General Specifications
Standard Probe Specifications
Temperature Range: -100°F to 300°F (-70°C to 150°C).
Operating Pressure Range: vacuum of 29 in. Hg to 500 psig. (MTII does not guarantee leak-proof operation)
Tip Length: 3 in. (76.2 mm).
Cable Length: 54 in. (1,372 mm) standard.
Power Requirements
100 to 240 Vac, 50/60 Hz.
Maximum Power Dissipation: 35 W.
Industrial fuse: 1.25 A, time delay, 250 V, 5 x 20 mm.
Dimensions Weight
5.6 in. (14.2 cm) H. 10 lb. (4.5 kg).
14.1 in. (35.8 cm) W. 10.5 in. (26.7 cm) D.
Environmental Requirements Instrument Operating Temperature:
50°F to 110°F (10°C to 43°C) non-condensing. Instrument Storage Range:
0°F to 150°F (-18°C to 65°C) non-condensing.
Display
Meter: graphic LCD, white on blue background, 100 Hz response,
updates 3 times per second. Bar Graph: 20-element green LED (0.5 Volt step size), 10 Hz response.
Displacement Measurements
Output Signal: 0 to 10 Vdc, 51 Q output impedance.
Stability at 12 hrs., ± 2°F (± 1°C): drift less than 1.0% of full scale.
Stability at 60°F to 95°F (16°C to 35°C): drift less than 2.0% of full scale.
Output Signal: 0 to 10 Vdc full-scale range, 51 Q output impedance. Accuracy: within 1.0% for peak-to-peak readings from 15 Hz to
150 kHz (probe-dependent). System Noise: dependent upon probe type and surface reflectivity.
High/Low Pass Filters
High Pass Filter: DC, 20 Hz, 200 Hz front-panel selectable 4-pole
Butterworth response (-3 dB at value selected). Low Pass Filter: 100 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz and
wide band, 1-pole response (-3 dB at 1.2 X value selected).
RS-232 Data Output
Displacement Data Accuracy: within 1% for signals from dc to 100 Hz. Vibration Data Accuracy: within 1% for peak-to-peak displacements from 15 Hz to the maximum frequency response of probe module in use.
0.50 in.
Options
• Bent Probe Tips: consult factory for minimum bend radius.
• High-Pressure/High-Vacuum Probes.
• Wide Temperature Range Probes: from -310°F to 1,380°F (-190°C to 750°C).
Accessories
Optical Probe Extenders: Precision lens systems that permit operation of standard fiber-optic probes at a greater standoff distance with no loss of probe sensitivity or frequency response.
FS-3 Probe Mounting Fixture: Used to position the probe over the target being measured. Consists of a magnetic base, two extension arms, probe mounting clamp for diameters up to 0.125 in. (3.2 mm) and micrometer for fine position adjustment.
Mil Instruments has been at the forefront of non-contact measurement technology for nearly 50 years. Our application engineers will be happy to work with you to determine the best solution for your measurement needs. _
For information on other non-contact products or custom solutions from
MTI Instruments, contact us at 1-800-342-2203 or + 1-518-218-2550.
MTI Instruments, Inc.
325 Washington Avenue Extension Albany, NY 12205 ph: +1-518-218-2550
or usa toll free: 1-800-342-2203
fx: +1-518-218-2506
email: sales@mtiinstruments.com
www.mtiinstruments.com
mti instruments
A subsidiary of Mechanical Technology, Inc. (NASDAQ:MKTY)
+
+
3500/10.06 blc mt135045 10.06
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6