M-1000 Control Meter
3Pages

{{requestButtons}}

Catalog excerpts

M-1000 Control Meter - 1

M-1000 Features Analog Input Sealed Front Panel (Nema) 4 Dual Sensor Control Program Lock Access Code Temp. Compensation Thickness Measuring The M-1000 analog controller is a multipurpose dual sensor controller with a wide range of uses in the process control field. It was designed to work with any of Migatron's analog output sensors as well as a temperature probe for temperature compensation. Its easy program modes allow instruction entry and review of previously programmed values. It accepts a standard 0-20 mA, 4-20 mA, 0-5V, 2-10V, 0-10V analog input. The microcontroller digitally scales the inputs with near and far scaling points, then this information is displayed on a 4 1/2 digit digital display. This attribute is also contained in an optional second channel input for added expandability.The controller can also supply 24 volts up to 110 mA to the sensors. The outputs consist of four solid state relays for use as outside limit monitors. These outputs can be programed as either normally open or normally closed and can switch 2-130 VAC or VDC 100 mA DC or 50 mA AC continuous. A RS485 serial communications port is also supplied. Communication can take place for baud rates of 300, 1200, 2400, 4800, and 9600. Each controller can be configured to transmit standard ASCII code up to a maximum distance of 10,000 feet. The M-1000 samples its inputs at a rate of 25 times per second, and includes autozeroing. Its analog to digital converter is accurate to +- .05 mV and its converter is also rated as having a drift rating of 50 ppm per degree Celsius. The M-1000 is powered by 120 VAC, 8 watts and all of the inputs and outputs are tightly secured with reliable screw clamp cable connectors. Alarm high set point SP1 Ultrasonic Sensor METER CONTROL PANEL LEVEL CONTROL 1) 4 1/2 Digit Display, used to display the data to the user, and to display the set values while programing. 2) Relay Indicator L.E.D.s, to indicate which outputs are on, and flicker when in the program state. 3) Program Mode selector when pressed displays program choices. 4) L.E.D. Indicators for channel 1 and channel 2. 5) Up Cursor increases numerical value. 6) Down Cursor decreases numerical value. 7) Enter button puts program choices into memory. WIRING DIAGRAM MOUNTING DIMENSIONS

Open the catalog to page 1
M-1000 Control Meter - 2

SINGLE CHANNEL PROGRAMING 1. Wire power to terminals marked 115 VAC. 2. Wire sensor to terminals marked channel 1. 3. Wire temperature probe to terminals marked channel three if temperature compensation is desired. 4. To program enter program code "58", or enter "25" to go directly to steps 16 & 17. Pr 00 Pr 58 ENTER MODE 5. Six factory presets are avaliable. Factory preset 1 4 to 40" with 4 - 20mA input, 2 8 to 80" with 4 - 20mA input, 3 4 to 40" with 0 - 10volt input, 4 8 to 80" with 0 - 10volt input, 5 0 to 20 to display current input, 6 0 to 10 to display voltage input. If one of these...

Open the catalog to page 2
M-1000 Control Meter - 3

DUAL CHANNEL PROGRAMING 1. Wire power to terminals marked 115 VAC. 2. Wire sensors to terminals marked channel 1 and 2. 3. Wire temperature probe to terminals marked channel three if temperature compensation is desired. 4. To program enter program code "58", or enter "25" to go directly to steps 16, 17, 18. MODE 5. Six factory presets are available. Factory preset 1 4 to 40" with 4 - 20mA input, 2 8 to 80" with 4 - 20mA input, 3 4 to 40" with 0 - 10volt input, 4 8 to 80" with 0 - 10volt input, 5 0 to 20 to display current input, 6 0 to 10 to display voltage input. If one of these is not...

Open the catalog to page 3