RPS-409A-IS2 - 1

Intrinsically Safe ultrasonic sensor with ANZEx, ATEX, cUL, & IECEx approvals for use in Hazardous (Classified) Locations. • Intrinsically Safe • Various Sensing Ranges • Temperature Compensation • Wide Temperature Range • LED Indicator • Analog Voltage Output • PPS Enclosure • Sync/Tx Input Line IECEx The RPS-409A-IS2 is an intrinsically safe analog ultrasonic sensor available in a variety of ranges. The RPS-409A-IS2 sensors can be used in hazardous gas or dust environments classified as Zone 0, 1, 2, 20, 21, or 22 for ATEX/IECEx, and Class I, II, or III for UL/cUL when used with approved intrinsic safety barrier(s). See the RPS-409A-IS2 User Manual and Control Drawing No. Ex05021114 for further information on installation in hazardous locations. The sensor is self-contained in a 30mm barrel style enclosure, and is powered by 16 - 30 V dc with reverse polarity protection. The RPS-409A-IS2 has a short circuit protected 0 - 10 V dc analog output. The analog voltage is a fixed volts per inch based on 0.00V @ 0" the maximum range of the unit. For example when using the RPS-409A-80-IS2, the output is a linear 0.125 V per inch. A target placed 10 inches from the sensor will result in an output of 1.25 V or a target placed at 80 inches from the sensor will result in an output of 10 V. The RPS-409A-IS2 has built-in temperature compensation to provide accurate readings throughout the entire operating temperature range. An LED indicator is provided. The LED is green with no target detected and changes to red when a target is detected. The sensor is completely sealed and connection must be made with a cable having a rating of IP67 or greater. In addition to the analog output line the sensor also has a Sync/Tx line. This line can be used for connecting multiple sensors together (Sync) to prevent cross talk, or to control when the sensor transmits (Tx). The RPS-409A-IS2 is designed to take advantage of today's PLC and computer analog input cards. The numerical values that are programmed into the PLC or computer will determine the zero and span of the sensor.

Open the catalog to page 1
RPS-409A-IS2 - 2

Beam Diameter Entity Parameters: Power Input: 16 - 30VDC Reverse Polarity Protected (A minimum of 24VDC must be applied to the safety barrier) Input Current: 24mA maximum with 24VDC applied to the safety barrier Output:     Ambient Temperature: Analog Voltage Output 0 - 10V (Load 100k Ohms to infinity) Short Circuit Protected Enclosure Material: Polyphenylene Sulfide (PPS) Enclosure with PPS and PTFE sensing face Australia and New Zealand - ANZEx 13.3010X Ex ia I Ma, Ex ia IIC T4 Ga, Ex ia IIIC T101°C Da Canada and USA - UL/cUL File # E226209 CL I, GPS A,B,C,D; CL II, GPS E,F,G; and CL III...

Open the catalog to page 2

All Migatron catalogs and technical brochures

  1. RPS-409A-IS3

    2 Pages

  2. RPS-409A-2P

    2 Pages

  3. LCU-40APW

    2 Pages

  4. RPS-409A-2P

    2 Pages

  5. RPS-401/426

    2 Pages

  6. RPS-409A

    2 Pages

  7. RPS-4000

    4 Pages

  8. RPS-150A

    2 Pages