zws - microsonic
P. 01
zws - microsonic
P. 02
Pages:
zws - microsonic


See other catalogues for microsonic

Text version of the page
Sensor adjustment with Teach-in procedure S e t d e t e c t p o i n t Place object at position . Pr ess push-button for about 3 s until LEDs flash simultaneously both LEDs: flash mutually Pr ess push-button for about 1 s Set window mode Place object at position . Pr ess push-button for about 3 s until LEDs flash simultaneously both LEDs: Place object at position . Pr ess push-button for about 1 s flash mutually Set two way r eflective barrier Set NOC/NCC Enable/disable T each-in push-button Switch of f power supply Place r eflector at position . Pr ess push-button for about 3 s until LEDs flash simultaneously Pr ess button for about 13 s until LEDs flash mutually both LEDs: flash mutually Pr ess push-button for about 10 s gr een LED: yellow LED: T o change output characteristic pr ess push-button for about 1 s While pr essing the pushbutton switch on power supply Keep push-button pr essed for about 3 s until both LEDs flash simultaneously flashes on: NOC off: NCC gr een LED: yellow LED: flashes on: push-button enabled off: push-button disabled T o enable/disable T each-in pr ess push-button for about 1 s Reset to factory setting Switch of f power supply While pr essing the pushbutton switch on power supply Keep push-button pr essed for about 13 s until both LEDs stop flashing Normal operating mode W ait for 10 s W ait for 10 s Normal operating mode Operating Instructions zws-15 /CD/QS zws-15 /CE/QS zws-24 /CD/QS zws-24 /CE/QS zws-25 /CD/QS zws-25 /CE/QS zws-70 /CD/QS zws-70 /CE/QS Ultrasonic pr oximity switch with one switched output Pr oduct Description The zws sensor of fers a non-contact measur ement of the distance to an object which must be positioned U l t r a s o n i c S e n s o r s within the sensor’ s detection zone. The switched output is set in dependence of the adjusted detect distance. V ia the push-button, the detect distance and operating mode can be adjusted (teach-in). T wo LEDs indicate operation and the state of the switched output. Safety Notes ‘ Read the operating instructions prior to start-up. ‘ Connection, installation and adjustment works may only be carried out by expert personnel. ‘ No safety component in accor dance with the EU Machine Dir ective Pr oper use zws ultrasonic sensors are used for non-contact detection of objects. Installation ‘ Mount the sensor at the installation site with the aid of the enclosed mounting plate. Maximum tor que: 0,5 Nm Fig. 1: Attachment with mounting plate ‘ Connect a connection cable to the M8 device plug. Fig. 2: Pin assignment with view onto sensor plug and colour coding of the microsonic connection cable Start-Up ‘ Connect the power supply . ‘ Carry out the adjustment in accor dance with the diagram. Factory Setting ‘ Operation with one detect point ‘ Switched output on NOC ‘ Detect points at operating range 1 3 colour +U B -U B brown blue 4 2 D Sync black white 1 4 3 2 Operating modes Thr ee operating modes ar e available for the switched output: ‘ Operation with one detect point The switched output is set if the object falls below the set detect point. ‘ W indow mode The switched output is set if the object is within the set window mar - gins. ‘ T wo-way r eflective barrier The switched output is set if the object is between sensor and r eflector . Synchr onization Y ou can synchr onize as many sensors as you like. ‘ Apply a squar e-wave signal to the sync-input with pulse width t i and r epetition rate t p (Fig.3 and technical data). A high level on the sync-input will deactivate the sensor . Fig.3: External synchronization signal Checking operation mode ‘ In normal mode shortly pr ess the push-button. T h e g r e e n L E D s t o p s s h i n i n g f o r o n e s e c o n d , t h e n i t w i l l s h o w t h e c u r r e n t o p e r a t i n g m o d e : 1 x flashing = operation with one switching point 2 x flashing = window mode 3 x flashing = reflective barrier After a br eak of 3 s the gr een LED shows the output function: 1 x flashing = NOC 2 x flashing = NCC Maintenance micr osonic sensors ar e maintenancefr ee. In case of excess caked-on dirt we r ecommend cleaning the white sensor surface Notes ‘ The zws sensor has a blind zone, within which distance measur ements ar e not possible. ‘ I n t h e n o r m a l o p e r a t i n g m o d e , a n i l - l u m i n a t e d y e l l o w L E D s i g n a l s t h e switched output is switched thr ough. ‘ T h e s t a n d a r d s e n s o r h a s n o t e m p e - r a t u r e c o m p e n s a t i o n . ‘ I f t h e o b j e c t t o b e s e n s e d m o v e s i n t o t h e d e t e c t i o n a r e a f r o m t h e s i d e , t h e s w i t c h i n g d i s t a n c e s h o u l d b e s e t 8 - 1 0 % f u r t h e r t h a n t h e d e - s i r e d s w i t c h p o i n t t o o b t a i n a r e l i - a b l e o b j e c t d e t e c t i o n . I f t h e o b j e c t m o v e s t o w a r d s t h e s e n s o r ( e . g . l e v e l c o n t r o l ) t h e d e - t e c t p o i n t c a n b e t a u g h t t o t h e a c - t u a l d i s t a n c e a t w h i c h t h e s e n s o r h a s t o s w i t c h t h e o u t p u t . Sensor disabled Sensor disabled Start +U B -U B t i t p Set switched output Further settings

pageCatalog pdf di En 2012-05-22-31