| | Model | NGM1 | NGM2 | NGM4 | NGM10 | NGM40 | NGM50 | |
| | Meter type | Pulse | Pulse (refer to meter numbering system for LCD or mechanical options) | |
| | Meter body material Wetted components: Rotor material Shafts O-rings | PPS (Polyphenylene Sulfide) or 316 Stainless steel PPS or 316 SS PPS or 316 SS 316 Stainless steel (Hastelloy optional) Viton* (standard model) | PPS or 316 SS | PPS, Aluminum or 316 Stainless steel PPS or 316 SS PPS or 316 SS PPS 316 Stainless steel NBR Nitrile (For options refer to numbering system) | |
| | Flow rate ranges (Gallons/Liters) Above 5 CPS | 0.26 to 26.4 GPH 1 to 100 LPH | 0.66 to 132 GPH 15 to 500 LPH | 0.26 to 7.9 GPM 1 to 30 LPM | 1.6 to 32 GPM 6 to 120 LPM | 2.6 to 66 GPM 10 to 250 LPM | 4 to 93 GPM 15 to 350 LPM | |
| | Below 5 CPS | 0.53 to 26.4 GPH 2 to 100 LPH | 1.85 to 132 GPH 25 to 500 LPH | 0.8 to 6.6 GPM 3 to 25 LPM | 2.6 to 26GPM 10 to 100 LPM | 4 to 62 GPM 15 to 235 LPM | 8 to 80 GPM 30 to 303 LPM | |
| | Accuracy - reading (of reading) | ± 1% | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
| | Maximum viscosity (of standard model) | 1000 Centipoise | 1000 Centipoise, std. model (above 1000, see page 4 for flow rates) | |
| | Maximum operating pressure | 75/150 PSI (PPS/SS) • 500/1000 kPa • 5/10 BAR | 800 PSI • 5500 kPa • 55 BAR or flange rule where fitted | |
| | Pulser type | Hall effect sensor or reed switch | Reed switch (For options refer to numbering system) | |
| | Pulses per units (Gallons/Liters) | 3785 gal. 1000 liters | 1514 gal. 400 liters | 424 or 828 gal. 112 or 224 liters | 136.3 or 272.6 gal. 36 or 72 liters | 54.9 or 109.7 gal. 14.5 or 29 liters | 25.4 or 50.8 gal. 6.7 or 13.4 liters | |
| | Max.operating temperature | 176o F / 80o C (For higher temperature rotors refer to page 4) | |
| | Recommended mesh strainer size | 200 mesh | 60 mesh | |
| | Will handle particle size | 0.005" 0.0127mm | 0.005" 0.0127mm | 0.011< 0.28mm | 0.011< 0.28mm | 0.015 < 0.38mm | 0.018 < 0.46mm | |
| | | | | | | | | |