| Technical Data Accuracy: Refer to the list of specifications (excluding quantizing error) Resolution: 0.001mm, ,0000570.001mm or .000170.001mm Display: LCD Length standard: ABSOLUTE electrostatic capacitance type linear encoder Max. response speed: Unlimited Measuring force: 2.0N or less Stem dia.: 8mm (ISO/JIS type) or 3/8" (ANSI/AGD type) Contact point: Carbide ball with M2.5x0.45 (ISO/JIS type) Carbide ball with #4-48UNF (ANSI/AGD type) Power supply: DC12- 24V±10% Dust/Water protection level: IP54 Function Data output (-NG/OK/NG signal, NPN open collector), Remote control (hold-preset, preset-recall, zero-set), Orlgin-set/Preset, Zeroset, GO/±NG judgment, Max/MIn/ Runoutvalue holding, Counting direction switching, Power ON/OFF, inch/mm conversion (inch/mm models) Alarm: Low voltage, Counting value composition error, Over-flow error, Tolerance limit setting error Optional Accessory 902011: Spindle lifting lever* (ISO/JIS type) 902794: Spindle lifting lever* (ANSI/AGD type) 540774: Spindle lifting cable* 125317: Rubber boot ---: Backs (See page 266.) ---: Contact points (See page 264.) *When using the spindle lifting lever/cable, IP54 is not guaranteed. Output pattern |