Catalog excerpts
EVERY THING ULTRA SONIC Extract from our online catalogue: wms ultrasonic sensors Current to: 2023-1 1-13 microsonic GmbH / PhoenixseestraRe 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de microsonic® is a registered trademark of microsonic GmbH. All rights reserved.
Open the catalog to page 1The wms sensors are designed for use in microprocessor controllers with signal evaluation performed by the customer. Trigger input for control of the ultrasonic transmitter Echo output for customer-provided evaluation in the controller 5 detection ranges with a measurement range of 30 mm to 8 m
Open the catalog to page 2Description The wms sensors require connection to the customer's own control and signal evaluation equipment. wms - the inexpensive alternative to a self-contained sensor when the sensor must be controlled by the customer's system. A microprocessor control is normally required for this. The "transmitter" signal input briefly has to be set to -UB by the control unit via an open-collector circuit. As a result, an the wms sensor emits a sound pulse for the time of this signal. The "echo" signal output subsequently transmits all echo signals received depending on their duration as 1 bit values...
Open the catalog to page 3detection zone scale drawing JLTL echo output measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range reproducibility accuracy 30 - 350 mm cylindrical M18 sensor for evaluators echo propagation time measurement 320 kHz 30 mm 250 mm 350 mm ± 0.15 % temperature drift 0.17 %/K electrical data operating voltage Ub 10 - 30 V d.c., reverse polarity protection no-load current consumption < 30 mA type of connection 4-pin M12 initiator plug
Open the catalog to page 4The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
Open the catalog to page 6detection zone scale drawing JLTL echo output measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range reproducibility accuracy 30 - 350 mm cylindrical M18 sensor for evaluators stainless steel version echo propagation time measurement 320 kHz 30 mm 250 mm 350 mm ± 0.15 % temperature drift 0.17 %/K electrical data operating voltage UB 10 - 30 V d.c., reverse polarity protection no-load current consumption < 30 mA type of connection 4-pin M12 initiator plug
Open the catalog to page 7The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
Open the catalog to page 9scale drawing JLTL echo output measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range reproducibility accuracy 65 - 600 mm cylindrical M30 sensor for evaluators echo propagation time measurement 400 kHz 65 mm 350 mm 600 mm ± 0.15 % temperature drift 0.17 %/K electrical data operating voltage Ub 10 - 30 V d.c., reverse polarity protection no-load current consumption < 30 mA type of connection 4-pin M12 initiator plug
Open the catalog to page 10The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.
Open the catalog to page 12scale drawing JLTL echo output measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range reproducibility accuracy 65 - 600 mm cylindrical M30 sensor for evaluators high chemical resistance echo propagation time measurement 400 kHz 65 mm 350 mm 600 mm ± 0.15 % temperature drift 0.17 %/K electrical data operating voltage UB 9 - 30 V d.c., reverse polarity protection no-load current consumption < 30 mA type of connection 4-pin M12 initiator plug
Open the catalog to page 13outputs output 1 signal output echo pnp: Imax = 10 mA (signal output echo) inputs recommended transmitted pulse length 80 ps recommended measuring cycle time 12 ms description controlled by open collector (npn), Ic > 3 mA, Uce > 30 V input 1 signal input - transmitter housing material ultrasonic transducer class of protection to EN 60529 operating temperature storage temperature weight brass sleeve, nickel-plated, plastic parts, PBT polyurethane foam, epoxy resin with glass contents IP 65 -20°C to +70°C -40°C to +85°C 200 g no no yes yes no high chemical resistance technical...
Open the catalog to page 14scale drawing JLTL echo output measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range reproducibility accuracy 200 - 2.000 mm cylindrical M30 sensor for evaluators echo propagation time measurement 200 kHz 200 mm 1,300 mm 2,000 mm ± 0.15 % temperature drift 0.17 %/K electrical data operating voltage Ub 10 - 30 V d.c., reverse polarity protection no-load current consumption < 30 mA type of connection 4-pin M12 initiator plug
Open the catalog to page 15outputs output 1 signal output echo PnP: 1 max — 10 mA (signal output echo) inputs recommended transmitted pulse length 150 ps recommended measuring cycle time 20 ms description controlled by open collector (npn), IC > 3 mA, UCE > 30 V input 1 signal input - transmitter housing material ultrasonic transducer class of protection to EN 60529 operating temperature storage temperature weight further versions brass sleeve, nickel-plated, plastic parts, PBT polyurethane foam, epoxy resin with glass contents IP 65 -25°C to +70°C -40°C to +85°C 200 g stainless steel cable connection (on request)...
Open the catalog to page 16scale drawing JLTL echo output measuring range design operating mode ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range reproducibility accuracy 350 - 5.000 mm cylindrical M30 sensor for evaluators echo propagation time measurement 120 kHz 350 mm 3,400 mm 5,000 mm ± 0.15 % temperature drift 0.17 %/K electrical data operating voltage Ub 10 - 30 V d.c., reverse polarity protection no-load current consumption < 30 mA type of connection 4-pin M12 initiator plug
Open the catalog to page 17All Microsonic catalogs and technical brochures
-
crm+25/D/TC/E
75 Pages
-
hps+25/DIU/TC/E/G1
44 Pages
-
mic+ ultrasonic sensors
191 Pages
-
bks ultrasonic edge sensors
13 Pages
-
bks+ ultrasonic edge sensors
10 Pages
-
crm+ ultrasonic level sensors
75 Pages
-
esp-4 label/splice sensor
17 Pages
-
hps+ ultrasonic level sensors
44 Pages
-
LCA-2
11 Pages
-
lcs ultrasonic sensors
33 Pages
-
lpc+ ultrasonic sensors
77 Pages
-
mic ultrasonic sensors
46 Pages
-
mic+ ultrasonic sensors
191 Pages
-
nano M12 ultrasonic sensor
19 Pages
-
nero ultrasonic proximity switch
100 Pages
-
pico+ ultrasonic sensors
78 Pages
-
pico+TF ultrasonic level sensors
41 Pages
-
sks ultrasonic proximity switch
18 Pages
-
ucs ultrasonic sensors
17 Pages
-
zws ultrasonic sensors
79 Pages
-
cube ultrasonic sensors
33 Pages
-
Online Catalogue ultrasonic sensors