FHM - MANIFOLD
21Pages

{{requestButtons}}

Catalog excerpts

FHM - MANIFOLD - 1

High Pressure filters Maximum pressure up to 320 bar - Flow rate up to 450 l/min High Pressure filters

Open the catalog to page 1
FHM - MANIFOLD - 2

FILTER SIZING Corrective factor FILTER SIZING Corrective factor The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range 0.4 - 0.6 bar. Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the...

Open the catalog to page 2
FHM - MANIFOLD - 3

Corrective factor FILTER SIZING Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Suction filters Low & Medium pressure filters Filter element Return / Suction filters Filter element Filter element

Open the catalog to page 3
FHM - MANIFOLD - 4

Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Stainless steel high pressure filters Filter elemen Filter element Filter element Filter element

Open the catalog to page 4
FHM - MANIFOLD - 5

Selection Software FILTER SIZING Step Select “FILTERS” Choose filter group (Return Filter, Pressure Filter, etc.) Choose filter type (MPF, MPT, etc.) in function of the max working pressure and the max flow rate Push “PROCEED” Insert all application data to calculate the filter size following the sequence: - working pressure - working flow rate - working pressure drop - working temperature - fluid material and fluid type - filtration media - connection type Push “CALCULATE” to have result; in case of any mistake, the system will advice which parameter is out of range to allow to...

Open the catalog to page 5
FHM - MANIFOLD - 6

High Pressure filters

Open the catalog to page 6
FHM - MANIFOLD - 7

High Pressure filters Maximum pressure up to 320 bar - Flow rate up to 450 l/min High Pressure filters

Open the catalog to page 7
FHM - MANIFOLD - 8

Technical data High Pressure filters Maximum pressure up to 320 bar - Flow rate up to 450 l/min Filter housing materials - Head: Phosphatized cast iron - Housing: Phosphatized steel - Bypass valve: Steel - Check valve: Steel Pressure - Working pressure: 32 MPa (320 bar) - Test pressure: 48 MPa (480 bar) - Burst pressure: 96 MPa (960 bar) - Pulse pressure fatigue test: 1 000 000 cycles with pressure from 0 to 32 MPa (320 bar) Bypass valve - Opening pressure 600 kPa (6 bar) - Other opening pressures on request. Seals - Standard NBR series A - Optional FPM series V Ap element type - Microfibre...

Open the catalog to page 8
FHM - MANIFOLD - 9

FHM 050valve pressure drop Bypass - 065 1.50Bypass valve pressure drop Flow rate l/min Flow rate l/min Flow rate l/min Check Valve Check Valve Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min Flow rate l/min 18 Flow rate l/min Flow rate l/m 54 36 Flow rate l/m Flow rate l/min Flow rate l/min Check Valve 12 Check Valve 24 Flow rate l/min 60 80 40 36 24 12 Flow rate l/min Flow l/min 24 24 rate 36 36 12 12 Flow rate l/min Flow rate l/min Bypass valve pressure drop 10 pressure drop 0 Bypass valve 10 Valves 0 Valves valve10 Bypass pressure drop Check Valve Flow Check Valve rate...

Open the catalog to page 9
FHM - MANIFOLD - 10

Designation & Ordering code COMPLETE FILTER Series and size Configuration example: Without bypass G1 Manifold side “A” G2 Manifold side “B” Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic microfiber 10 µm A16 Inorganic microfiber A25 Inorganic microfiber M25 Wire mesh P01 MP Filtri standard Pxx Customized FILTER ELEMENT Element series and size FHM006 Element length Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic microfiber 10 µm A16 Inorganic microfiber A25 Inorganic...

Open the catalog to page 10
FHM - MANIFOLD - 11

Recommended clearance space for maintenance Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 11
FHM - MANIFOLD - 12

Dimensions FHM007 Connection G1 Filter length 2 3 Recommended clearance space for maintenance Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 12
FHM - MANIFOLD - 13

Dimensions FHM010 Connection G1 Filter length 2 3 Recommended clearance space for maintenance Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 13
FHM - MANIFOLD - 14

COMPLETE FILTER T With check valve, without bypass D With check valve, with bypass 6 bar Filtration rating (filter media] A03 Inorganic microfiber 3 ^m A06 Inorganic microfiber 6 ^m A10 Inorganic microfiber 10 ^m N 20 bar•_^ P01 MP Filtri standard FILTER ELEMENT Element series and size Filtration rating (filter media] A03 Inorganic microfiber 3 ^m A06 Inorganic microfiber 6 ^m A10 Inorganic microfiber 10 ^m Differential indicators page DEA Electrical differential indicator517 DEM Electrical differential indicator517-518 DLA Electrical / visual differential indicator518-519 DLE...

Open the catalog to page 14
FHM - MANIFOLD - 15

Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 15
FHM - MANIFOLD - 16

Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 16
FHM - MANIFOLD - 17

High Pressure filters

Open the catalog to page 17
FHM - MANIFOLD - 18

Designation & Ordering code COMPLETE FILTER Configuration example: Without bypass With bypass 6 bar With check valve, without bypass With check valve, with bypass 6 bar Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic microfiber 10 µm A16 Inorganic microfiber A25 Inorganic microfiber M25 Wire mesh P01 MP Filtri standard • P02 Maintenance from the bottom of the housing Pxx Customized FILTER ELEMENT Configuration example: Element series and size Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6...

Open the catalog to page 18
FHM - MANIFOLD - 19

High Pressure filters

Open the catalog to page 19
FHM - MANIFOLD - 20

Length 4 - 5 High Pressure filters

Open the catalog to page 20
FHM - MANIFOLD - 21

High Pressure filters

Open the catalog to page 21

All MP Filtri catalogs and technical brochures

  1. LMS/LDS Series

    17 Pages

  2. LMC/LDC Series

    17 Pages

  3. LMG Series

    21 Pages

  4. ACCESSORIES

    28 Pages

  5. BELL HOUSING

    72 Pages

  6. COUPLINGS

    46 Pages

  7. Return Filters

    230 Pages

  8. FHD - DUPLEX

    17 Pages

  9. FHB - MANIFOLD

    16 Pages

  10. FHP

    19 Pages

  11. FMP

    14 Pages

  12. Spin-On Filter

    78 Pages

  13. LMP 124

    6 Pages

  14. MRSX

    12 Pages

  15. MSH

    4 Pages

  16. MPS

    8 Pages

  17. FMP 039

    4 Pages

  18. FRI

    10 Pages

  19. MPI

    8 Pages

  20. MPH

    18 Pages

  21. MPT

    15 Pages

  22. MST

    4 Pages

  23. STR

    4 Pages

  24. RF2

    4 Pages

  25. MPF

    20 Pages

  26. LMP 400 - 430

    10 Pages

  27. LMP 210

    5 Pages

  28. FAS

    4 Pages

  29. SF2 500

    12 Pages

  30. SF2 250

    8 Pages

  31. SA - SAP

    10 Pages

  32. STR

    4 Pages

  33. In-line filters

    108 Pages

  34. Accessories

    68 Pages

  35. Catalogue

    19 Pages