Catalog excerpts
Maximum pressure 110 bar Flow rates to 80 l/min Te c h n i c a l d a t a Filter housing (Materials) • Head: Anodized aluminium • Housing: Anodized aluminium • Bypass valve: Steel Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0,86 kg/dm3 to ISO 3968. Pressure • Working pressure: 110 bar (11 MPa) • Test pressure: 170 bar (17 MPa) • Burst pressure: 330 bar (33 MPa) • Pulse pressure fatigue test: 1.000.000 cycles with pressure from 0 to 110 bar (11 MPa) Δp varies proportionally with density. With bypass • From -25°C to +110°C Bypass valve • Opening pressure 6 bar ±10% • Other opening pressures on request. Δp Elements type • Microfibre filter elements series N: 20 bar • Wire mesh filter elements series N: 20 bar • Fluid flow through the filter element from OUT to IN. Flow rate l/min Valves Bypass valve pressure drop FMP 039 FILTERS ARE PROVIDED FOR VERTICAL MOUNTING Weights (kg) Length • FMP 039 Flow rate l/min Connections • FMP 039: In-line Inlet/Outlet PRESSURE FILTER Recommended maximum flow rate - Pressure drop of filter assembly equal to Δp 1,5 bar. - Oil kinematic viscosity 30 mm2/s (cSt). - Density 0,86 kg/dm3. - Connections of filter under test G 1/2”.
Open the catalog to page 1Execution 1: Without indicator connection Execution 6: Double indicator connection (A - B) A: Closure cap with standard T2 steel. The position of the cap is reversible. B: Standard closure cap with plastic thread protection. If necessary, the second plug T2, see page 15 ordering information. Indicator port T2 Plug - A/F 30 Execution “6” Special connections on request PRESSURE FILTER Thread connections
Open the catalog to page 2Item Description Filter assembly Filter element O-Ring for filter element Anti-extrusion ring O-Ring indicator PRESSURE FILTER Indicator connection plug
Open the catalog to page 3Filter assembly Filter element Filter element Without indicator port With 2 indicators port* Inorganic microfibre 3 μm Inorganic microfibre 6 μm Without bypass With bypass Nominal Filtration 8 - Max filter element differential pressure Absolute filtration Inorganic Microfibre MP Filtri standard On request Indicator plug: Phosphated Steel plug T2 has to be ordered separately. Code Seal NBR Seal FPM PRESSURE FILTER For Clogging Indicator: See page 318 MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement...
Open the catalog to page 4All MP Filtri catalogs and technical brochures
-
MULTI-COMPONENTS
31 Pages
-
LMS/LDS Series
17 Pages
-
LMC/LDC Series
17 Pages
-
LMG Series
21 Pages
-
ACCESSORIES
28 Pages
-
BELL HOUSING
72 Pages
-
CLOGGING INDICATORS
24 Pages
-
COUPLINGS
46 Pages
-
CONTAMINATION CONTROL SOLUTIONS
140 Pages
-
Return / Suction Filters
76 Pages
-
SPIN-ON FILTERS
76 Pages
-
Stainless Steel Filters
102 Pages
-
Low & Medium Pressure Filters
168 Pages
-
High Pressure Filters
160 Pages
-
Suction Filters
72 Pages
-
Return Filters
230 Pages
-
FHD - DUPLEX
17 Pages
-
FHF 325 - MANIFOLD
14 Pages
-
FHB - MANIFOLD
16 Pages
-
FHM - MANIFOLD
21 Pages
-
FHP
19 Pages
-
FMP
14 Pages
-
Spin-On Filter
78 Pages
-
Stainless Steel
20 Pages
-
LMP 124
6 Pages
-
MRSX
12 Pages
-
MSH
4 Pages
-
CS - CG - CW - CT
2 Pages
-
MPS
8 Pages
-
LMP 952 - 954
6 Pages
-
LMP 900 - 901
4 Pages
-
LMD 400 - 401 - 431 DUPLEX
8 Pages
-
LMP MULTIPORT
8 Pages
-
FMM 050 - FHA 051
6 Pages
-
Clogging Indicators
26 Pages
-
SF2 250 - 350
4 Pages
-
Suction Strainer
7 Pages
-
FRI
10 Pages
-
MPI
8 Pages
-
MPH
18 Pages
-
MPT
15 Pages
-
filter element CH
1 Pages
-
MST
4 Pages
-
STR
4 Pages
-
RF2
4 Pages
-
MPF
20 Pages
-
LMP 400 - 430
10 Pages
-
LMP 210
5 Pages
-
LMP 110-120-123 MULTIPORT
25 Pages
-
FAS
4 Pages
-
SF2 500
12 Pages
-
SF2 250
8 Pages
-
Structural components
78 Pages
-
SA - SAP
10 Pages
-
STR
4 Pages
-
Condition monitoring products
14 Pages
-
Pressure filters
116 Pages
-
In-line filters
108 Pages
-
Structural components
64 Pages
-
Accessories
68 Pages
-
Catalogue
19 Pages