6.1.3.3. ST_S C AN (S canning start signal)
Scanning is executed when DSEL0-3 specifies movement data number, DIR selects movement direction and ST_SCAN goes ON while RDY signal is ON. Stop is executed when deceleration stop signal (SSTOP) goes ON.
Example movement of scanning
O
ST_SCAN signal
_O_
SSTOP signal
Deceleration stop
Start
6.1.3.4. ST _JOG (Jogging movement start signal)
Jogging is executed when DSELO-3 specifies movement data number, DIR selects movement direction and ST_JOG goes ON while RDY signal is ON. Movement continues while ST_JOG is ON.
Example movement of jogging
ON
ON
ST_SCAN signal
4-
Start
Stop
Start Stop
6.1.4. Movement direction selection signal (DIR)
This is movement direction selection signal for scanning and jogging.
Please refer DIR(direction signal) for the movement direction to be selected by DIR.