Group: Mitsubishi
Catalog excerpts
OPERATING HANDLES FOR MITSUBISHI NO-FUSE CIRCUIT BREAKERS (MCCB)/ELECTRIC LEAKAGE CIRCUIT BREAKERS (ELCB)
Open the catalog to page 1Operating Handles for Mitsubishi MCCB/ELCB of Our product lineup includes operating handles for MCCB and ELCB of 800A frame or smaller which are used in equipment and power receiving/distribution panels supplied on the worldwide markets such as semiconductor/automobile manufacturing equipment and machine tools. We have incorporated our safety concept which changes in response to market globalization into our products’ specifications. At the same time, efforts have been made for standardization of specifications and increased mounting interchangeability with conventional products in order to...
Open the catalog to page 2“Safety” & Flexibility 800A Frame or Smaller Characteristics of Products F-type Operating Handles Standardization of OFF Lock Specifications As locking is possible only in the OFF position (power disconnected position), increased safety is achieved. Supporting Various Lockout Devices Our operating handles can support not only padlocks but also lockout latches (scissors lock). * The ON/OFF lock specification is also available to order. Safety V-type Operating Handle Supporting Locking of Operating Section V-type Operating Handle Warning Indication of Adjustment Shaft Added The operating...
Open the catalog to page 3F-type Operating Handle (Breaker Mount Type) Breaker Mount Type of Operating Handle Attached on Circuit Breaker Body Conforming to the safety standard of EN Standards (EN 60204-1). Offering circuit disconnecting (isolating) function in combination with the breaker body. Degrees of protection (IEC 60529) is IP54. Also available in UL489 listed products. Door Lock Mechanism Safety Device The standard product complies with the reset open specification. The panel door can be opened only by the open (reset) operation performed. The panel door can also be opened in ON or OFF position when the...
Open the catalog to page 4“Safety” & Flexibility Outside Dimension Drawing Front Plate Drilling Dimension Drawing Front plate Packing Center of circuit breaker and operating handle Center of circuit breaker and operating handle Center of circuit breaker Center of circuit breaker and operating handle Center of operating handle Outside Dimension Drawing Circuit Breaker Mounting-Hole Drilling Dimension Drawing Left hinge Center of circuit breaker handle Hinge (right) Hinge (left) Center of circuit breaker and operating handle Operating handle Front plate Less than 10 170 or more 10 or 5H+120 more or more Circuit...
Open the catalog to page 5F-type Operating Handle (Breaker Mount Type) Outside Dimension Drawing 400~800A Frame Front Plate Drilling Dimension Drawing Outside Dimension Drawing Center of circuit breaker and operating handle Decorated plate Front plate Center of circuit breaker Center of operating handle 112 Interlock release screw Circuit Breaker Mounting-Hole Drilling Dimension Drawing Center of circuit breaker handle Center of Hinge and Circuit Breaker Left hinge Operating handle Front plate Circuit breaker 0 or more Center of circuit breaker and operating handle Hinge (left) Hinge (right) Circuit breaker * The...
Open the catalog to page 6Mount & Flexibility V-type Operating Handle (Door“Safety”Type) Door mount type of operating handle for which operating section is Attached on breaker body and operating handle on panel door Conforming to the safety standard of EN Standards (EN 60204-1). Offering disconnecting (isolating) function in combination with the breaker body. Degrees of protection (IEC 60529) is IP54. Mountable on the 2-pole breaker. Operating handle for the 3-pole breaker also usable with the 4-pole breaker. Door Lock Mechanism The panel door can be opened in the OFF position. In the ON and TRIP position, the panel...
Open the catalog to page 7V-type Operating Handle (Door Mount Type) Outside Dimension Drawing 250A Frame or Smaller Front Plate Mounting-Hole Drawing Outside Dimension Drawing Front plate Center of circuit breaker and operating handle Center of circuit breaker and operating handle f9 f9 Center of Center of operating handle circuit breaker Center of circuit breaker Center of operating handle Center of hinge and circuit breaker Plate thickness 1.2 to 3.2 * The right drawing shows a layout of the hinge and the circuit breaker when viewed from the load side. Center of circuit breaker Center of circuit breaker and...
Open the catalog to page 8“Safety” & Flexibility Outside Dimension Drawing 400~800A Frame Front Plate Mounting-Hole Drawing Outside Dimension Drawing A Center of circuit breaker and operating handle 4- 10 Front plate Center of circuit breaker Center of operating handle Circuit Breaker Mounting-Hole Drilling Drawing 4-pole Front plate Center of hinge and circuit breaker H Center of circuit breaker and operating handle Hinge (left) Hinge (right) Circuit breaker * The right drawing shows a layout of the hinge and the circuit breaker when viewed from the load side. Summary of Dimensions Applicable models (Note 1) Type...
Open the catalog to page 9Comparison of Previous and New Models Breaker type MCCB General products ELCB General Conventional type F- products New type type UL listed Conventional type products New type General Conventional type V- products New type type UL listed Conventional type products New type No additional machining required No additional machining required No additional machining required No additional machining required No additional machining required No additional machining required Breaker mounting-hole dimension No additional machining required No additional machining required No additional machining...
Open the catalog to page 10Breaker type MCCB General products ELCB NF-SFW, NF-SJW, NF-HJW UL listed products General Conventional type F1UW F- products New type F-1U type UL listed Conventional type products New type General Conventional type V1UW, V1UWF V- products New type V-1U type UL listed Conventional type – products New type – No additional machining required No additional machining required No additional machining required No additional machining required No additional machining required No additional machining required No additional machining required No additional machining required Breaker mounting-hole...
Open the catalog to page 11All MITSUBISHI ELECTRIC AUTOMATION catalogs and technical brochures
-
MELFA Family
64 Pages
-
Compact PLC Family Catalogue
122 Pages
-
HMI-Family Visualisation Tools
90 Pages
-
MELFA Family
64 Pages
-
The Automation Book
156 Pages
-
MELSEC iQ-R series/System Q/L series
152 Pages
-
QS90SR2SP
4 Pages
-
FX3UC
4 Pages
-
L Series
4 Pages
-
FX Family
88 Pages
-
Q/L-Family
114 Pages
-
COGNEX
2 Pages
-
MELSEC iQ-F SERIES
2 Pages
-
ME96-NSR
32 Pages
-
ME96-SS Series
32 Pages
-
ECOWEBSERVER III
16 Pages
-
PRODUCT OVERVIEW
2 Pages
-
POWER & ENERGY PORTFOLIO
2 Pages
-
RV-2SD-SQ BROCHURE Ver. B
3 Pages
-
FX3S Brochure
6 Pages
-
GT14 Handy GOT Brochure
2 Pages
-
CNC DRIVES GENERAL CATALOG (V-M)
11 Pages
-
FX3GE Brochure
2 Pages
-
GT16 Handy Brochure
2 Pages
-
FX3U-ENET-ADP Brochure
4 Pages
-
RV-SQ-RH-SQH BROCHURE Ver. B
4 Pages
-
ME96-SS Series Brochure
32 Pages
-
GT14 Brochure
3 Pages
-
F920GOT F930GOT Brochure
2 Pages
-
FX2NC-ENET-ADP Brochure
2 Pages
-
FX3U-1PG Brochure
2 Pages
-
LOW VOLTAGE SWITCHGEAR
12 Pages
-
MR-MQ100 Single Axis Motion
4 Pages
-
LD77MH Simple Motion Module
12 Pages
-
ST Series
4 Pages
-
GOT1000
13 Pages
-
F900
16 Pages
-
E1000
12 Pages
-
QE81-WH Energy Module
8 Pages
-
ME96-NSR Energy Meter
32 Pages
-
CC-Link
29 Pages
-
EnergyPAQ
2 Pages
-
M70 Series
8 Pages
-
C70 Series For iQ Platform
19 Pages
-
M700V Series
11 Pages
-
WS Series Circuit Breaker
192 Pages
-
WS-V Series
260 Pages
-
QS Safety PLC and CC-Link Safety
56 Pages
-
Q Series
31 Pages
-
MES Interface IT
7 Pages
-
Q Series Redundant System
31 Pages
-
iQ Sequence Controller
33 Pages
-
Inverter family
20 Pages
Archived catalogs
-
Programmable Logic Controllers
28 Pages
-
MELFA Industrial Robots
50 Pages
-
Frequency Inverters
8 Pages
-
Global and open Field Network
12 Pages
-
Control Units
8 Pages
-
Melsec PLC
85 Pages