RPS-300-14-T, RPS-300-36-T Controller With Remote Sensing Head
2Pages

{{requestButtons}}

Catalog excerpts

RPS-300-14-T, RPS-300-36-T Controller With Remote Sensing Head - 1

RPS-300-14-T RPS-300-36-T Various Sensing Ranges Narrow Sensing Beam High Frequency Isolated Form C Relay Output Small Electronic Controller Sealed Transducer Small Remote Transducer The RPS-300-T is a high frequency, sealed transducer unit best suited for environments where chemicals or weld splatter is a problem. The transducer head is constructed of a seamless Teflon body and sensing face. The remote transducer allows for mounting of the sensor head in cramped spaces while the controller is out of the way. The ranging and proximity modes provide the versatility of simple detection, or actual distance measuring. The isolated form C relay furnishes N.O. and N.C. outputs, and with the addition of the RPS-500 card various analog outputs are supplied. The RPS-300-T sensor operates at a frequency of 180kHz for the 14" and 36" ranges. This sensor has a narrow sensing beam. Sensing ranges available for the RPS-300-T include 4" to 14", 5" to 36". Mounting flanges, LED indicator, ranging potentiometer and 6-ft. transducer cable are included. Optional cable lengths are available. Proximity Detection Ranging Measurement Proximity Detection Ranging Measurement Proximity detection is the detection of an object in a given range. The detection range of the RPS-300-T is controlled by the "Range Control" potentiometer located on the front cover of the controller. Any object within the desired range is detected, while objects out of range are ignored. The detect point is independent of size, material, and reflectivity. The Proximity Option is denoted by the part number RPS-300-14-T. With the addition of the RPS-500 card, Analog outputs of 0-10 VDC and 4-20 mA are provided. Precise distances of an object moving to and from the transducer are measured via time intervals between transmitted and reflected bursts of ultrasonic sound. The example shows a target detected at 6 inches from the transducer and moving to 10 inches. The distance change is continuously calculated and outputted. Ranging Option is indicated by following the part number with (-500). (Example: RPS-300-36-T-500)

Open the catalog to page 1
RPS-300-14-T, RPS-300-36-T Controller With Remote Sensing Head - 2

Specifications: Operational Range: Power Input: * Only 120VAC or 24VDC with 500 Analog card. Input Current: Input with 500 card: Ambient Temperature: Controller : Transducer Housing: Metal Enclosed Teflon Isolated Form C Relay .5 Amp Maximum at 120VAC 12VDC Logic Signal 0 - 10VDC, 4 - 20 mA Analog Outputs with Zero, Span, Sample, and Hold controls. Output with 500 card: Transducer Frequency: Response Time: Weight of Controller: Weight of Transducer: NEAR DISTANCE DISPLAY FAR SAMPLE & HOLD SPAN ZERO INVERTING SWITCH A - Angle of Tilt B - Beam Spread C - Wiring Diag.- For RPS-300 D - Wiring...

Open the catalog to page 2

All Migatron catalogs and technical brochures

  1. RPS-409A-IS3

    2 Pages

  2. RPS-409A-2P

    2 Pages

  3. LCU-40APW

    2 Pages

  4. RPS-409A-2P

    2 Pages

  5. RPS-401/426

    2 Pages

  6. RPS-409A

    2 Pages

  7. RPS-409A-IS2

    2 Pages

  8. RPS-4000

    4 Pages

  9. RPS-150A

    2 Pages