Sensor adjustment with Teach-in procedure
S e t d e t e c t p o i n t
Place object at position .
Pr ess push-button for about
3 s until LEDs flash
simultaneously
both LEDs: flash
mutually
Pr ess push-button for
about 1 s
Set window mode
Place object at position .
Pr ess push-button for about
3 s until LEDs flash
simultaneously
both LEDs:
Place object at position .
Pr ess push-button for
about 1 s
flash
mutually
Set two way r eflective
barrier Set NOC/NCC Enable/disable T each-in
push-button
Switch of f power supply
Place r eflector at position .
Pr ess push-button for about
3 s until LEDs flash
simultaneously
Pr ess button for about 13 s
until LEDs flash
mutually
both LEDs: flash
mutually
Pr ess push-button for
about 10 s
gr een LED:
yellow LED:
T o change output characteristic
pr ess push-button
for about 1 s
While pr essing the pushbutton
switch on power
supply
Keep push-button pr essed
for about 3 s until both
LEDs flash simultaneously
flashes
on: NOC
off: NCC
gr een LED:
yellow LED:
flashes
on: push-button
enabled
off: push-button
disabled
T o enable/disable T each-in
pr ess push-button
for about 1 s
Reset to factory setting
Switch of f power supply
While pr essing the pushbutton
switch on power
supply
Keep push-button pr essed
for about 13 s until both
LEDs stop flashing
Normal operating mode
W ait for 10 s W ait for 10 s
Normal operating mode
Operating Instructions
zws-15 /CD/QS zws-15 /CE/QS
zws-24 /CD/QS zws-24 /CE/QS
zws-25 /CD/QS zws-25 /CE/QS
zws-70 /CD/QS zws-70 /CE/QS
Ultrasonic pr oximity switch with
one switched output
Pr oduct Description
The zws sensor of fers a non-contact
measur ement of the distance to an
object which must be positioned
U l t r a s o n i c S e n s o r s
within the sensor s detection zone.
The switched output is set in dependence
of the adjusted detect distance.
V ia the push-button, the detect distance
and operating mode can be
adjusted (teach-in). T wo LEDs indicate
operation and the state of the
switched output.
Safety Notes
‘ Read the operating instructions
prior to start-up.
‘ Connection, installation and
adjustment works may only be
carried out by expert personnel.
‘ No safety component in
accor dance with the EU Machine
Dir ective
Pr oper use
zws ultrasonic sensors are used for
non-contact detection of objects.
Installation
‘ Mount the sensor at the installation
site with the aid of the
enclosed mounting plate.
Maximum tor que: 0,5 Nm
Fig. 1: Attachment with mounting plate
‘ Connect a connection cable to the
M8 device plug.
Fig. 2: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cable
Start-Up
‘ Connect the power supply .
‘ Carry out the adjustment in
accor dance with the diagram.
Factory Setting
‘ Operation with one detect point
‘ Switched output on NOC
‘ Detect points at operating range
1
3
colour
+U B
-U B
brown
blue
4
2
D
Sync
black
white
1
4
3
2
Operating modes
Thr ee operating modes ar e available
for the switched output:
‘ Operation with one detect point
The switched output is set if the object
falls below the set detect point.
‘ W indow mode
The switched output is set if the object
is within the set window mar -
gins.
‘ T wo-way r eflective barrier
The switched output is set if the object
is between sensor and r eflector .
Synchr onization
Y ou can synchr onize as many sensors
as you like.
‘ Apply a squar e-wave signal to the
sync-input with pulse width t i and
r epetition rate t p (Fig.3 and
technical data).
A high level on the sync-input will
deactivate the sensor .
Fig.3: External synchronization signal
Checking operation mode
‘ In normal mode shortly pr ess the
push-button.
T h e g r e e n L E D s t o p s s h i n i n g f o r o n e
s e c o n d , t h e n i t w i l l s h o w t h e c u r r e n t
o p e r a t i n g m o d e :
1 x flashing = operation with one
switching point
2 x flashing = window mode
3 x flashing = reflective barrier
After a br eak of 3 s the gr een LED
shows the output function:
1 x flashing = NOC
2 x flashing = NCC
Maintenance
micr osonic sensors ar e maintenancefr
ee. In case of excess caked-on dirt
we r ecommend cleaning the white
sensor surface
Notes
‘ The zws sensor has a blind zone,
within which distance measur ements
ar e not possible.
‘ I n t h e n o r m a l o p e r a t i n g m o d e , a n i l -
l u m i n a t e d y e l l o w L E D s i g n a l s t h e
switched output is switched
thr ough.
‘ T h e s t a n d a r d s e n s o r h a s n o t e m p e -
r a t u r e c o m p e n s a t i o n .
‘ I f t h e o b j e c t t o b e s e n s e d m o v e s
i n t o t h e d e t e c t i o n a r e a f r o m t h e
s i d e , t h e s w i t c h i n g d i s t a n c e s h o u l d
b e s e t 8 - 1 0 % f u r t h e r t h a n t h e d e -
s i r e d s w i t c h p o i n t t o o b t a i n a r e l i -
a b l e o b j e c t d e t e c t i o n .
I f t h e o b j e c t m o v e s t o w a r d s t h e
s e n s o r ( e . g . l e v e l c o n t r o l ) t h e d e -
t e c t p o i n t c a n b e t a u g h t t o t h e a c -
t u a l d i s t a n c e a t w h i c h t h e s e n s o r
h a s t o s w i t c h t h e o u t p u t .
Sensor disabled Sensor disabled
Start
+U B
-U B
t i t p
Set switched output Further settings
|
|