| | | PHASEMASTER 6, 7 & 7S SPECIFICATIONS | | |
| | | |
| | | | | | | | | | | | PM6 | PM7/7S | | | | Control | NEMA type BS2HX synchronous welding control. | | | | Welding Functions | Sequence | 10 functions: sequence, sequence repeat, preheat/postheat, up/downslope, quench/temper, unbalanced Ac, rollspot, braze, continuous/seam, and basic weld. | | | | Line Voltage | Single phase 100,115,208,230, or 460 VAC, 50/60 Hz. Controls are shipped wired for 230 VAC unless otherwise specified. | | | | Output Current | 28 amps at 50%, 70 amps at 8%, 200 amps @1% duty cycle | | | | Weld Schedules | Operator can save (write) 8 different weld schedules. Schedule protection feature protects schedules 1 through 7 from unauthorized or inadvertent changes. | Operator can save (write) 128 different weld schedules. Schedule protection feature protects schedules 1 through 127 from unauthorized or inadvertent changes. | | | | Automatic Line Voltage Compensation | Compensates for line voltage changes of +/- 13% | | | | Power Factor Correction | Ensures that actual welding current is within +/- 3% of the value selected, regardless of the power factor of the load. | | | | Remote External Input Connectors | Provided for the following control signals: emergency stop input, remote weld inhibit, and remote weld schedule selection. Use dry | | | | | 24 and 115 VAC, 15 volt-amps to control a solenoid on an air actuated weld head. | Two (2) 24 and 115 VAC, 15 volt-amps to control a solenoid on either one or two air actuated weld heads. | | | | Relay Outputs | n/a | Two industrial relays, capable of switching up to 250mA. Relay 1 and relay 2 provide status signals to external devices. Relay 1 can switch a 24 to 115 VAC signal or be used to control a second 24 VAC air actuated weld head. Relay 2 can switch a 5 to 50 VDC signal. When used for status signals, these relays can be independently programmed to close (a) during any period of the weld sequence (b) when the PM7 is waiting for the weld sequence to start; and/or when an alarm occurs. | | | | Built-in Weld Counters | n/a | Allows user to control events which are a function of the number of welds which have been made. | | | | Weld Sentry | n/a | Optional. Measures weld voltage and current within user definable time windows. Analyzes results via built-in SPC. Refer to datasheet 991-091 for more information. | | | | | | | | | | |
| | | |
| | | PHYSICAL CHARACTERISTICS | | |
| | | |
| | | | | | | | | | | | PM6 | PM7 | | | | L x W x H Inches (mm) | 10 x 9 x 8 (254 x 229 x 203) | 13 x 11 x 9 (330 x 279 x 229) | | | | Weight Lbs. (Kg) | 15 (7) | 25 (11) | | | | | | | | | | |
| | | |
| | | IMPULSE TRANSFORMER SPECIFICATIONS Operate at a 50% duty cycle (30 welds per second) when the weld period is an integral number of cycles and up to 5 welds per second in unipolar, half-cycle operation. | | |
| | | |
| | | | | | | | | | | | | | | | | | | | Primary | Input | Input | | Output Voltage | Short Ckt. | Height | Width | Depth | Weight | | | | Model | Voltage | KVA @ 8% | KVA @ 50% | Prim/Sec | Range/Steps | Current | Inches (mm) | Inches (mm) | Inches (mm) | Lbs (Kg) | | | | X2/115RF | 115 | 1.9 | .75 | 4/0 | 3.8-1.0/4 | 2400 | 6.5 (165) | 6.5 (165) | 11.0 (279) | 20 (9) | | | | X2/230RF | 230 | 1.9 | .75 | 4/0 | 3.8-1.0/4 | 2400 | 6.5 (165) | 6.5 (165) | 11.0 (279) | 20 (9) | | | | X2/115 | 115 | 2.5 | 1.0 | 4/0 | 3.2-2.0/4 | 2300 | 6.5 (165) | 6.5 (165) | 11.0 (279) | 20 (9) | | | | X2/230 | 230 | 2.5 | 1.0 | 4/0 | 3.2-2.0/4 | 2300 | 6.5 (165) | 6.5 (165) | 11.0 (279) | 20 (9) | | | | | 115 | 4.5 | 1.8 | 4/2 | 14-1.8/24 | 1800 | 8.3 (211) | 6.6 (168) | 9.6 (244) | 60 (27) | | | | X5/115HV | 230 | 4.5 | 1.8 | 4/2 | 14-3.5/12 | 1800 | 8.3 (211) | 6.6 (168) | 9.6 (244) | 60 (27) | | | | X8/230 | 230 | 8.0 | 3.2 | 8/0 | 5.8-3.0/8 | 9200 | 13.0 (330) | 7.0 (178) | 14.0 (356) | 90 (41) | | | | X16/230 | 230 | 16.0 | 6.4 | 3/2 | 5.6-1.4/9 | 16000 | 13.0 (330) | 7.5 (191) | 14.0 (356) | 95 (43) | | | | X16/460 | 460 | 16.0 | 6.4 | 3/2 | 5.6-1.4/9 | 16000 | 13.0 (330) | 7.5 (191) | 14.0 (356) | 95 (43) | | | | | | | | | | | | | | | | | | |
| | | |
| | | ORDERING GUIDE | | |
| | | |
| | | | | | | | | | Specify PM6 or PM7 | Add/XXX for voltages other than 230 VAC where XXX is the line voltage. Example: PM6/115 for 115 VAC operation. | | | | Specify PM7S | For built-in Weld Sentry | | | | Required Accessories | Weld transformer, weld head, footpedal for manual heads, footswitch for air heads. | | | | | | | | | |
| | | |
| | | Spiritflflano vat/o/2„ MIYACHI QJJ 0^0=0= LB GC. Corporate Office: 1820 S. Myrtle Ave. • P.O. Box 5033 • Monrovia, CA 91017-7133 USA Tel: (626) 303-5676 • FAX: (626) 358-8048 • E-Mail: info@miyachiunitek.com Internet http://www.miyachiunitek.com • ISO 9001 Certified Company | | |
| | | Your Local Representative | | |
| | | |
| | | |
| | | EASTERN (USA) Sales Office: 170 Cross Street Boylston, MA 01505 Tel: (508) 869-0583 FAX: (508) 869-0585 E-Mail: eastsales@miyachiunitek.com | | ASIA Sales Office: Unit D, 20/F, Infotech Centre 21 Hung To Road Kwun Tong, Hong Kong Tel: +852 2833-6998 FAX: +852 2833-6672 | | UNITEK EAPRO: Schootense Dreef 21 NL-5708 HZ Helmond The Netherlands Tel: +31 492-54-22-25 FAX: +31 492-53-62-22 | | |
| | | CO CJD CXI o | | |
| | | |
| | | LO LO O 5J | | |
| | | Specifications subject to change without notice. Copyright© 2006 Miyachi Unitek Corporation. The material contained herein cannot be reproduced or used in any other way without the express written permission of Miyachi Unitek Corporation. All rights reserved. | | |
| | | |
| | | |
| | | |