Standard Design Recommendations
Holes
G e n e r al r e quir e m e nt s for p a d s , a cc ess ho lesa Vi as nd a nnu la r rin gs >
Minco can provide circuits with covers that have noaccess holes exposing the vias (called 'tented vias').
Minco can also provide blind and buried vias in multi-
layer and rigid-flex circuits. Blind vias connect the top
or bottom conductor layer to adjoining layers, but the
via does not extend through all layers. A buried via
only connects internal layers and is not exposed in the
finished circuit. Blind and buried vias increase circuit
cost, but they free up space for additional conductors
on the non-drilled layers. F ea tur e Sin gle - la y e r Dou ble - la y e r Mu l ti la y e r Pad * 0.060" (1.5mm) + t 0.030" (0.76mm) + t Outer pad: 0.030" (0.76mm) + t
Inner pad: 0.025" (0.63mm) + t Major
access
hole * 0.050" (1.3mm) + t 0.030" (0.76mm) + t 0.030" (0.76mm) + t Minoraccess
hole‡ 0.015" (0.38mm) + t 0.015" (0.38mm) + t 0.015" (0.38mm) + t T ented ViaB l ind Via
Buried t = nominal through-hole diameter. * Pad and major access hole design requirements are based on typical annular ring requirements of 0.015" (0.38mm) minimum for a single-layer,
0.005" (0.13mm) minimum for all external layers, and 0.002" (0.05mm) mini-
mum for multilayer innerlayers.‡ Customer must allow tangency (see the Glossary for a definition oftangency).For more information on access holes (major and minor) annular ring, pads,and thruholes, see the Glossary on pages 28 – 30. Via Thruho le or Throu g h-ho le >
Plated through-holes (PTH) connect together the top, bottom,and any required internal conductor layers. PTHs are drilled
oversize to accommodate the thickness of the copper plating
that will cover the entire barrel of the hole as well as the surface
of the outer pads. Exterior pads may be plated along with the
entire foil surface or selectively plated just at the PTH site. l arRing Access Ho l eAnnu T hrough-Ho l e T hrough Ho l eOuter PadInner Major Access Ho l e Pad P l ated WiringHo l e Minor Access Ho l e Stiff e n e r ho les >
Stiffener holes should be a minimum of 0.015" (0.38mm) indiameter larger than the access hole. It is better if the access
hole underneath the stiffener hole is a minor access hole in
order to increase the stiffener web between holes and to prevent potential solder wicking between the stiffener and the
circuit. The customer must allow tangency. Round stiffener holes
are less expensive than slotted stiffener holes, and as mentioned
before, thinner stiffener material (less than 0.031"/0.79mm) is
less expensive to process. 16