SCC Configuration Guide SCC – Portable, Low-Cost Signal Conditioning • Ideal for portable measurement systems • Wide variety of direct signal and sensor connectivity options • Wide range of analog and digital conditioning options • Measurement type selectable on a per-channel basis • Front-end signal conditioning for M Series, E Series, and some B Series multifunction DAQ devices Configure Your SCC System in Six Steps Step 1 – Select Your SCC Modules (Table 1) Analog input, analog output, and digital I/O modules have dedicated slots. You can select up to eight noncascaded modules for analog input and eight modules for digital I/O. You can install feedthrough modules in any slot, but they are especially useful for accessing counter/timers on your M Series, E Series, or B Series multifunction DAQ device. Step 2 – Choose an SCC Carrier (Table 2) SCC carriers are available either with a hinged lid or with configurable connectors using panelettes. Hinged lids provide quick access to the modules. Configurable connectors provide custom signalinterface options. Step 3 – Select Your Panelettes (Table 3) If you have chosen an SCC carrier with configurable connectors, you can also select connector and interface panelettes. Different carriers offer different numbers of panelette slots. Also, some panelettes occupy more than one slot. Step 4 – Determine Your Power Option (Table 4) You can power an SCC system using a +5 VDC, 120/240 VAC, or 7 to 42 VDC external power source. To indicate the power option for your SCC system, select 01, 02, or 03 as the last two digits of the part number of the SC-2345 or SC-2350 carrier. Please note that if you choose power option 01, it is possible to power your SCC system using the internal power source of your DAQ device. For DAQCard and DAQPad devices, the total power required by your SCC modules must be less than 800 mW (490 mW of analog power). For PCI or PXI and M Series or E Series multifunction DAQ devices, the total power required by your SCC modules must be less than 4.55 W (1.74 W for analog modules). Additional power modules are sold separately. To determine the power requirements of the modules in your SCC DAQ system, use the online SCC Advisor at ni.com/advisors. Step 5 – Select Your DAQ Device and Cable (Table 5) Select the DAQ device to control your system. Step 6 – Select Your Accessories Choose from rack/panel-mount kits and stacking kits. You can also select additional power kits separately if your application requires multiple power configurations.
Open the catalog to page 1SCC Configuration Guide SCC Modules Millivolts/Volts Current (0 to 20 mA) Frequency-to-Voltage Thermocouples RTD Strain Gages Force, Load, Torque, Pressure Accelerometer TTL/CMOS Signal Types – – – – – – – – Description Isolation amplifier 2 ISO 2 DI 2 DI 2 DI 2 DI 2 DI 2 RSE 1 DI 1 DI 2 DI 2 DI 2 DI 2 DI 2 DI 2 DI 2 DI 1 DI 2 DI 1 ISO 1 ISO 1 ISO 1 ISO 1 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –...
Open the catalog to page 2SCC carrier with a hinged lid SCC carrier with configurable connectors (side 68-pin interface) SCC carrier with configurable connectors (rear 68-pin interface) Number of Panel ette Slots Power Options Power Type Power Option AC transformer included. However, you must purchase a sepamte power cord to match your country':: power requirements. ^External power supply nol included._ Table 5. National Instruments DAQ Devices i 1 SCC Advhor - National Instruments - Microsoft Internet Explorer Fte E* »ew (jo Bookmarks Tools Help Select Your SCC Modules Expand a field snc seled modiJe(s) that meet your...
Open the catalog to page 3Portable, Modular Signal Conditioning Modules Nl SCC-LP Series Lowpass Filters Part Number The National Instruments SCC-LP Series consists of dual-channel lowpass filter modules that accept two ±10 V signals. Each channel has a 4th-order Butterworth filter. The cutoff frequency is specific to the module and applies to both channels of the module. SCC-LP Series Amplifier Characteristics Filter Characteristics Passband Ripple System Noise Wide band noise Narrow band noise Power Requirements BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Open the catalog to page 12NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule...
Open the catalog to page 1710 Pages
9 Pages
12 Pages
7 Pages
9 Pages
13 Pages
14 Pages
5 Pages
13 Pages
5 Pages
5 Pages
7 Pages
4 Pages
9 Pages
8 Pages
15 Pages
8 Pages
5 Pages
5 Pages
4 Pages
1 Page
9 Pages
2 Pages
18 Pages
14 Pages
6 Pages
17 Pages
5 Pages
5 Pages
9 Pages
17 Pages
13 Pages
3 Pages
3 Pages
5 Pages
5 Pages
3 Pages
9 Pages
7 Pages
2 Pages
14 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
5 Pages
5 Pages
4 Pages
5 Pages
1 Page
4 Pages
10 Pages
3 Pages
1 Page
3 Pages
1 Page