Group: Mitsubishi
Catalog excerpts
litsubishi Electric Energy-saving Data Collection Server for a greener tomorrow ISSS Data) llajfia^tmtirlt l^luM^n
Open the catalog to page 1It Doesn’t Get Any Easier… Simplify data management with the Eco To ensure effective energy savings, it is important that every person is aware of how energy is being used and participating in conservation measures. An essential part of promoting a high awareness is making activities clearly visible — something we call “visible management” — which is realized by sharing the energy consumption data of specific divisions over the Web via the Intranet. Mitsubishi Electric’s EcoWebServer# is a simple, convenient and compact energy-saving data collection server developed to support visible...
Open the catalog to page 2WebServer# Example System Configuration Transfers files in CSV format Notification of abnormal operating status (less/more than upper/lower limits) Automatic clock adjustment SMTP server SNTP server Various Screen Display Functions for Simplified Energy-saving Data Analysis Easily view desired data on various display screens via mouse operation. Planned and target values can be set on a nearby computer. Specific consumption conveniently displayed in graph form for energy-saving data analysis. Use the mouse or keyboard operation and accompanying set-up software to easily set data, save...
Open the catalog to page 3Example Display Screens Daily Graph: Visual Display of Measurements · Switch between display formats to compare the same measuring point on different days or different measuring point on the same day. · As a result, users can see changes (abnormal values) in energy consumption and confirm the effect of energy-saving measures by comparing figures before and after measures are implemented. qPower consumption/No. of pulses screen Display data update button Display format selection box · Use the checkboxes to switch the format between displaying the same data for different dates (up to six...
Open the catalog to page 4Daily Graph (Specific Consumption Screen): Understand Power Consumption per Product · Assists enhancing productivity by clearly displaying specific consumption for products using a line graph with numerical values. · Confirm the effect of energy-saving measures by comparing specific consumption graphs before and after measures are implemented. Target value setting window button Display date selection menu · Set the target value for each measuring point from the specific consumption screen. · Changes to target value settings are password-protected. *Changes are password-protected to prevent...
Open the catalog to page 5@ Weekly Specific Consumption Graph Screen Managing specific consumption using weekly overviews simplifies analysis (e.g.. easily detect low productivity days —► conduct detailed analysis), and reduces time and effort involved in activities to promote energy-savings/improve productivity. 0 Fixed Scale Mode for Specific Consumption Graph normal display, useful for improving productivity. Confirm productivity details in fixed display, useful for production planning incorporating energy-saving initiatives. 'Current Value Display: Differential Display Mode previous hour to the present ©Current...
Open the catalog to page 6(J) Data File: Easily Collect Measurement Data According to Application • Upload desired measurement data to a personal computer using existing LAN network equipment. • Measurement data is saved in CSV format, enabling it to be used in spreadsheet software such as Microsoft Excel. • Easy to create documents relating to energy-saving activities using this feature. ©Daily data <Sample data: daily data> (D Data Settings: Easily Perform Settings using Mouse Operation *For data settings, please use the set-up software supplied with the product. ©Main menu screen ©Measuring points list screen...
Open the catalog to page 7Application Examples Factories Support Energy-saving Activities using “Visible Management”. 1. Monitor/Manage energy by department 2. Specific consumption-based management of energy-saving activities 3. Monthly/Annual target-based management 4. Monitoring of equipment operating status 5. Manage/Record energy data To monitor equipment status… mail Oh, an e- an alarm notifying of n line A. Alarm tio in produc Did we achieve the target this month? Oh no! ion has Consumpt mpared co increased . to last year Office Administration Department Measurement data Production Department · Air...
Open the catalog to page 8Application Examples Buildings Building No. 1 Electronic multi-measuring instrument Electronic multi-measuring instrument Significantly reduce installation cost by using the existing LAN. 1. Manage/Monitor energy by floor/application 2. Manage data remotely 3. Easy for tenants and other personnel to read meters 4. Monitor operating status of building facilities (e.g., elevators, escalators, air conditioners) 5. Record/Manage energy data 20F Office automation equipment We need to use the air conditioner less this month. Building management (management company) ws! Good ner has 20th floo...
Open the catalog to page 9Specifications Hardware Specifications Item Input power source Input frequency Input voltage distortion-factor Consumption VA Tolerated short interruption time Within 20ms (more than 100VAC) Operating ambient temperature Storage ambient temperature Operating ambient humidity Storage ambient humidity Operating environment Operating altitude Installation location Weight No corrosive gases 2,000m or lower Inside panel 0.9kg Power source section Built-in (cannot be replaced) Application Turns off when the power supply is not input or reset, or when the fuse is disconnected Rated switching...
Open the catalog to page 10Software Specifications Item Recommended operating environment Total measuring points 255 (including a max. of 32 operation monitoring points) Virtual measuring points Specific consumption measuring points Equipment points Logging functions Collect data for: every minute, every hour or 30 minutes, a specified hour once a day, a specified hour on a specified day every month Virtual measuring points Basic arithmetic operations for up to 16 operands with parentheses Specific consumption measuring points Divides the energy consumed by production quantit y (specif y Computes the data collected...
Open the catalog to page 11All MITSUBISHI ELECTRIC AUTOMATION catalogs and technical brochures
-
MELFA Family
64 Pages
-
Compact PLC Family Catalogue
122 Pages
-
HMI-Family Visualisation Tools
90 Pages
-
MELFA Family
64 Pages
-
The Automation Book
156 Pages
-
MELSEC iQ-R series/System Q/L series
152 Pages
-
QS90SR2SP
4 Pages
-
FX3UC
4 Pages
-
L Series
4 Pages
-
FX Family
88 Pages
-
Q/L-Family
114 Pages
-
COGNEX
2 Pages
-
MELSEC iQ-F SERIES
2 Pages
-
ME96-NSR
32 Pages
-
ME96-SS Series
32 Pages
-
PRODUCT OVERVIEW
2 Pages
-
POWER & ENERGY PORTFOLIO
2 Pages
-
RV-2SD-SQ BROCHURE Ver. B
3 Pages
-
FX3S Brochure
6 Pages
-
GT14 Handy GOT Brochure
2 Pages
-
CNC DRIVES GENERAL CATALOG (V-M)
11 Pages
-
FX3GE Brochure
2 Pages
-
GT16 Handy Brochure
2 Pages
-
FX3U-ENET-ADP Brochure
4 Pages
-
RV-SQ-RH-SQH BROCHURE Ver. B
4 Pages
-
ME96-SS Series Brochure
32 Pages
-
GT14 Brochure
3 Pages
-
F920GOT F930GOT Brochure
2 Pages
-
FX2NC-ENET-ADP Brochure
2 Pages
-
FX3U-1PG Brochure
2 Pages
-
LOW VOLTAGE SWITCHGEAR
12 Pages
-
Safety & Flexibility
16 Pages
-
MR-MQ100 Single Axis Motion
4 Pages
-
LD77MH Simple Motion Module
12 Pages
-
ST Series
4 Pages
-
GOT1000
13 Pages
-
F900
16 Pages
-
E1000
12 Pages
-
QE81-WH Energy Module
8 Pages
-
ME96-NSR Energy Meter
32 Pages
-
CC-Link
29 Pages
-
EnergyPAQ
2 Pages
-
M70 Series
8 Pages
-
C70 Series For iQ Platform
19 Pages
-
M700V Series
11 Pages
-
WS Series Circuit Breaker
192 Pages
-
WS-V Series
260 Pages
-
QS Safety PLC and CC-Link Safety
56 Pages
-
Q Series
31 Pages
-
MES Interface IT
7 Pages
-
Q Series Redundant System
31 Pages
-
iQ Sequence Controller
33 Pages
-
Inverter family
20 Pages
Archived catalogs
-
Programmable Logic Controllers
28 Pages
-
MELFA Industrial Robots
50 Pages
-
Frequency Inverters
8 Pages
-
Global and open Field Network
12 Pages
-
Control Units
8 Pages
-
Melsec PLC
85 Pages