PHASEMASTER 6, 7 & 7S SPECIFICATIONS
PM6 | PM7/7S
Control
NEMA type BS2HX synchronous welding control.
Welding Functions
Sequence
10 functions: sequence, sequence repeat, preheat/postheat, up/downslope, quench/temper, unbalanced Ac, rollspot, braze, continuous/seam, and basic weld.
Line Voltage
Single phase 100,115,208,230, or 460 VAC, 50/60 Hz. Controls are shipped wired for 230 VAC unless otherwise specified.
Output Current
28 amps at 50%, 70 amps at 8%, 200 amps @1% duty cycle
Weld Schedules
Operator can save (write) 8 different weld schedules. Schedule protection feature protects schedules 1 through 7 from unauthorized or inadvertent changes.
Operator can save (write) 128 different weld schedules. Schedule protection feature protects schedules 1 through 127 from unauthorized or inadvertent changes.
Automatic Line Voltage Compensation
Compensates for line voltage changes of +/- 13%
Power Factor Correction
Ensures that actual welding current is within +/- 3% of the value selected, regardless of the power factor of the load.
Remote External Input Connectors
Provided for the following control signals: emergency stop input, remote weld inhibit, and remote weld schedule selection. Use dry
relay contact or optocouplers.
Valve driver Outputs
24 and 115 VAC, 15 volt-amps to control a solenoid on an air actuated weld head.
Two (2) 24 and 115 VAC, 15 volt-amps to control a solenoid on either one or two air actuated weld heads.
Relay Outputs
n/a
Two industrial relays, capable of switching up to 250mA. Relay 1 and relay 2 provide status signals to external devices. Relay 1 can switch a 24 to 115 VAC signal or be used to control a second 24 VAC air actuated weld head. Relay 2 can switch a 5 to 50 VDC signal. When used for status signals, these relays can be independently programmed to close (a) during any period of the weld sequence (b) when the PM7 is waiting for the weld sequence to start; and/or when an alarm occurs.
Built-in Weld Counters
n/a
Allows user to control events which are a function of the number of welds which have been made.
Weld Sentry
n/a
Optional. Measures weld voltage and current within user definable time windows. Analyzes results via built-in SPC. Refer to datasheet 991-091 for more information.
PHYSICAL CHARACTERISTICS
PM6
PM7
L x W x H Inches (mm)
10 x 9 x 8 (254 x 229 x 203)
13 x 11 x 9 (330 x 279 x 229)
Weight Lbs. (Kg)
15 (7)
25 (11)
IMPULSE TRANSFORMER SPECIFICATIONS
Operate at a 50% duty cycle (30 welds per second) when the weld period is an integral number of cycles and up to 5 welds per second in unipolar, half-cycle operation.
Primary
Input
Input
Output Voltage
Short Ckt.
Height
Width
Depth
Weight
Model
Voltage
KVA @ 8%
KVA @ 50%
Prim/Sec
Range/Steps
Current
Inches (mm)
Inches (mm)
Inches (mm)
Lbs (Kg)
X2/115RF
115
1.9
.75
4/0
3.8-1.0/4
2400
6.5 (165)
6.5 (165)
11.0 (279)
20 (9)
X2/230RF
230
1.9
.75
4/0
3.8-1.0/4
2400
6.5 (165)
6.5 (165)
11.0 (279)
20 (9)
X2/115
115
2.5
1.0
4/0
3.2-2.0/4
2300
6.5 (165)
6.5 (165)
11.0 (279)
20 (9)
X2/230
230
2.5
1.0
4/0
3.2-2.0/4
2300
6.5 (165)
6.5 (165)
11.0 (279)
20 (9)
115
4.5
1.8
4/2
14-1.8/24
1800
8.3 (211)
6.6 (168)
9.6 (244)
60 (27)
X5/115HV
230
4.5
1.8
4/2
14-3.5/12
1800
8.3 (211)
6.6 (168)
9.6 (244)
60 (27)
X8/230
230
8.0
3.2
8/0
5.8-3.0/8
9200
13.0 (330)
7.0 (178)
14.0 (356)
90 (41)
X16/230
230
16.0
6.4
3/2
5.6-1.4/9
16000
13.0 (330)
7.5 (191)
14.0 (356)
95 (43)
X16/460
460
16.0
6.4
3/2
5.6-1.4/9
16000
13.0 (330)
7.5 (191)
14.0 (356)
95 (43)
ORDERING GUIDE
Specify PM6 or PM7
Add/XXX for voltages other than 230 VAC where XXX is the line voltage. Example: PM6/115 for 115 VAC operation.
Specify PM7S
For built-in Weld Sentry
Required Accessories
Weld transformer, weld head, footpedal for manual heads, footswitch for air heads.
Spiritflflano vat/o/2„
MIYACHI
QJJ 0^0=0= LB GC.
Corporate Office: 1820 S. Myrtle Ave. • P.O. Box 5033 • Monrovia, CA 91017-7133 USA Tel: (626) 303-5676 • FAX: (626) 358-8048 • E-Mail: info@miyachiunitek.com Internet http://www.miyachiunitek.com • ISO 9001 Certified Company
Your Local Representative
EASTERN (USA) Sales Office:
170 Cross Street
Boylston, MA 01505
Tel: (508) 869-0583
FAX: (508) 869-0585
E-Mail: eastsales@miyachiunitek.com
ASIA Sales Office: Unit D, 20/F, Infotech Centre 21 Hung To Road Kwun Tong, Hong Kong Tel: +852 2833-6998 FAX: +852 2833-6672
UNITEK EAPRO: Schootense Dreef 21 NL-5708 HZ Helmond The Netherlands Tel: +31 492-54-22-25 FAX: +31 492-53-62-22
CO CJD CXI
o
LO LO O
5J
Specifications subject to change without notice.
Copyright© 2006 Miyachi Unitek Corporation. The material contained herein cannot be reproduced or used in any other way without the express written permission of Miyachi Unitek Corporation. All rights reserved.
E-Mail: asiapacific@miyachiunitek.com E-Mail: info@unitekeapro.com
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-60