You may also be interested in
Surge suppressor, Surge arrester, Gas-discharge surge arrester, Filter, Feedthrough filter
Text version of the page
Product Specification PTC SAM SAF xxSGas Discharge Tube Lightning Protector SMA connectorsFeatures: Multiple Strike Capability 20 kA Surge Protection Lifetime gas tube Rugged and water resistant DC pass Bi-directional ProtectionRF SpecificationsNominal Impedance: 50 Frequency Insertion (GHz) VSWR Loss (dB) dc – 2.5 1.2 Max 0.15 Max Through Current: 65V/5 A Max RF Power: See Protection Voltage tableTransient Specifications(1.2X50 s Voltage / 8X20 s Current waveform) Gas Discharge Tube 90 to 470 V Maximum Transient: 20 kA (surge limited by SMA connector size) Multiple Strike: 10kA 10 times Let-through: See Protection Voltage table Typical VSWR and Insertion Loss©NexTek, Inc. This specification is for reference only, and is subject to change without notice Page 1 of 2 439 Littleton Road (978) 486-0582 Westford, MA 01886 www.nexteklightning.com |
|