature for laying and manipulation with cables Jmenovité napÄtí U /U (kV)0,6/1 Rozsah teplot pĹi provozu ( C) -35 a +70 / Rated voltage / Temperature range for handling / from -35 to +70 Zkuební napÄtí (kV) 4 Barva izolaceHD 308.S2 / Test voltage / Color of insulation Maximální provoz.teplota pĹi zkratu ( C) 160 Barva plátÄÄerná / Maximal short-circuit temperature / Color of sheath/ black Provozní teplota jádra ( C) 70 Baleníkabelové bubny / Operating cond.temperature / Packaging/ cable drums Pro pevné uloení ve vnitĹních a venkovních prostorách, v zemi, v betonu, zejména pĹi zvýeném nebezpeÄí mechanického pokození.Kabelyjsou odolné proti UV záĹení a proti íĹení plamene dle ÄSN EN 50 265-2-1.PrĹŻĹez ochranného vodiÄe dle ÄSN 33 2000-4-41. For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage.The cables are resistant to UV radiationand to flame propagation according to CSN EN 50 265-2-1. Application: PoÄet a prĹŻĹez il(mm Tvarjádra PrĹŻmÄr inf.(mm) Hmotnost inf.(kg/km) PolomÄr ohybu(mm) Äinný odpor ( Ekvivalentnízkrat.proud(kA) Äasová otep-lovací konst.(sec) Zatiitelnostna vzduchu(A) Zatíitelnostv zemi(A) Kapacita( IndukÄnost (mH/km) Obsah Cu(kg/km) 2 ) ⌠/km) ľ F/km) No.of cores(mm Shape of the conductor Diameterappr.(mm) Cable massappr.(kg/km) Radius of bend(mm) Effect.resist.of conductors( Short circuit current-equiv.(kA) Time heating constant(sec) Current carryingcap.in air (A) Current carryingcap.in ground(A) Capacity( Inductivity(mH/km) Content Cu(kg/km) 2 ) ⌠/km) ľ H/km) 3x25RM322 2983840,7272,880366105132-0,2507353x35RMV332 6513960,5244,030475129159-0,2401 0293x35+25RMV+RM343 6924000,5244,030475129159-0,2601 2473x50SM352 9124200,3875,750655157188-0,2401 470ĹĽ3x50+25SM+RM353 3534220,3875,750655157188-0,2501 7153x50+35SM+RMV35,23 4274220,3875,750655157188-0,2601 8133x70SM374 6994440,2688,050799199232-0,2302 0583x70+35SM38,14 1884600,2688,050799199232-0,2402 4013x70+50SM+RMV404 3174850,2688,050799199232-0,2502 5483x95SM44 4 7215300,19310,900963246280-0,2302 7933x95+50SM46 5 7925550,19310,900963246280-0,2503 2833x120SM47 6 0185700,15313,8001 145285318-0,2303 5293x120+70SM486 9095800,15313,8001 145285318-0,2403 871ĹĽ3x150SM507 1416150,12517,3001 367326359-0,2304 4103x150+70SM518 0716400,12517,3001 367326359-0,2505 096 39 |