FHF 325 - MANIFOLD
14Pages

{{requestButtons}}

Catalog excerpts

FHF 325 - MANIFOLD - 1

High Pressure filters Maximum pressure up to 350 bar - Flow rate up to 500 l/min Filter housing according to SAE J2066 for HF4 filter elements Mraimr- 495 High Pressure filters

Open the catalog to page 1
FHF 325 - MANIFOLD - 2

FILTER SIZING Corrective factor FILTER SIZING Corrective factor The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range 0.4 - 0.6 bar. Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the...

Open the catalog to page 2
FHF 325 - MANIFOLD - 3

Corrective factor FILTER SIZING Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Suction filters Low & Medium pressure filters Filter element Return / Suction filters Filter element Filter element

Open the catalog to page 3
FHF 325 - MANIFOLD - 4

Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 30 mm2/s Stainless steel high pressure filters Filter elemen Filter element Filter element Filter element

Open the catalog to page 4
FHF 325 - MANIFOLD - 5

Selection Software FILTER SIZING Step Select “FILTERS” Choose filter group (Return Filter, Pressure Filter, etc.) Choose filter type (MPF, MPT, etc.) in function of the max working pressure and the max flow rate Push “PROCEED” Insert all application data to calculate the filter size following the sequence: - working pressure - working flow rate - working pressure drop - working temperature - fluid material and fluid type - filtration media - connection type Push “CALCULATE” to have result; in case of any mistake, the system will advice which parameter is out of range to allow to...

Open the catalog to page 5
FHF 325 - MANIFOLD - 6

High Pressure filters

Open the catalog to page 6
FHF 325 - MANIFOLD - 7

High Pressure filters Maximum pressure up to 350 bar - Flow rate up to 500 l/min Filter housing according to SAE J2066 for HF4 filter elements Mraimr- 495 High Pressure filters

Open the catalog to page 7
FHF 325 - MANIFOLD - 8

High Pressure filters Maximum pressure up to 350 bar - Flow rate up to 500 l/min Filter housing materials - Head: Phosphatized cast iron - Housing: Phosphatized steel - Cover: Cast iron (chemical heat treatment) - Bypass valve: Brass - Steel Bypass valve - Opening pressure 600 kPa (6 bar) - Other opening pressures on request. Seals - Standard NBR series A - Optional FPM series V Pressure - Working pressure: 35 MPa (350 bar) - Test pressure: 52.5 MPa (525 bar) - Burst pressure: 105 MPa (1050 bar) - Pulse pressure fatigue test: 1 000 000 cycles with pressure from 0 to 35 MPa (350 bar) Ap...

Open the catalog to page 8
FHF 325 - MANIFOLD - 9

GENERAL INFORMATION Filter housing according to SAE J2066 for HF4 filter elements The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density. 1.50 Pressure drop Filter housings ∆p pressure drop Flow rate l/min

Open the catalog to page 9
FHF 325 - MANIFOLD - 10

FHF325 Designation & Ordering code COMPLETE FILTER Configuration example: Without bypass With bypass 6 bar Connection for differential indicator With two connections plugged on both sides Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic microfiber 10 µm A16 Inorganic microfiber A25 Inorganic microfiber M25 Wire mesh P01 MP Filtri standard Pxx Customized FILTER ELEMENT Configuration example: Element series and size Element length Filtration rating (filter media) A03 Inorganic microfiber 3 µm A06 Inorganic microfiber 6 µm A10 Inorganic...

Open the catalog to page 10
FHF 325 - MANIFOLD - 11

FHF325 Dimensions FHF325 Connection A - B - C Filter length 1 2 3 Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 11
FHF 325 - MANIFOLD - 12

FHF325 Dimensions FHF325 Connection G - H Filter length 1 2 3 Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 12
FHF 325 - MANIFOLD - 13

FHF325 FHF325 Connection M - N Filter length 1 2 3 Recommended clearance space for maintenance High Pressure filters

Open the catalog to page 13
FHF 325 - MANIFOLD - 14

Order number for spare parts FHF 325 Connections A - B - C - G - H Filter series Filter Seal Kit code number Indicator connection plug element NBR FPM NBR FPM High Pressure filters

Open the catalog to page 14

All MP Filtri catalogs and technical brochures

  1. LMS/LDS Series

    17 Pages

  2. LMC/LDC Series

    17 Pages

  3. LMG Series

    21 Pages

  4. ACCESSORIES

    28 Pages

  5. BELL HOUSING

    72 Pages

  6. COUPLINGS

    46 Pages

  7. Return Filters

    230 Pages

  8. FHD - DUPLEX

    17 Pages

  9. FHB - MANIFOLD

    16 Pages

  10. FHM - MANIFOLD

    21 Pages

  11. FHP

    19 Pages

  12. FMP

    14 Pages

  13. Spin-On Filter

    78 Pages

  14. LMP 124

    6 Pages

  15. MRSX

    12 Pages

  16. MSH

    4 Pages

  17. MPS

    8 Pages

  18. FMP 039

    4 Pages

  19. FRI

    10 Pages

  20. MPI

    8 Pages

  21. MPH

    18 Pages

  22. MPT

    15 Pages

  23. MST

    4 Pages

  24. STR

    4 Pages

  25. RF2

    4 Pages

  26. MPF

    20 Pages

  27. LMP 400 - 430

    10 Pages

  28. LMP 210

    5 Pages

  29. FAS

    4 Pages

  30. SF2 500

    12 Pages

  31. SF2 250

    8 Pages

  32. SA - SAP

    10 Pages

  33. STR

    4 Pages

  34. In-line filters

    108 Pages

  35. Accessories

    68 Pages

  36. Catalogue

    19 Pages