Catalogue Sensors & Instruments Solutions Guide
www.minco.com
print switch display
Page / 164
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
MINCO - 2068, 41353
/ 164
See other catalogues for MINCO
Text version of the page
Accuracy: Includes linearity, hysteresis, repeatability, and voltage effects. Humidity: ±2.5% from 10% to 80% RH @ 25°C, ±3.5% from 80% to 90% RH @ 25°C.Temperature: ±0.5°F(0.27°C) @ 77°F (25°C) or +/- 0.75% of span,whichever is greater.

Accessories:

Sintered Filter Replacement Part Number: AC103512Slotted Filter Replacement Part Number: AC103513 Pipe Mounting Kit for AH72/AH73Part Number: AC1027 6 5Wall Mounting Kit for AH71Part Number: AC1031 6 8Duct Mounting Kit for AH71Part Number: AC103253 Adjustments: Zero and Span field adjustments, non-interacting. Time Constant: 50 seconds in slow moving air. Connections: Screw terminals (22-14 AWG wire).

Specification and order options

Weight: 6 lbs (2.02 kg). AH73 Model number AH71Industrial grade humidity transmitter withoptional temperature transmitter, CH106 connection head, display NAAH72Industrial grade humidity transmitter withoptional temperature transmitter, XIHMF connection head, display NAAH73Industrial grade humidity transmitter withoptional temperature transmitter, XIHMFG connection head, display available Min. output current: AH71_2.84 lbs (1.29 kg). AH72_, AH73_4.4 3.8 mA. Max. output current: 22 mA. Filter: 6 0 micron stainless-steel sintered filter(replacement P/N : AC103512) Transmitter entity parameters: Factory Mutual Approvals: V Explosionproof with intrinsically safe sensor: Suitable for the following hazardous area locations: Class I, Division 1, 2, Groups B, C, D Class II, Division 1, 2, Groups E, F, G Class III, Division 1, 2Intrinsically safe installation: Suitable for the following hazardous area locations: Class I, Division 1, 2, Groups A, B, C, D Class II, Division 1, 2, Groups E, F, G Class III, Division 1, 2 Class I, Zone 0, AEx ia IIC T4 1 Probe diameter 1=0.375" 1 Process threads 1=
1/2 " NPT2=G
1/2 P3 Conduit thread P3=
1/2 " NPTP4=
3/4 " NPT L120 Probe length L60=6"L120=12" T1 Filter type T1=Sintered stainless steelT2=Slotted stainless steel HT480 Transmitter model number HT480=Explosionproof with intrinsically safe sensor (transmitter code NT only)HT490=Intrinsically safe
max = 28 volts; I
max = 100 mA; C
i = 0.037 µ F and L
i = 0 mH. Transmitter ranges:
HVAC SENSORS Code Transmitter range N Display C=Display, metric units (AH73_series only)F=Display, English units (AH73_series only) N=No display (AH71_ and AH72_ series only) NT No temperature transmitter EN -20°Fto140°F S 0°Fto100°F 1 Signal output A 20°Fto120°F 1=4 to 20mA BI 30°Fto130°F N25 Calibration accuracy (humidity transmitter)N25±2.5% from 10% to 80% (25°C) with NIST certificateS25:±2.5% from 10% to 80% (25°C) N 32°Fto122°F H 40°Fto90°F S Temperature transmitter range from table

Specify and order products at:

AH7311P3L120T1HT480N1N25S = Sample part number

www.minco.com/sensors_config

Specifications subject to change

|

Page 9-11
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 101 p.101
page 102 p.102
page 103 p.103
page 104 p.104
page 105 p.105
page 106 p.106
page 107 p.107
page 108 p.108
page 109 p.109
page 110 p.110
page 111 p.111
page 112 p.112
page 113 p.113
page 114 p.114
page 115 p.115
page 116 p.116
page 117 p.117
page 118 p.118
page 119 p.119
page 120 p.120
page 121 p.121
page 122 p.122
page 123 p.123
page 124 p.124
page 125 p.125
page 126 p.126
page 127 p.127
page 128 p.128
page 129 p.129
page 130 p.130
page 131 p.131
page 132 p.132
page 133 p.133
page 134 p.134
page 135 p.135
page 136 p.136
page 137 p.137
page 138 p.138
page 139 p.139
page 140 p.140
page 141 p.141
page 142 p.142
page 143 p.143
page 144 p.144
page 145 p.145
page 146 p.146
page 147 p.147
page 148 p.148
page 149 p.149
page 150 p.150
Pages:
1-50
51-100
101-150
151-164
pdf-page pdf di En 2008-12-49-05