Catalog excerpts

F2A1X Frequency to Analog Converter/Tachometer Description The F2A1X Frequency to Analog module converts a frequency input signal into a proportional analog voltage (0‐5Vdc) or current (4‐20mAdc) output. The output signal is electrically isolated from input signal and input power source effectively eliminating troublesome ground loops. The input signal can be supplied from a Monarch sensor (measuring RPM for example) or any source of digital signal not exceeding 12 volts. The F2A1X is factory preprogrammed with the full scale output and input scale factor of your choice. These settings are also user configurable with the optional USB programming cable and PM Remote Software. PM Remote Software also displays data in real‐time and allows data to be stored directly to Microsoft Excel™. The F2A1X requires 12‐24Vdc input power. Economically priced Rugged, compact and lightweight Electrically Isolated input/output 5 to 600,000 RPM range (0.1 to 10kHz) Compatible with most speed sensors (TTL) User configurable* View real‐time data on PC* Store data in Excel File in real‐time* 4‐20mA or 0‐5Vdc scalable output 5 Vdc or 10 Vdc sensor supply (jumper selectable). Process monitoring Tachometer signal generator QC and R & D Engine performance Signal conditioning for data acquisition Motor or pump monitoring
Open the catalog to page 1
F2A1X Frequency to Analog Converter/Tachometer PM Remote Software PM Remote Software is a Windows™ based software application that allows the user to quickly and easily customize the configuration of the F2A1X. Set the mode of operation to RPM, RPS or Frequency and select the input scale (pulses per revolution). The isolated analog output is also fully scalable. The user can set the input pulse trigger , zero timeout and gate time. Real‐time data can be displayed directly on the PC along with Min and Max values. Decimal ...
Open the catalog to page 2
F2A1X Frequency to Analog Converter/Tachometer Specifications Input Range: Accuracy: Resolution: Dimensions: Power Supply: Inputs: Sensor Excitation: Recommended Sensors: Current Output Option: Voltage Output Option: Resolution: Environmental: Electrical Safety: 5 Vdc or 10 Vdc @ 75mA (user selectable jumper setting). Optical ‐ Monarch ROS‐W Proximity ‐ Monarch P5‐11 Infrared ‐ Monarch IRS‐W Laser ‐ Monarch ROLS‐W ...
Open the catalog to page 3
F2A1X Frequency to Analog Converter/Tachometer Ordering Information To specify your F2A1X: Select the input mode and analog output signal. Then specify the full scale output range of the analog output (the low will be set to zero). These ranges are factory pre‐set or can be user configured with the optional USB cable and PM Remote software.
Open the catalog to page 4All MONARCH INSTRUMENT catalogs and technical brochures
-
Instrument Brochure
24 Pages
-
Monarch Instrument Brochure
13 Pages
-
Proximity Sensor P5-11
1 Pages
-
illumiNova™
1 Pages
-
Track‐It™
2 Pages
-
Nova Strobe LED Strobes
2 Pages
-
Nova-Pro UV385 Data Sheet
2 Pages
-
Nova-Pro™
4 Pages
-
Nova-Strobe LED Strobes
2 Pages
-
ACT-1B
4 Pages
-
ACT-3X Panel Tachometer
4 Pages
-
DataChart DC1250 Brochure
4 Pages
-
Rugged Temperature Logger
2 Pages
-
RH/Temp Logger
2 Pages
-
Pressure/Temp Logger
2 Pages
-
DC Voltage/Current Logger
2 Pages
-
Temperature Logger
2 Pages
-
AC Event Logger
2 Pages
-
VPE Ultrasonic Leak Detector
2 Pages