You may also be interested in
Sensor, Catalytic sensor, Toxic gas sensor, Gas sensor, Hydrogen sulfide sensor
Text version of the page
NEMOTOTECH S.r.l. – 20010 Cornaredo (MI) ITALY Via Legnano, 2 – Tel.+39.02.93544190 – Fax +39 .02. 93540347
C.F. e P. IVA (VAT) 03231490966 – CAPITAL . 36.000 EU – Website: www.nemototech.it – E-mail: info@nemototech.it
TECHNICAL INFORMATION SHEET:
NEMOTO NP-30 Pellistor Gas Sensor
General Description
The Nemoto NP-30 is a catalytic (pellistor) type
flammable gas sensor supplied as a matched pair of
elements mounted on TO4 size headers and
protected by a metal can.
The sensor detects and measures the presence of
flammable gases and vapours in air, in the range 0-
100% of the Lower Explosive Limit (LEL) of the gas
or vapour being measured.
Designed as a sensing platform for use in fixed
flammable gas detection systems, the NP-30
exhibits excellent long term zero and sensitivity
stability and a high level of resistance to catalytic
poisons. The device is compatible with a wide range
of commercially available Gas Detection Systems
and remote flammable gas detection heads.
The highly automated manufacturing procedure
employed by Nemoto results in a repeatable reliable
sensor which, unlike similar devices, requires no
trimming resistor to enable the detector to be
matched with a compensator.
Specifications
Recommended Voltage: 2.0V +/- 0.1V
Current Drawn: 300 +/- 20mA
Zero Offset: 0mV +/- 25mV
Minimum Sensitivity: 20mV/% CH4/Air
Range: 0-100% LEL
Accuracy: +/- 1%LEL(CH4)
Maximum Long Term Drift:
Span: < +/- 1% Signal/Month
Zero: <+/- ˝ mV/Month
Response Time: T50: 3 sec T90: 8 sec
Recommended Circuit:
Note: The value R1 is arbitrary, since the function of R1 is
to balance the bridge. 1K is suggested.
Temperature Range: -20°C to +70°C
Temperature Drift: (-20°C to +70°C)
Zero: < +/- 2%LEL
Humidity: 0-100%RH, non-condensing
Humidity Response: +/- 1%LEL
Linearity: Effectively Linear to 60%LEL
Test data on drift, poisoning, temperature
performance, linearity are available on the
Characterisation Document.
Nemoto has a policy of continuous development and
improvement of its products. As such the specification for the
device outlined in the data sheet may be changed without notice
ds-np30.doc, issue 6, May 2008
|
|