| | | | | | | | | | | | | | | | | | | | | | Model 3030F Batch Controller Indicator/Totalizer | | | | | | | | | | Description Indicates rate, total, and provides single or dual stage batch control. Two parameters can be simultaneously displayed. The unit contains two process inputs, five control inputs, and four control outputs. A user-friendly menu system provides scrolling help messages to make programming simple when changes are required. The unit contains a set point lock out system to prevent unauthorized changes from the front panel and a 10-year memory backs up all program settings and flow parameters in case of a power failure. The unit can be factory programmed for your application. Use with Aaliant and Niagara's Target, Nutating Disc, Oscillating Piston, Turbine flowmeters. | | | | | | | | | | Technical Information Functional Specifications | | | | | | | | | | | | | | | | | Power Supply | 18 to 27 VDC/6 Watts max, 0.4 Amps max and 1 phase 50/60 Hz 115/230 VAC +10% - 15%/0.2/0.1 Amps | | | | Accessory Power | Only if unit is AC powered/24 VDC + 5%/100 mA max | | | | Temperature | Operating: 32° F to 131° F (0° C to 55° C) Storage: - 40° F to 158° F (- 40° C to 70° C) | | | | Display Outputs | Two parameters simultaneously | | | | Display diqits | 6 for Rate, 10 for Total, 6 for Batch, 3 for alphabetical characters | | | | Flow Inputs | | | | Type | Current sinking (contact closure or npn transistor to ground) | | | | Impedance | 5.8 Kfi pull-up resistor to + 5 VDC | | | | Logical Voltages | 0.0 to 2.2 VDC low, 2.8 to 24 VDC high | | | | Response | 0 to 40 Hz max with 10 msec minimum pulse width 0 to 400 Hz max with 1.5 msec minimum pulse width 0 to 7.5 KHz max with 50 usec minimum pulse width | | | | Input A | Flow | | | | Input B | Flow input inhibit (flow input ignored when pulled low) | | | | Start | Batch Controller: disabled, only start, or reset batch count and start Rate Meter: No function Totalizer: none, reset totalizer count, unlatch totalizer set point output, or reset totalizer count and unlatch totalizer set point output | | | | Reset | Batch Controller: none, reset batch count, unlatch batch overrun set point output, or reset batch count and unlatch batch overrun set point output Rate Meter: none, or unlatch rate hi/lo set point outputs Totalizer: none, reset totalizer count, unlatch totalizer set point output, or reset totalizer count and unlatch totalizer set point output | | | | Stop | Batch Controller: only stop, or stop and unlatch batch overrun set point output Rate Meter: none, or unlatch rate hi/lo set point outputs Totalizer: no function | | | | Control Inputs | | | | Qty | 5 | | | | Type | Current sinking (contact closure or npn transistor to ground) | | | | Impedance | 5.8 Kfi pull-up resistor to + 5 VDC | | | | Logical Voltages | 0.0 to 1.0 VDC low, 3.5 to 24 VDC high | | | | Response | 30 msec input | | | | Control Input 1 | Use: Batch start | | | | Control Input 2 | Use: Reset batch count and unlatch batch overrun set point output, unlatch rate hi/lo set point outputs, and unlatch totalizer set point output | | | | Control Input 3 | Use: Batch stop | | | | Control Input 4 | Use: Batch jog | | | | Control Input 5 | Use: Unlatch batch overrun set point output, unlatch rate hi/lo set point outputs, and unlatch totalizer set point output | | | | | | | | | | | | | Figure 1. Model 3030FW Batch Controller Indicator/Totalizer | | | | | | | | | | | | | | 1 | | | | | | | | | | | | | | | | | | | | | |
|