Oscillating Piston Principle of OperationLiquid enters a precision-machined chamber containing an oscillating (rotating) piston.The positionof the piston divides the chamber into compartments containing an exact volume.Liquid pressure drives the piston to oscillate and rotate its center hub.The movements of the hub are sensed through the meter cover by a follower magnet.Each revolution of the piston hub is equivalent to a fixed volume of fluid, which is indicated as flow by a register/totalizer.Close clearances between the piston and the chamber ensure minimum liquid slip for highly accurate and repeatable measurement of each volume cycle. High AccuracyFigure 1. Oscillating Pistonwith R-22 registerAccessoriesFigure 2. Oscillating Pistonwith R-15 register- Two-stage shut-off valves - Rate of flow indicators - Totalizers - Batch controllersBenefits+0.5% of rateExceptional ValueEliminates upstream and downstream straight run piping requirementsPower not required for mechanical versionReliable Design Standard 316 SS/ETFE allows user flexibility with different fluids and Construction1(864) 574-3327 (800) 778-9251 Fax:(864) 574.8063 www.venturemeas.com/niagara niagarasales@venturemeas.com |
|