FHP
19Pages

{{requestButtons}}

Catalog excerpts

FHP - 1

High Pressure filters Maximum pressure up to 420 bar - Flow rate up to 750 l/min High Pressure filters

Open the catalog to page 1
FHP - 2

FILTER SIZING Corrective factor FILTER SIZING Corrective factor The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range 0.4 - 0.6 bar. Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the...

Open the catalog to page 2
FHP - 3

Corrective factor FILTER SIZING Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Suction filters Low & Medium pressure filters Filter element Return / Suction filters Filter element Filter element

Open the catalog to page 3
FHP - 4

Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Stainless steel high pressure filters Filter elemen Filter element Filter element Filter element

Open the catalog to page 4
FHP - 5

Selection Software FILTER SIZING Step Select “FILTERS” Choose filter group (Return Filter, Pressure Filter, etc.) Choose filter type (MPF, MPT, etc.) in function of the max working pressure and the max flow rate Push “PROCEED” Insert all application data to calculate the filter size following the sequence: - working pressure - working flow rate - working pressure drop - working temperature - fluid material and fluid type - filtration media - connection type Push “CALCULATE” to have result; in case of any mistake, the system will advice which parameter is out of range to allow to...

Open the catalog to page 5
FHP - 6

High Pressure filters

Open the catalog to page 6
FHP - 7

High Pressure filters Maximum pressure up to 420 bar - Flow rate up to 750 l/min High Pressure filters

Open the catalog to page 7
FHP - 8

High Pressure filters Maximum pressure up to 420 bar - Flow rate up to 750 l/min Filter housing materials - Head: Phosphatized cast iron - Housing: Phosphatized steel - Bypass valve: AISI 316L (FHP 010 - 011) Brass (FHP 065 - 135 - 320) Steel (FHP 500) - Reverse Flow: Steel (FHP 320 - FHP 500) - Check valve: Steel Pressure - Working pressure: 42 MPa (420 bar) - Test pressure: 63 MPa (630 bar) - Burst pressure: 126 MPa (1260 bar) - Pulse pressure fatigue test: 1 000 000 cycles with pressure from 0 to 42 MPa (420 bar) Bypass valve - Opening pressure 600 kPa (6 bar) - Other opening pressures...

Open the catalog to page 8
FHP - 9

Check Valve Flow rate l/min Pressure drop Flow rate l/min l/min Flow rate FHP 0.00 320 - Pressure drop in Reverse flow valves Flow rate l/min The curves are plotted using mineral oil with ∆p varies proportionally with density. FHP 011 GENERAL INFORMATION

Open the catalog to page 9
FHP - 10

V With reverse flow, without bypass Z With reverse flow, with bypass 6 bar Connection for differential indicator 1 Without 2 With connection Filtration rating (filter media] A03 Inorganic microfiber 3 ^m A06 Inorganic microfiber 6 ^m A10 Inorganic microfiber 10 ^m N 20 bar•_^ P01 MP Filtri standard ACCESSORIES Differential indicators page DEA Electrical differential indicator517 DEM Electrical differential indicator517-518 DLA Electrical / visual differential indicator518-519 DLE Electrical / visual differential indicator 519 page DTA Electronic differential indicator520...

Open the catalog to page 10
FHP - 11

Recommended clearance space for maintenance Recommended clearance space for maintenance Recommended clearance space for maintenance Recommended clearance space for maintenance

Open the catalog to page 11
FHP - 12

COMPLETE FILTER FILTER ELEMENT Element series and size Filtration rating (filter media] A NBR_ N 20 bar P01 MP Filtri standard Differential indicators DEA Electrical differential indicator_ DEM Electrical differential indicator_ DLA Electrical / visual differential indicator DLE Electrical / visual differential indicator ACCESSORIES page 517 DTA Electronic differential indicator 517-518 DVA Visual differential indicator 518-519 DVM Visual differential indicator

Open the catalog to page 12
FHP - 13

Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 13
FHP - 14

Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 14
FHP - 15

^_Length 4 ^^FHP320 ^ H2 [mm] Filter H Execution length [mm] P01 P02 High Pressure filters

Open the catalog to page 15
FHP - 16

Designation & Ordering code COMPLETE FILTER Configuration example: Without bypass With bypass 6 bar With check valve, without bypass With check valve, with bypass 6 bar With reverse flow, without bypass With reverse flow, with bypass 6 bar Filtration rating (filter media) A03 Inorganic microfiber A06 Inorganic microfiber A10 Inorganic microfiber A16 Inorganic microfiber A25 Inorganic microfiber M25 Wire mesh MP Filtri standard • Maintenance from the bottom of the housing Drain plug on length 1 - 2 - 3 • Customized FILTER ELEMENT Configuration example: Element series and size Element length...

Open the catalog to page 16
FHP - 17

TT 455] High Pressure filters

Open the catalog to page 17
FHP - 18

High Pressure filters

Open the catalog to page 18
FHP - 19

High Pressure filters

Open the catalog to page 19

All MP Filtri catalogs and technical brochures

  1. LMS/LDS Series

    17 Pages

  2. LMC/LDC Series

    17 Pages

  3. LMG Series

    21 Pages

  4. ACCESSORIES

    28 Pages

  5. BELL HOUSING

    72 Pages

  6. COUPLINGS

    46 Pages

  7. Return Filters

    230 Pages

  8. FHD - DUPLEX

    17 Pages

  9. FHB - MANIFOLD

    16 Pages

  10. FHM - MANIFOLD

    21 Pages

  11. FMP

    14 Pages

  12. Spin-On Filter

    78 Pages

  13. LMP 124

    6 Pages

  14. MRSX

    12 Pages

  15. MSH

    4 Pages

  16. MPS

    8 Pages

  17. FMP 039

    4 Pages

  18. FRI

    10 Pages

  19. MPI

    8 Pages

  20. MPH

    18 Pages

  21. MPT

    15 Pages

  22. MST

    4 Pages

  23. STR

    4 Pages

  24. RF2

    4 Pages

  25. MPF

    20 Pages

  26. LMP 400 - 430

    10 Pages

  27. LMP 210

    5 Pages

  28. FAS

    4 Pages

  29. SF2 500

    12 Pages

  30. SF2 250

    8 Pages

  31. SA - SAP

    10 Pages

  32. STR

    4 Pages

  33. In-line filters

    108 Pages

  34. Accessories

    68 Pages

  35. Catalogue

    19 Pages