Controllers and PLC based systems Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak, the signal from the detector has to be processed into an alarm event. There are various options to handle this part of the safety process adequately. It is a question of site policy, design and space, sound recommendation and the customer’s choice. Bionics Instrument • Rack, panel and wall mount alarm units. • Local and centralized alarm systems. • RS-485 output signals for connection to data acquisition and monitoring systems. • Systems which provide maximum flexibility towards th

Open the catalog to page 1
Controllers and PLC based systems - 2

PLC Alarm System PLC-system As technology moves on, more sophisticated alarm systems are widely used. When implementing systems with more than twenty five detectors, the use of a PLC-system is worth to consider. Such a compact, software-driven system is simple to expand and allows for quick modifications. User specific functions can easily be programmed. For example functions, which enable the communication with other systems in the facility. Reliable Bionics Instrument uses PLC-systems made by Siemens, which feature the fail-safe redundant configuration with two parallel operating...

Open the catalog to page 2
Controllers and PLC based systems - 3

Software for PLC Alarm System SIMS-NX Software Sensor Information Management System A PLC-system has lots of advantages. But on its own, it fails to have the possibility of visualisation; it is a 'blind box'. SIMS-NX is designed to monitor and display the signals of a large variety of sensors on pc screens. That makes SIMS-NX the natural partner fora PLC-configuration.The combination is hard to beat when it comes to flexibility, reliability and functionality. PACT Software PACT is used to program the alarm handling procedures of the PLC-system. An user friendly, well structured, interface...

Open the catalog to page 3
Controllers and PLC based systems - 4

Single channel controller cards and housings RX-1G Single channel alarm card with a direct indication of the gas concentration. With a 4-20mA input signal and an RS-485 output signal (SIMS). Each card has integrated relay contacts for Alarm1, Alarm2 and Error. When placed in one of the belonging housing the cards can be used to create both small and large alarm systems. Available Housings mmmmmiiiiimtritrim nm nm nn] tnn mo mo tnn mo tnn rrm n n 10FRO, 19'' rack housing. Also available as 12FRO with 12 positions for a RX-1G card.

Open the catalog to page 4
Controllers and PLC based systems - 5

Alarm controller A controller is used to convert a signal from a gas detector into an actual alarm. It displays the level of the gas monitored and indicates a possible alarm status with red LEDs. In case of an alarm, a buzzer alerts the operator. Free programmable potential free dry output contacts are available for each alarm level. Centralised alarm handling With larger installations the alarm handling often takes place from a central location. Traditionally this is realised with individual RX-1G alarm indicator controllers located at cabinet housings using 19" racks. More flexibility is...

Open the catalog to page 5
Controllers and PLC based systems - 6

* Dimensions shown without cooling kit All rights reserved, © 2008 Bionics Instrument, Eur83-ALA-v16 Bionics Instrument Co.,Ltd. 6-1254-2 Shimizu, Higashiyamato, Tokyo, 207 Japan Tel. : +81-425-61-4856 Bionics Instrument Europe B.V. Maxwellstraat 7, 1704 SG Heerhugowaard, The Netherlands Tel. : +31-72-5765630 E-mail : info@bionics.net PureAire Monitoring Systems, Inc. 55,7 Capita' D^6, Lake Zurich, Illinois 60047, USA Tel. : +1-847-726-6000

Open the catalog to page 6

All New Cosmos catalogs and technical brochures

  1. KS-7R

    2 Pages

  2. SH-4004-WAD

    1 Pages

  3. SH-4002-WAD

    1 Pages

  4. SH-4001-WAD

    1 Pages

  5. PS-7

    1 Pages

  6. KD-12A

    4 Pages

  7. SDM-72/73

    1 Pages

  8. New Energy

    2 Pages