Catalog excerpts
EVERY THING ULTRA SONIC Extract from our online catalogue: pico+ ultrasonic sensors Current to: 2023-1 1-13 microsonic GmbH / PhoenixseestraRe 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de microsonic® is a registered trademark of microsonic GmbH. All rights reserved.
Open the catalog to page 1pico+ the "little guy" that can do it all: 4 ranges, 3 output signals, 2 housing variants and IO-Link interface. Variant with 90° angled head IO-Link interface Automatic synchronisation and multiplex operation UL Listed to Canadian and US safety standards Improved temperature compensation Smart Sensor Profiles for support of the new industry standard for simultaneous operation of up to ten sensors in close quarters adjustment to working conditions within 120 seconds more transparency between IO-Link Devices 1 Push-Pull switching output 4 detection ranges with a measurement range of 20 mm to...
Open the catalog to page 2Description The pico+ ultrasonic sensors are a compact series with M18 threaded sleeves and a housing length of only 41 mm. In addition to the variants with an axial beam direction, there is also a housing variant with a 90° angled head and radial beam direction. With four detection ranges from 20 mm to 1.3 m and three different output stages, this sensor family covers a wide range of applications. Sensors with the Push-Pull output stage support SIO and IO link modes. Sensors with analogue output are optionally available with 4–20 mA current output or 0–10 V voltage output. In SIO mode,...
Open the catalog to page 3Teach-in of a switching point Teach-in of a two-way reflective barrier with a fixed reflector Apply +UB to pin 5 for about 3 seconds Then apply +UB to pin 5 again for about 10 seconds Teach-in of a two-way reflective barrier Place object at the near edge of the window (1) Apply +UB to pin 5 for about 3 seconds Then move the object to the far edge of the window (2) Then apply +UB to pin 5 again for about 1 seconds
Open the catalog to page 4Teach-in of an analogue characteristic or a window with two switching points NCC/NOC and rising/falling analogue characteristic curve can also be set via pin 5. One green and one yellow LED indicate the state of the output and support microsonic Teach-in. LinkControl optionally permits the extensive parameterisation of pico+ sensors. The LCA-2 LinkControl adapter , which is available as an accessory, can be used to connect pico+ sensors to the PC. Sensor connected to the PC via LCA-2 for programming Easy to synchronise A number of pico+ sensors can be run closely packed in applications...
Open the catalog to page 5If more than 10 sensors must be synchronised, this can be carried out with the SyncBox1 , which is available as an accessory. In instances of where a number of sensors are run at an IO-Link master, then the master's function is to assume synchronisation. Synchronised sensor cell in glass bottle production Updated to IO-Link version 1.1 The pico+ sensors with the extension „/A” in the order name are updated to IO-Link version 1.1 and support the Smart Sensor Profile. Please note that these sensor with the updated IO-Link version do not support IO-Link version 1.0 any longer. For example, when...
Open the catalog to page 6scale drawing measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 20 - 250 mm cylindrical M18 analogue distance measurements narrow sound field UL Listed echo propagation time measurement 380 kHz 20 mm 150 mm 250 mm 0.069 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 10 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug
Open the catalog to page 7The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. pico+ ultrasonic sensors
Open the catalog to page 9measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 20 - 250 mm cylindrical M18 analogue distance measurements 90° angular head narrow sound field UL Listed echo propagation time measurement 320 kHz 20 mm 150 mm 250 mm 0.069 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 10 - 30 V d.c., reverse polarity protection type of connection 5-pin M12 initiator plug
Open the catalog to page 10The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. pico+ ultrasonic sensors
Open the catalog to page 12scale drawing measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 20 - 250 mm cylindrical M18 analogue distance measurements narrow sound field UL Listed echo propagation time measurement 380 kHz 20 mm 150 mm 250 mm 0.069 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 15 V bis 30 V DC, verpolfest no-load current consumption < 40 mA type of connection 5-pin M12 initiator plug
Open the catalog to page 13The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. pico+ ultrasonic sensors
Open the catalog to page 15scale drawing measuring range design operating mode particularities ultrasonic-specific means of measurement transducer frequency blind zone operating range maximum range resolution reproducibility accuracy 20 - 250 mm cylindrical M18 analogue distance measurements 90° angular head narrow sound field UL Listed echo propagation time measurement 320 kHz 20 mm 150 mm 250 mm 0.069 mm ± 0.15 % ± 1 % (temperature drift internally compensated) electrical data operating voltage UB 15 V bis 30 V DC, verpolfest no-load current consumption < 40 mA type of connection 5-pin M12 initiator plug
Open the catalog to page 16All Microsonic catalogs and technical brochures
-
crm+25/D/TC/E
75 Pages
-
hps+25/DIU/TC/E/G1
44 Pages
-
mic+ ultrasonic sensors
191 Pages
-
bks ultrasonic edge sensors
13 Pages
-
bks+ ultrasonic edge sensors
10 Pages
-
crm+ ultrasonic level sensors
75 Pages
-
esp-4 label/splice sensor
17 Pages
-
hps+ ultrasonic level sensors
44 Pages
-
LCA-2
11 Pages
-
lcs ultrasonic sensors
33 Pages
-
lpc+ ultrasonic sensors
77 Pages
-
mic ultrasonic sensors
46 Pages
-
mic+ ultrasonic sensors
191 Pages
-
nano M12 ultrasonic sensor
19 Pages
-
nero ultrasonic proximity switch
100 Pages
-
pico+TF ultrasonic level sensors
41 Pages
-
sks ultrasonic proximity switch
18 Pages
-
ucs ultrasonic sensors
17 Pages
-
wms ultrasonic distance sensors
20 Pages
-
zws ultrasonic sensors
79 Pages
-
cube ultrasonic sensors
33 Pages
-
Online Catalogue ultrasonic sensors
172 Pages