.2. Schematic for Three Phase Model
Start in Automatic mode -*■ Start in Manual mode Direction Sensor Stop
Position Reached Ready-to-Start Programmable Cam
Position Error
Warning! All outputs connected to inductive loads must be protected from overvoltage by using diodes.
Cycle Time Error (flashing) Braking Voltage Error (always 1)
Reset Error Monitor Braking Voltage VBR -». Operating Mode Measurement Cycle
Wires to motor max. 20m long
lonitor Braking Voltage Vbf
External Brake Relay
Power Supply 3x400V / 50Hz
A
*!! Warning! If using brakes with a supply voltage of 230VAC or 400VAC, a jumper is NOT allowed between MC and S2. In this case S2 must be connected directly to +24V DC. Braking voltage monitoring is then no lon­ger possible. Hence we strongly recommend a 24V DC brake when using this rotary index table.
** If a standard 230/400VAC three phase electric motor is interfaced to our single phase rotary index table controller TIC, a Y-connection must be used. Please refer here to the description on the motor terminal block.
A