FX3GE Brochure - 1

PROGRAMMABLE CONTROLLERS Item Ambient temperature Ambient humidity Vibration resistance* With the launch of FX3S, Mitsubishi's FX3 series line of microcontrollers is finally completed. Whatever your requirements may be, you will be sure to find just the right PLC you need. Push the limits of control with FX3 series PLCs. Functionality When installed directly Noise durability Superior speed, power, and flexibility. Realize high speed control, network support, data logging, and more. Frequency (Hz) When installed on DIN rail Shock resistance* Dielectric withstand voltage Insulation resistance Grounding Working atmosphere Working altitude Item Power Supply Allowable instantaneous power failure time Power fuse Rush current Specifications 0 to 55°C (32 to 131°F) when operating and -25 to 75°C (-13 to 167°F) when stored 5 to 95%RH (no condensation) when operating Sweep Count for X, Y, Z: 10 times (80 min in each direction) Power consumption 24V DC service power supply External dimensions 2-f4.5 mounting holes 147m/s Acceleration, Action time: 11ms, 3 times by half-sine pulse in each direction X, Y, and Z By noise simulator at noise voltage of 1,000Vp-p, noise width of 1ms, rise time of 1ns and period of 30 to 100Hz 1.5kV AC for one minute, 500VAC for one minute 5MΩ or more by 500V DC megger Class D: Grounding resistance 100Ω or less Free from corrosive or flammable gas and excessive conductive dusts <2000m lineup complete! Power Supply Specifications General specifications Model name 86 (3.39") Mounting hole pitches W1 : mm(inches) MASS(Weight) : kg(ibs) Direct mounting hole pitces 105(4.13") 0.60(1.32lbs) 150(5.90") 0.80(1.76lbs) ‧35-mm-wide DIN rail or Direct (screw) mounting (M4) From automation to network, to more advanced control. Supports features required for basic control and a variety of applications. Item I/O points Address range Program memory Simple and cost effective. Basic model that supports analog and communication expansion. Perfect for simple automation tasks. FX3 series overview Main unit I/O Control size Terminal Power supply 24V DC input Output Shipping approvals Internal memory RTC Battery Communication ports High speed counters 10/14/20/30 I/O Max. 30 Screw AC Sink/Source Relay/Transistor — 16k steps EEPROM program memory : 4k steps Built-in — USB, RS-422 1 phase 60kHz : 2 10kHz : 4 2 axes 100kHz — 2 Expansion boards Special adapters Analog I/O Analog volume Memory cassette Display module CC-Link V2 MODBUS® Ethernet SSCNET III 14/24/40/60 I/O Max. 128 (Max.256 with CC-Link) Screw AC/DC Sink/Source Relay/Transistor P 24/40 I/O Max. 128 (Max.256 with CC-Link) Screw AC Sink/Source Relay — 16/32/48/64/80/128 I/O Max. 256 (Max.384 with CC-Link) Screw AC/DC Sink/Source Relay/Transistor P Auxiliary relays Special auxiliary relays State relays 4,096 total, with 1,000 EEPROM latched (S0 - S999) and 3,096 general/optional latched (S1000 - S4095) External setpoint entry via potentiometer High-speed counters High-speed counter speed Real-time clock Year, month, day, hour, minute, second, day of the week Data registers Extension registers Extension file registers Index registers Special data registers *1: Each value inside ( ) indicates the number of occupied points. Interrupt inputs 16 bit: K: -32,768 to +32,767; H: 0 to FFFF; 32 bit: K: -2,147,483,648 to +2,147,483,647; H: 0 to FFFF FFFF FX3GE -24MR/ES FX3GE -40MR/ES 256 total (combined local and CC-Link remote I/O) Max. 128 direct addressing and Max. 128 remote I/O 32,000 steps EEPROM (internal),exchangeable EEPROM memory cassette Instruction Time 0.21μs or 0.42μs / contact instruction Number of instructions 29 sequence instructions, 2 step ladder instructions, 124 applied instructions Programming language Step ladder, instruction list, SFC Step ladder Program execution Cyclical execution, refresh mode processing Program protection 2 different keywords, Max password length 16 characters Inputs Number of input points 14 24 Input signal voltage / form 24V DC +10%, -10%, Sink / Source Input signal current/ X000 to X007 : 7mA/24V DC, 3.3kΩ / impedance X010 or more : 5mA/24V DC, 4.3kΩ Outputs Number of output points 10 points (16 points)*1 16 Output type Relay Relay External power supply 30V DC or less, 240V AC or less*2 Max. Resistance load 2A : 1point common, 8A : 4points common Analog Input range Voltage input : 0V to 10V DC, 198.7kΩ(Max. -0.5V, +15V) inputs Current input : 4mA to 20mA DC, 250Ω(Max. -2mA, +30mA) Resolution Voltage input : 2.5mV (10V/4000), Current input : 5μA (16mA/3200) Analog Output range Voltage output : 0V to 10V DC (External load: 2k to 1MΩ) outputs Current output : 4mA to 20mA DC (External load: 500Ω or less) Resolution Voltage output : 2.5mV(10V/4000), Current output : 4μA(16mA/4000) Ethernet Data transmission speed 100Mbps / 10Mbps Communication method Full-duplex / Half-duplex Transmission method Base band Maximum segment length 100m (328’1) Safety Warning To ensure proper use of the products in this document, please be sure to read the instruction manual prior to use. ••Ethernet is a trademark of Xerox Corporation in the United States. ••MODBUS is a registered trademark of Schneider Electric SA. ••All other company names and product names used in this document are trademarks or registered trademarks of their respective companies. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN New publication, effective Apr. 2013 Specifications subject to change without notice. PROGRAMMABLE CONTROLLERS

Open the catalog to page 1
FX3GE Brochure - 2

All-in-one standard! including analog and network features FX3GE adds built-in analog input/output and Ethernet connectivity on top of FX3G performance. Take this flow control application A great fit for many applications. in the food industry for example. Built-in analog input Liquid level sensor Current Output Type 4-20mA Motor Pump Inverter Voltage Input Type 0-10V DC In addition to its built-in features, FX3GE also has a wealth of expansion options. Choose from the same options for FX3G/FX3U. Expansion boards and Special adapters Communication and analog special adapters 1 level :...

Open the catalog to page 2

All MITSUBISHI ELECTRIC AUTOMATION catalogs and technical brochures

  1. MELFA Family

    64 Pages

  2. MELFA Family

    64 Pages

  3. QS90SR2SP

    4 Pages

  4. FX3UC

    4 Pages

  5. L Series

    4 Pages

  6. FX Family

    88 Pages

  7. Q/L-Family

    114 Pages

  8. COGNEX

    2 Pages

  9. ME96-NSR

    32 Pages

  10. ME96-SS Series

    32 Pages

  11. ST Series

    4 Pages

  12. GOT1000

    13 Pages

  13. F900

    16 Pages

  14. E1000

    12 Pages

  15. CC-Link

    29 Pages

  16. EnergyPAQ

    2 Pages

  17. M70 Series

    8 Pages

  18. M700V Series

    11 Pages

  19. WS-V Series

    260 Pages

  20. Q Series

    31 Pages

Archived catalogs

  1. Melsec PLC

    85 Pages