video corpo

FX3S Brochure
6Pages

{{requestButtons}}

Catalog excerpts

FX3S Brochure - 1

PROGRAMMABLE CONTROLLERS 50/60 Hz Operation can be continued upon occurrence of instantaneous power failure for 10 ms or less. 250 V 1 A 15 A max. 5 ms or less/100 V AC, 28 A max. 5 ms or less/200 V AC Power consumption*1 19 W 19 W 20 W 21 W 24 V DC service power 400 mA supply High-end Model *1 : This item shows values when all 24 V DC service power supplies are used in the maximum configuration connectable to the main unit, and includes the input current (5 or 7 mA per point). Superior speed, power, and flexibility. Realize high speed control, network support, data logging, and more. ■24 V DC Input (sink/source) specifications (Please see the manual for input circuit configuration.) Item Number of input points Input connecting type Input form Input signal voltage Input X000 to impedance X007 X010 to X017 Input signal X000 to current X007 X010 to X017 ON input X000 to sensitivity X007 current X010 to X017 OFF input sensitivity current Input response time Input signal Sink input form Source input Input circuit insulation Input operation display Standard Model From automation to network, to more advanced control. Supports features required for basic control and a variety of applications. Entry level Model FX3 series is the 3rd generation of micro programmable controllers. Extension Extension High speed, large capacity, and enhanced performance and 10 Equipped with excellent expandability for analog, communication, Ethernet, and positioning functions, a whole world of FX applications awaits. 1.5 mA or less Approx. 10 ms No-voltage contact input NPN open collector transistor No-voltage contact input PNP open collector transistor Photocoupler insulation LED on panel lights when photocoupler is driven. Relay output specification FX3S FX3S FX3S FX3S 10MR/ES 14MR/ES 20MR/ES 30MR/ES Number of output points 4 points 6 points 8 points 14 points Output connecting type Fixed terminal block (M3 screw) Output form Relay External power supply 30 V DC or less, 240 V AC or less (250 V AC or less when the unit does not comply with CE, UL or cUL standards.) Max. load Resistance 2 A/point The total load current of resistance loads per load common terminal should be the following value. • 1 output point/common terminal: 2 A or less • 4 output points/common terminal: 8 A or less Inductive 80 VA (UL and cUL standards approved at 120 and load 240 V AC.) Min. load 5 V DC, 2 mA (reference value) Open circuit leakage current — Response OFF→ON Approx. 10 ms time ON→OFF Output circuit insulation Mechanical insulation Output operation display LED on panel lights when power is applied to relay coil. ■Transistor output specifications (Please see the manual for output circuit configuration.) Item Number of output points Output connecting type Output form Number of control points External power supply Max. load Resistance load Inductive load Main unit I/O Control size 14/24/40/60 points Max. 128 points (Max. 256 with remote I/O*) 16/32/48/64/80/128 points Max. 256 points (Max. 384 with remote I/O*) Power supply Relay Type Transistor Type Relay Type Transistor Type Relay Type Transistor Type Internal memory 16,000 steps EEPROM (program capacity is limited to 4,000 steps.) 64,000 steps RAM (Battery backed) Communication port High-speed counter Positioning control (transistor output type) 14/24 Point type : 2 axes 40/60 Point type : 3 axes 100 kHz (Mounting hole pitches) PROGRAMMABLE CONTROLLERS Accessories : Dust proof protection sheet Manual supplied with product Installation : 35 mm (1.38") wide DIN rail or Direct installation (with M4 screws) W1: mm (inches) Direct mounting hole pitches ■Product specification Series Main Units Power Supply Input Specifications Output Specifications Number of Number of Input type points points 6 6 Output type Transistor (Sink) Transistor (Source) Transistor (Sink) Transistor (Source) Transistor (Sink) Transistor (Source) Transistor (Sink) Transistor (Source) Connector conversion adapter Special adapter connection conversion adapter Special adapters 2-ch voltage/current input 1-ch voltage/current output FX3U -4AD-PT-ADP 4-ch platinum resistance thermometer sensor input (-50 to +250 ℃) FX3U -4AD-PTW-ADP 4-ch platinum resistance thermometer sensor input (-100 to +600 ℃) FX3U -4AD-PNK-ADP 4-ch Pt1000/Ni1000 resistance thermometer sensor input FX3U -4AD-TC-ADP 4-ch thermocouple (K, J type) temperature sensor input Expansion boards FX3G -EEPROM-32L 32,000 steps EEPROM memory (with transfer switch)*5 *4 : FX3U -ENET-ADP Ver. 1.20 or later is applicable to the FX3S series PLC. *5 : FX3S series PLC can hold 16,000 steps of memory, but user program capacity is limited to 4000 steps. − Introducing an entry level model for the FX3 series − Variable analog potentiometer Performance Stored program repetitive operation system with interruption function. Input/output control system Batch processing system (when END instruction is executed) Input/output refresh instruction and pulse catch function are provided. Programming language Relay symbol system + step-ladder system (SFC notation possible) Program Built-in memory capacity/ 16,000 steps/EEPROM memory (Program capacity is 4000 steps.) memory type Max. allowable write: 20,000 times Memory cassette 32,000 steps/EEPROM memory (with loader function) (Option) The FX3S series PLC is available only to 16,000 steps. (Program capacity is 4000 steps.) Max. allowable write: 10,000 times Writing function during Provided (Program can be modified while the PLC is running running.) Keyword function With keyword/Customer keyword function Real-time Clock function*2 Built-in 1980 to 2079 (with correction for leap year) clock 2- or 4-digit year, accuracy within 45 seconds/month at 25 ℃ Kinds of Basic instructions Sequence instructions: 29 Step-ladder instructions: 2 instructions Applied instructions 116 kinds Processing Basic instructions 0.21 μs/instruction speed Applied instructions 0.5 μs to several hundred μs/instruction Number of Input points 16 points or less (Extension is impossible.) input/output Output points 14 points or less (Extension is impossible.) points Input/output Input relay X000 to X017 The device numbers are octal. relay Output relay Y000 to Y015 Auxiliary For general M0 to M383 384 points relay EEPROM keep M384 to M511 128 points For general M512 to M1535 1024 points For special M8000 to M8511 512 points State For initial state S0 to S9 10 points (EEPROM keep) EEPROM keep S10 to S127 118 points For general S128 to S255 128 points Timer 100 ms T0 to T31 32 points 0.1 to 3,276.7 sec (on-delay 100 ms/10 ms T32 to T62 31 points 0.1 to 3,276.7 sec/0.01 to timer) 327.67 sec When M8028 is driven ON, timers T32 to T62 (31 points) are changed to 10 ms resolution. 65 points 0.001 to 32.767 sec 1 ms T63 to T127 1 ms accumulating type T128 to T131 4 points 0.001 to 32.767 sec 100 ms accumulating type T132 to T137 6 points 0.1 to 3,276.7 sec Variable analog potentiometers Available as analog timers VR1: D8030 VR2: D8031 C0 to C15 16 points Counting from 0 to 32,767 Counter 16 bits up (For general) 16 bits up (EEPROM keep) C16 to C31 16 points Counting from 0 to 32,767 32 bits up/down (For C200 to C234 35 points Counting from general) -2,147,483,648 to +2,147,483,647 High1-phase 1-count input in C235 to C245 Counting from -2,147,483,648 to both directions (32 bits +2,147,483,647 speed up/down) counter (EEPROM keep) 1-phase 2-count input in C246 to C250 both directions (32 bits up/down) (EEPROM keep) 2-phase 2-count input in C251 to C255 both directions (32 bits up/down) (EEPROM keep) For general (16 bits) D0 to D127 128 points Data register For EEPROM keep (16 bits) D128 to D255 128 points (32 bits For general (16 bits) D256 to D2999 2744 points when File register D1000 to D2999 Max. Can be set as file registers paired) (EEPROM keep) 2000 in units of points 500 points from D1000 in the program area (EEPROM) using parameters. D8000 to D8511 512 points For special (16 bits) For index (16 bits) V0 to V7 16 points Z0 to Z7 Pointer For branching of JUMP P0 to P255 256 For CJ instructions and and CALL points CALL instructions 6 points Input interruption I0 to I5 Timer interruption I6 to I8 3 points Nesting For master control N0 to N7 8 points For MC instructions Constant Decimal number (K) 16 bits -32,768 to +32,767 32 bits -2,147,483,648 to +2,147,483,647 Hexadecimal number (H) 16 bits 0 to FFFF 32 bits 0 to FFFFFFFF Real number (E) 32 bits -1.0 x 2128 to -1.0 x 2-126 , 0 , 1.0 x 2-126 to 1.0 x 2128 Decimal-point and exponential notations are possible. Software/peripheral equipment GX Works2 Version 1.492N or later *3 Version 1.50 or later FX-30P Transistor output specification FX3S FX3S FX3S FX3S 10MT□ 14MT□ 20MT□ 30MT□ 4 points 6 points 8 points 14 points Fixed terminal block (M3 screw) Transistor/sink output (FX3S -□MT/ES) Transistor/source output (FX3S -□MT/ESS) 5 to 30 V DC 0.5 A/point The total load current of resistance loads per common terminal should be the following value. • 1 output point/common terminal: 0.5 A or less • 4 output points/common terminal: 0.8 A or less 12 W/24 V DC The total of inductive loads per common terminal should be the following value. • 1 output point/common terminal: 12 W or less/ 24 V DC • 4 output points/common terminal: 19.2 W or less/24 V DC 0.1 mA or less/30 V DC 1.5 V or less Y000, Y001: 5 μs or less/10 mA or more (5 to 24 V DC) Y002 to Y015: 0.2 ms or less/200 mA or more (at 24 V DC) Photocoupler insulation LED on panel lights when photocoupler is driven. Item Operation control system Number of control points Built-in features ■Relay output specifications (Please see the manual for output circuit configuration.) Simple and cost effective. Basic model that supports analog and communication expansion. Perfect for simple automation tasks. FX3 series feature comparison ■External Dimensions Supply voltage Allowable supply voltage range Rated frequency Allowable instantaneous power failure time Power fuse Rush current ■Performance specifications (General specification is the same as that of FX3U series. Please see the "MELSEC FX-FAMILY" catalog.) 82 (3.23'') (Mounting hole pitches) ■Power Supply Specifications Open circuit leakage current ON voltage Response OFF→ON time ON→OFF Output circuit insulation Output operation display *2 : The current time of the clock is backed up by the capacitor built-in the PLC. Supply the power to the PLC for 30 minutes or more to completely charge this large-capacity capacitor. (The capacitor works for 10 days [atmosphere: 25 °C]) *3 : To program FX3S in GX Developer, select FX3G as the PLC type. Please read the FX3S series user's manual about limitations. Safety Warning To ensure proper use of the products in this document, please be sure to read the instruction manual prior to use. ••Ethernet is a trademark of Xerox Corporation in the United States. ••MODBUS is a registered trademark of Schneider Electric SA. ••All other company names and product names used in this document are trademarks or registered trademarks of their respective companies. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN * : Remote I/O is CC-Link I/O. HIME-L063-A1305(MEE) Printed in Japan New publication, effective May 2013 Specifications subject to change without notice.

Open the catalog to page 1

All MITSUBISHI ELECTRIC AUTOMATION catalogs and technical brochures

  1. MELFA Family

    64 Pages

  2. MELFA Family

    64 Pages

  3. QS90SR2SP

    4 Pages

  4. FX3UC

    4 Pages

  5. L Series

    4 Pages

  6. FX Family

    88 Pages

  7. Q/L-Family

    114 Pages

  8. COGNEX

    2 Pages

  9. ME96-NSR

    32 Pages

  10. ME96-SS Series

    32 Pages

  11. ST Series

    4 Pages

  12. GOT1000

    13 Pages

  13. F900

    16 Pages

  14. E1000

    12 Pages

  15. CC-Link

    29 Pages

  16. EnergyPAQ

    2 Pages

  17. M70 Series

    8 Pages

  18. M700V Series

    11 Pages

  19. WS-V Series

    260 Pages

  20. Q Series

    31 Pages

Archived catalogs

  1. Melsec PLC

    85 Pages