You may also be interested in
Magnetic field measuring device, Analyzer, Magnetometer, Signal analyzer, Detector
Text version of the page
Calculation Electric and Magnetic FieldPower Transmission Lines - according to VDE 0848Technical Data: Magnetic Field Calculation 32-bit runtime version 3D-calculation of Biot-Savart-Equation calculation of RMS value, peak and components batch job available time dependent field components integrated data compression automatic calculation of ground wire currents user interface configuration height at midspan by classification of segments user defined colors frequency range 0 to 500 Hz support of 16, 256 and true color graphics Geometric Objects Electric Field Calculation max. 50000 conductors up to 32000 charge segments max. 100 transmission or railway lines ground influence max. 1000 towers Gauss-Jordan or sparse-matrix inversion max. 100 isolated towers calculation of tower and building influence max. 1000 buildings max. 1000 blocks Power Transmission Lines Support tower library Calculation Modes user defined towers max. 32000 x 32000 points automatic segmentation of towers calculation along a straight 3D-line replacement of towers in transmission lines calculation on an area in space change tower types of transmission lines profile series in z-direction system or phase voltage dynamic interpolation of data points Al/St/Cu wire input check on Kirchhoff-law phase optimization temperature adjustment Object Manipulation Data Interface good survey and easy input of geometry data shift, rotation, insertion etc. of geometry data ground profiles loadable reusable blocks of conductors import of experimental data polylines, coils etc. of conductors map-import as DXF, PCX and JPEG loading of towers and railway profiles from library DXF-export of Isolines, hatch pattern, solids ASCII-export (EXCELTM -readable format) TM Data Presentation export of 4D - colored areas (Stanfort Graphics ) export/import of dBase TM and Paradox TM files X, Y, Z-axis plots creation of database reports and protocols 2D-Isoline plots bitmap, WMF, JPG, html and CD export 3D-surface plots representation of conductors Integrated Tools statistics, histograms average value, L05, L50, L95-value Editor, Calculator zoom function Paint-Tool proportional view DXF-object filter Performance Hardware Requirements max. 1.000.000 points/sec (Pentium TM , 1 GHz) 64 MB RAM, HD 600 MB free TM runtime version for external calculation WIN 95/98 / WIN NT / Win 2000 / Win XP USA : Long Island, NY Germany : Pfullingen Fon +1-631-231-1700 Fax -1711 Fon +49-7121-9732-777 Fax -790 NardaSTS@L-3COM.com Subject to change without notice Support@narda-sts.de www.narda-sts.com www.narda-sts.de NSTS 0705-E0216A-0.0 2 / 2 Narda Safety Test Solutions and Partner FGEU |
|